{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,9]],"date-time":"2026-07-09T03:32:05Z","timestamp":1783567925027,"version":"3.55.0"},"reference-count":31,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"10","license":[{"start":{"date-parts":[[2025,10,1]],"date-time":"2025-10-01T00:00:00Z","timestamp":1759276800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec>\n            <jats:title>Background:<\/jats:title>\n            <jats:p>Direct-to-implant (DTI) breast reconstruction often uses soft tissue support to improve outcomes and reduce implant migration. Synthetic meshes, such as TIGR Matrix, have emerged as potential alternatives to biological materials due to lower costs and complication rates. This study reviewed early outcomes using TIGR Matrix in immediate DTI reconstruction.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>A retrospective chart review was conducted on patients who underwent implant-based reconstruction with TIGR Matrix between November 2023 and June 2024 across 2 institutions. Inclusion criteria included DTI reconstruction with at least 6 months of follow-up. Data collected included demographics, oncological and reconstructive details, comorbidities, and postoperative complications. Statistical analysis was performed using MATLAB with <jats:italic toggle=\"yes\">t<\/jats:italic> tests and \u03c7<jats:sup>2<\/jats:sup> tests.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>Seventy-one patients (109 breasts) met inclusion criteria. The cohort included 42.2% nipple-sparing, 40.4% skin-sparing, and 11.0% Goldilocks mastectomies. The mean patient age was 52 years. The mean time to first postoperative follow-up was 8.3 days. Major complications included 6 hematomas (5.5%), 3 seromas (2.8%), 2 infections (1.8%), and 3 explantations (2.8%). Eleven (10.1%) patients required reoperation due to complications including infection, necrosis, or residual disease. Minor complications (delayed wound healing, eschar) were observed in 17.4% of breasts. The overall complication rate excluding minor events was 12.8%.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>TIGR Matrix demonstrates an acceptable early complication profile in DTI breast reconstruction and may serve as a cost-effective alternative to acellular dermal matrices. Additional studies are needed to assess long-term outcomes and comparative effectiveness.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/gox.0000000000007170","type":"journal-article","created":{"date-parts":[[2025,10,1]],"date-time":"2025-10-01T12:03:37Z","timestamp":1759320217000},"page":"e7170","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["Early Outcomes Using TIGR Mesh in Direct-to-Implant Breast Reconstruction"],"prefix":"10.1097","volume":"13","author":[{"given":"Orr","family":"Shauly","sequence":"first","affiliation":[{"name":"Division of Plastics and Reconstructive Surgery, Emory University, Atlanta, GA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Makenna","family":"Ash","sequence":"additional","affiliation":[{"name":"Division of Plastic and Reconstructive Surgery, Emory University School of Medicine, Atlanta, GA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shannon","family":"Su","sequence":"additional","affiliation":[{"name":"Division of Plastic and Reconstructive Surgery, Emory University School of Medicine, Atlanta, GA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tola","family":"Ebunlomo","sequence":"additional","affiliation":[{"name":"Division of Plastic and Reconstructive Surgery, Emory University School of Medicine, Atlanta, GA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Melika","family":"Deaton","sequence":"additional","affiliation":[{"name":"Division of Plastics and Reconstructive Surgery, Emory University, Atlanta, GA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Susan","family":"Doh","sequence":"additional","affiliation":[{"name":"Division of Plastic and Reconstructive Surgery, University Hospitals, Cleveland, OH."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joseph S.","family":"Khouri","sequence":"additional","affiliation":[{"name":"Division of Plastic and Reconstructive Surgery, University Hospitals, Cleveland, OH."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Albert","family":"Losken","sequence":"additional","affiliation":[{"name":"Division of Plastics and Reconstructive Surgery, Emory University, Atlanta, GA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,10]]},"reference":[{"key":"R1-20251001","doi-asserted-by":"crossref","first-page":"256","DOI":"10.3390\/medicina56060256","article-title":"Submuscular and pre-pectoral ADM assisted immediate breast reconstruction: a literature review.","volume":"56","author":"Cuomo","year":"2020","journal-title":"Medicina (Kaunas)"},{"key":"R2-20251001","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1097\/PRS.0b013e3182361fd6","article-title":"A meta-analysis of human acellular dermis and submuscular tissue expander breast reconstruction.","volume":"129","author":"Kim","year":"2012","journal-title":"Plast Reconstr