{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,31]],"date-time":"2026-10-31T22:18:17Z","timestamp":1793485097168,"version":"4.5.0"},"reference-count":15,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Health Physics"],"published-print":{"date-parts":[[2019,5]]},"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:p>Traditionally, dose estimations have been performed predominantly using anthropomorphic phantoms in an upright posture. However, an exclusively upright posture could reduce accuracy when estimating organ absorbed and effective doses for exposures in realistic postures. In this work, effective dose coefficients were computed using International Commission on Radiological Protection Publication 103 recommendations for monoenergetic photon plane sources (0.05\u201320 MeV) directed upward from below the feet (caudal) and downward from above the head (cranial) for articulated adult male and female stylized phantoms. The Monte Carlo radiation transport code and the Phantom With Moving Arms and Legs were used to calculate organ absorbed dose and effective dose coefficients for upright and two bent (45\u00b0 and 90\u00b0) phantom postures. The resulting coefficients for the bent phantoms were compared to those for the upright phantoms to determine whether the upright phantoms provide a comparable and conservative estimate when conducting dose estimations\/reconstructions. For the caudal source, most organs received higher doses when in a bent posture. For the cranial source, the breast, brain, and eyes received lower doses in the bent compared to the upright posture, while all other organs received higher doses. The effective doses for the articulated phantoms were higher than for the upright posture for both irradiation geometries, which could have implications when using the traditional model to estimate or reconstruct radiation doses during actual exposures.<\/jats:p>","DOI":"10.1097\/hp.0000000000000985","type":"journal-article","created":{"date-parts":[[2019,1,17]],"date-time":"2019-01-17T04:12:12Z","timestamp":1547698332000},"page":"599-606","source":"Crossref","is-referenced-by-count":6,"title":["Comparison of Organ and Effective Photon Dose Coefficients for Reference Phantoms in Articulated and Upright Postures in Cranial and Caudal Irradiation Geometries"],"prefix":"10.1097","volume":"116","author":[{"given":"Kathryn","family":"Bales","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shaheen","family":"Dewji","sequence":"additional","affiliation":[{"name":"Department of Nuclear Engineering, Center for Nuclear Security Science and Policy Initiatives, Texas A&M University, College Station, TX; formerly at Oak Ridge National Laboratory, Center for Radiation Protection Knowledge."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"bib3-20230816","first-page":"75","article-title":"Conversion coefficients for proton beams using standing and sitting male hybrid computational phantom calculated in idealized irradiation geometries","volume":"175","year":"2016","journal-title":"Radiat Protect Dosim"},{"key":"bib4-20230816","doi-asserted-by":"crossref","first-page":"7957","DOI":"10.1088\/0031-9155\/59\/24\/7957","article-title":"Organ and effective dose conversion coefficients for a sitting female hybrid computational phantom exposed to monoenergetic protons in idealized irradiation geometries","volume":"59","year":"2014","journal-title":"Phys Med Biol"},{"issue":"1060","key":"bib5-20230816","doi-asserted-by":"crossref","first-page":"20151034","DOI":"10.1259\/bjr.20151034","article-title":"Radiation protection of the eye lens in medical workers\u2014basis and impact of the ICRP recommendations","volume":"89","year":"2016","journal-title":"Br J Radiol Protect"},{"key":"bib6-20230816","doi-asserted-by":"crossref","first-page":"367","DOI":"10.1093\/rpd\/ncv548","article-title":"Comparison of monoenergetic photon organ dose rate coefficients for stylized and voxel phantoms submerged in air","volume":"172","year":"2016","journal-title":"Radiat Protect Dosim"},{"key":"bib7-20230816","doi-asserted-by":"crossref","first-page":"158","DOI":"10.1016\/j.radphyschem.2012.12.028","article-title":"Comparison of conversion coefficients for equivalent dose in terms of air kerma using a sitting and standing female adult voxel simulators exposure to photons in antero-posterior irradiation geometry","volume":"95","year":"2014","journal-title":"Radiat Phys Chem"},{"key":"bib11-20230816","doi-asserted-by":"crossref","first-page":"277","DOI":"10.1007\/s00411-017-0698-1","article-title":"Comparison of organ doses for PIMAL stylized phantoms in upright and bent positions for standard irradiation geometries","volume":"56","year":"2017","journal-title":"Radiat Environ Biophys"},{"key":"bib12-20230816","doi-asserted-by":"crossref","first-page":"233","DOI":"10.1016\/j.radphyschem.2013.05.010","article-title":"Comparison of conversion coefficients for equivalent dose in terms of air kerma for photons using a male adult voxel simulator in sitting and standing posture with geometry of irradiation antero-posterior","volume":"95","year":"2014","journal-title":"Radiat Phys Chem"},{"key":"bib13-20230816","doi-asserted-by":"crossref","first-page":"50","DOI":"10.1016\/j.radphyschem.2015.12.018","article-title":"Fluence-to-dose conversion coefficients based on the posture modification of adult male (AM) and adult female (AF) reference phantoms of ICRP 110","volume":"121","year":"2016","journal-title":"Radiat Phys Chem"},{"key":"bib14-20230816","first-page":"37","article-title":"Effective dose conversion coefficients for health care provider exposed to pediatric and adult victims in radiological dispersal device incident","volume":"35","year":"2014","journal-title":"J Radiol Protect"},{"key":"bib15-20230816","doi-asserted-by":"crossref","first-page":"336","DOI":"10.1093\/rpd\/ncw354","article-title":"Comparison of monoenergetic photon organ dose rate coefficients for the female stylized and voxel phantoms submerged in air","volume":"175","year":"2017","journal-title":"Radiat Protect Dosim"},{"key":"bib20-20230816","first-page":"239","article-title":"Computational anthropomorphic phantoms for radiation protection dosimetry: evolution and prospects","volume":"38","year":"2006","journal-title":"Nucl Eng Technol"},{"key":"bib21-20230816","doi-asserted-by":"crossref","first-page":"392","DOI":"10.1093\/rpd\/nci087","article-title":"Application of a sitting MIRD phantom for effective dose calculations","volume":"116","year":"2005","journal-title":"Radiat Protect Dosim"},{"key":"bib23-20230816","first-page":"439","article-title":"Calculated organ equivalent doses for individuals in a sitting posture above a contaminated ground and a PET imaging room","volume":"148","year":"2011","journal-title":"Radiat Protect Dosim"},{"key":"bib24-20230816","doi-asserted-by":"crossref","first-page":"5277","DOI":"10.1088\/0031-9155\/59\/18\/5277","article-title":"Development of posture- specific computational phantoms using motion capture technology and application to radiation dose-reconstruction for the 1999 Tokai-Mura nuclear criticality accident","volume":"59","year":"2014","journal-title":"Phys Med Biol"},{"key":"bib25-20230816","first-page":"167","article-title":"Organ and effective dose coefficients for cranial and caudal irradiation geometries: photons","volume":"168","year":"2015","journal-title":"Radiat Protect Dosim"}],"container-title":["Health Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00004032-201905000-00004","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,16]],"date-time":"2023-08-16T21:13:07Z","timestamp":1692220387000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00004032-201905000-00004"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,5]]},"references-count":15,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2019]]}},"URL":"https:\/\/doi.org\/10.1097\/hp.0000000000000985","relation":{},"ISSN":["1538-5159","0017-9078"],"issn-type":[{"value":"1538-5159","type":"electronic"},{"value":"0017-9078","type":"print"}],"subject":[],"published":{"date-parts":[[2019,5]]}}}