Surg"},{"key":"R4-20251001","doi-asserted-by":"crossref","first-page":"674","DOI":"10.1097\/SAP.0b013e3181dba892","article-title":"The effect of acellular dermal matrix use on complication rates in tissue expander\/implant breast reconstruction.","volume":"64","author":"Lanier","year":"2010","journal-title":"Ann Plast Surg"},{"key":"R5-20251001","doi-asserted-by":"crossref","first-page":"1606","DOI":"10.1097\/PRS.0b013e3181d4fb2a","article-title":"Acellular human dermis implantation in 153 immediate two-stage tissue expander breast reconstructions: determining the incidence and significant predictors of complications.","volume":"125","author":"Antony","year":"2010","journal-title":"Plast Reconstr Surg"},{"key":"R6-20251001","doi-asserted-by":"crossref","first-page":"429","DOI":"10.1097\/PRS.0b013e3181c82d90","article-title":"Implant-based breast reconstruction using acellular dermal matrix and the risk of postoperative complications.","volume":"125","author":"Chun","year":"2010","journal-title":"Plast Reconstr Surg"},{"key":"R7-20251001","doi-asserted-by":"crossref","first-page":"3810","DOI":"10.1007\/s00266-024-03896-4","article-title":"Reviewing outcomes and complications with the use of mesh in breast reduction surgery.","volume":"48","author":"Williams","year":"2024","journal-title":"Aesthetic Plast Surg"},{"key":"R8-20251001","doi-asserted-by":"crossref","first-page":"329","DOI":"10.1097\/PRS.0000000000002331","article-title":"Acellular dermal matrix-assisted direct-to-implant breast reconstruction and capsular contracture: a 13-year experience.","volume":"138","author":"Salzberg","year":"2016","journal-title":"Plast Reconstr Surg"},{"key":"R9-20251001","doi-asserted-by":"crossref","first-page":"1842","DOI":"10.1097\/PRS.0b013e3181f44674","article-title":"Acellular cadaveric dermis decreases the inflammatory response in capsule formation in reconstructive breast surgery.","volume":"126","author":"Basu","year":"2010","journal-title":"Plast Reconstr Surg"},{"key":"R10-20251001","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1093\/asj\/sju014","article-title":"Further evidence that human acellular dermal matrix decreases inflammatory markers of capsule formation in implant-based breast reconstruction.","volume":"35","author":"Leong","year":"2015","journal-title":"Aesthet Surg J"},{"key":"R11-20251001","doi-asserted-by":"crossref","first-page":"957","DOI":"10.1111\/tbj.13113","article-title":"Direct-to-implant breast reconstruction: higher complication rate vs cosmetic benefits.","volume":"24","author":"Gschwantler-Kaulich","year":"2018","journal-title":"Breast J"},{"key":"R12-20251001","doi-asserted-by":"crossref","first-page":"423","DOI":"10.1177\/22925503221141708","article-title":"Trends and early complications in direct-to-implant breast reconstruction: an updated analysis of the ACS-NSQIP database.","volume":"32","author":"Plotsker","year":"2024","journal-title":"Plast Surg (Oakv)"},{"key":"R13-20251001","doi-asserted-by":"crossref","first-page":"92","DOI":"10.1007\/s00266-022-03068-2","article-title":"Direct-to-implant subcutaneous breast reconstruction: a systematic review of complications and patient\u2019s quality of life.","volume":"47","author":"Silva","year":"2023","journal-title":"Aesthetic Plast Surg"},{"key":"R14-20251001","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1097\/SAP.0000000000000742","article-title":"Short-term complications associated with acellular dermal matrix-assisted direct-to-implant breast reconstruction.","volume":"78","author":"Hunsicker","year":"2017","journal-title":"Ann Plast Surg"},{"key":"R15-20251001","doi-asserted-by":"crossref","first-page":"279","DOI":"10.1007\/s00238-019-01603-0","article-title":"Immediate implant reconstruction using absorbable TIGR mesh after nipple-sparing mastectomy.","volume":"43","author":"Quinn","year":"2020","journal-title":"Eur J Plast Surg"},{"key":"R16-20251001","first-page":"e61052","article-title":"Surgical and patient-reported outcomes after mastectomy and implant-based prepectoral reconstruction using TIGR(R) synthetic mesh.","volume":"16","author":"Razdan","year":"2024","journal-title":"Cureus"},{"key":"R17-20251001","doi-asserted-by":"crossref","first-page":"53","DOI":"10.2217\/bmt-2016-0003","article-title":"Immediate implant-based breast reconstruction using the TIGR\u00ae Matrix mesh.","volume":"5","author":"Schrenk","year":"2016","journal-title":"Breast Cancer Manag"},{"key":"R18-20251001","doi-asserted-by":"crossref","first-page":"629","DOI":"10.1097\/PRS.0000000000001570","article-title":"Capsular contracture in implant-based breast reconstruction: examining the role of acellular dermal matrix fenestrations.","volume":"136","author":"Mowlds","year":"2015","journal-title":"Plast Reconstr Surg"},{"key":"R19-20251001","doi-asserted-by":"crossref","first-page":"e6031","DOI":"10.1097\/GOX.0000000000006031","article-title":"A comparison of capsular contracture rates after immediate implant-based breast reconstruction using biologic versus synthetic mesh.","volume":"12","author":"Ferenz","year":"2024","journal-title":"Plast Reconstr Surg Glob Open"},{"key":"R20-20251001","doi-asserted-by":"crossref","first-page":"373","DOI":"10.1097\/00006534-199003000-00006","article-title":"Capsular contracture after breast reconstruction with silicone-gel and saline-filled implants: a 6-year follow-up.","volume":"85","author":"Gylbert","year":"1990","journal-title":"Plast Reconstr Surg"},{"key":"R21-20251001","doi-asserted-by":"crossref","first-page":"1137","DOI":"10.1038\/s41598-020-58094-4","article-title":"Evaluation of capsular contracture following immediate prepectoral versus subpectoral direct-to-implant breast reconstruction.","volume":"10","author":"Sobti","year":"2020","journal-title":"Sci Rep"},{"key":"R22-20251001","doi-asserted-by":"crossref","first-page":"731e","DOI":"10.1097\/PRS.0000000000007384","article-title":"The use of absorbable mesh in implant-based breast reconstruction: a 7-year review.","volume":"146","author":"Faulkner","year":"2020","journal-title":"Plast Reconstr Surg"},{"key":"R23-20251001","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1097\/PRS.0000000000010914","article-title":"Prepectoral two-stage implant-based breast reconstruction with poly-4-hydroxybutyrate for pocket control without the use of acellular dermal matrix: a 4-year review.","volume":"154","author":"Movassaghi","year":"2024","journal-title":"Plast Reconstr Surg"},{"key":"R24-20251001","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1007\/s10029-011-0885-y","article-title":"Three-year results from a preclinical implantation study of a long-term resorbable surgical mesh with time-dependent mechanical characteristics.","volume":"16","author":"Hjort","year":"2012","journal-title":"Hernia"},{"key":"R25-20251001","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1016\/j.cps.2017.08.005","article-title":"The use of TIGR Matrix in breast aesthetic and reconstructive surgery: is a resorbable synthetic mesh a viable alternative to acellular dermal matrices?","volume":"45","author":"Pompei","year":"2018","journal-title":"Clin Plast Surg"},{"key":"R26-20251001","doi-asserted-by":"crossref","first-page":"689","DOI":"10.1080\/17434440.2018.1515625","article-title":"TIGR Matrix for implant-based breast reconstruction: a long-term resorbable mesh.","volume":"15","author":"Cuffolo","year":"2018","journal-title":"Expert Rev Med Devices"},{"key":"R27-20251001","doi-asserted-by":"crossref","first-page":"353","DOI":"10.1016\/j.bjps.2017.09.010","article-title":"Assessing value in breast reconstruction: a systematic review of cost-effectiveness studies.","volume":"71","author":"Sheckter","year":"2018","journal-title":"J Plast Reconstr Aesthet Surg"},{"key":"R28-20251001","doi-asserted-by":"crossref","first-page":"1120","DOI":"10.1007\/s00266-020-01822-y","article-title":"The use of synthetic mesh in reconstructive, revision, and cosmetic breast surgery.","volume":"44","author":"Becker","year":"2020","journal-title":"Aesthetic Plast Surg"},{"key":"R29-20251001","doi-asserted-by":"crossref","first-page":"1678","DOI":"10.1007\/s00266-022-02972-x","article-title":"Risk factors for capsular contracture in alloplastic reconstructive and augmentation mammaplasty: analysis of the National Surgical Quality Improvement Program (NSQIP) database.","volume":"47","author":"Ali","year":"2023","journal-title":"Aesthetic Plast Surg"},{"key":"R30-20251001","doi-asserted-by":"crossref","first-page":"20S","DOI":"10.1097\/PRS.0000000000004351","article-title":"Risk factor analysis for capsular contracture: a 10-year Sientra study using round, smooth, and textured implants for breast augmentation.","volume":"141","author":"Calobrace","year":"2018","journal-title":"Plast Reconstr Surg"},{"key":"R31-20251001","doi-asserted-by":"crossref","first-page":"1005","DOI":"10.1016\/j.amjsurg.2020.09.020","article-title":"Capsular contracture in the modern era: a multidisciplinary look at the incidence and risk factors after mastectomy and implant-based breast reconstruction.","volume":"221","author":"Hammond","year":"2021","journal-title":"Am J Surg"},{"key":"R32-20251001","doi-asserted-by":"crossref","first-page":"e31837","DOI":"10.1097\/MD.0000000000031837","article-title":"Risk factors for capsular contracture after breast reconstruction with tissue expanders and silicone implants in nonirradiated patients: a retrospective observational cohort study.","volume":"101","author":"Iwahira","year":"2022","journal-title":"Medicine (Baltim)"}],"container-title":["Plastic and Reconstructive Surgery - Global Open"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/GOX.0000000000007170","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,1]],"date-time":"2025-10-01T12:03:41Z","timestamp":1759320221000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/GOX.0000000000007170"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,10]]},"references-count":31,"journal-issue":{"issue":"10","published-online":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/gox.0000000000007170","relation":{},"ISSN":["2169-7574"],"issn-type":[{"value":"2169-7574","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,10]]}}}