{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,31]],"date-time":"2026-08-31T20:25:42Z","timestamp":1788207942897,"version":"build-2803163510"},"reference-count":13,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,10]]},"abstract":"<jats:sec>\n                    <jats:title\/>\n                    <jats:p>The female and male computational phantom with moving arms and legs (PIMAL) are useful models for the calculation of the effective doses to workers in radiological occupational settings. In this study, Monte Carlo N-Particle (MCNP) Version 6.2 is used with PIMAL phantoms to simulate exposure in nuclear and medical settings. The PIMAL phantoms, defined by mathematical representation of the human body, allow for detailed assessment of equivalent dose to organs. These values are converted to effective dose (E) using sex- and age-average tissue weighting factors from ICRP Publication 103. Initial simulations of monoenergetic photons, electrons, and neutrons in the anterior-posterior (AP) geometry show good agreement with comparable results in the literature, obtained using the ICRP adult reference voxel phantoms and PIMAL phantoms in the standard upright position. For nuclear power applications, effective dose rates (\n                                    \n                                       \n                                    \n                                 ) are estimated for workers contaminated by radionuclides and compared with personal dose equivalent rates at 0.07\u2009mm depth, \n                                    \n                                       \n                                    \n                                 (0.07). Additionally, effective dose rates from neutron and gamma fields are calculated for personnel inside a CANDU-600 (CANada Deuterium Uranium) nuclear reactor at full-power. In medical applications, effective dose rates to staff exposed to positron emitters, either from injected patients or activated cyclotron targets, are also assessed. Across all scenarios, effective dose derived from PIMAL phantoms are consistent with operational dose quantities when available, supporting their use in dose assessment and radiation protection planning.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/hp.0000000000002124","type":"journal-article","created":{"date-parts":[[2026,2,25]],"date-time":"2026-02-25T15:01:09Z","timestamp":1772031669000},"page":"377-390","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Organ and Effective Dose Assessments Using MCNP with Computational PIMAL Phantoms and Realistic Eye Model in Radiological Workplaces"],"prefix":"10.1097","volume":"131","author":[{"given":"Salah","family":"Djeffal","sequence":"first","affiliation":[{"name":"Canadian Nuclear Safety Commission, Ottawa, ON, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jacques","family":"Dubeau","sequence":"additional","affiliation":[{"name":"DETEC, Gatineau, QC, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jiansheng","family":"Sun","sequence":"additional","affiliation":[{"name":"Canadian Nuclear Laboratories, Chalk River, ON, Canada."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fawaz","family":"Ali","sequence":"additional","affiliation":[{"name":"Canadian Nuclear Laboratories, Chalk River, ON, Canada."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alireza","family":"Talebitaher","sequence":"additional","affiliation":[{"name":"Canadian Nuclear Laboratories, Chalk River, ON, Canada."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,2,25]]},"reference":[{"key":"R2-20260831","doi-asserted-by":"crossref","first-page":"375","DOI":"10.1007\/s00411-018-0751-8","article-title":"Comparison of neutron organ and effective dose coefficients for PIMAL stylized phantom in bent postures in standard irradiation geometries.","volume":"57","author":"Bales","year":"2018","journal-title":"Radiat Environ Biophys"},{"key":"R3-20260831","doi-asserted-by":"crossref","first-page":"4069","DOI":"10.1088\/0031-9155\/54\/13\/008","article-title":"Dose conversion coefficients for electron exposure of the human eye lens.","volume":"54","author":"Behrens","year":"2009","journal-title":"Phys Med Biol"},{"key":"R4-20260831","first-page":"378","article-title":"Calculation of fluence-to-effective dose conversion coefficients for the operational quantity proposed by ICRU RC26.","volume":"175","author":"Endo","year":"2017","journal-title":"Radiat Prot Dosim"},{"key":"R6-20260831","doi-asserted-by":"crossref","first-page":"277","DOI":"10.1007\/s00411-017-0698-1","article-title":"Comparison of photon organ and effective dose coefficients for PIMAL stylized phantom in bent positions in standard irradiation geometries.","volume":"56","author":"Dewji","year":"2017","journal-title":"Radiat Environ Biophys"},{"key":"R7-20260831","first-page":"371","article-title":"Multiple methods for assessing the dose to skin exposed to radioactive contamination.","volume":"174","author":"Dubeau","year":"2017","journal-title":"Radiat Protect Dosim"},{"key":"R8-20260831","doi-asserted-by":"crossref","first-page":"660","DOI":"10.1093\/rpd\/ncad125","article-title":"A computer program for the determination of absolute activities in contaminations and skin doses.","volume":"199","author":"Dubeau","year":"2023","journal-title":"Radiat Prot Dosim"},{"key":"R10-20260831","doi-asserted-by":"crossref","first-page":"337","DOI":"10.1097\/01.HP.0000192318.13190.c4","article-title":"Revisions of the ORNL series of adult and pediatric computational phantom for use in the MIRD schema.","volume":"90","author":"Han","year":"2006","journal-title":"Health Phys"},{"key":"R17-20260831","first-page":"1","article-title":"ICRU Report 95, Operational quantities for external radiation exposure.","volume":"20","year":"2020","journal-title":"J ICRU"},{"key":"R18-20260831","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1097\/01.HP.0000176672.86806.89","article-title":"The sliced BOMAB phantom: a new variant for intercomparison.","volume":"90","author":"Kramer","year":"2006","journal-title":"Health Phys"},{"key":"R19-20260831","doi-asserted-by":"crossref","first-page":"012021","DOI":"10.1088\/1742-6596\/1662\/1\/012021","article-title":"Modelling ICRP110 adult reference voxel phantoms for dosimetric applications: development of a new Geant4 advanced example.","volume":"1662","author":"Large","year":"2020","journal-title":"J Phys Conf Ser"},{"key":"R21-20260831","first-page":"279","article-title":"Multisphere spectrometry and analysis of TEPC and REM meter results around a heavy water moderated reactor.","volume":"59","author":"Nunes","year":"1995","journal-title":"Radiat Protect Dosim"},{"key":"R22-20260831","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1097\/00004032-199608000-00017","article-title":"Neutron fields inside containment of a CANDU 600-PHWR power plant.","volume":"71","author":"Nunes","year":"1996","journal-title":"Health Phys"},{"key":"R25-20260831","doi-asserted-by":"crossref","first-page":"212","DOI":"10.1016\/S0168-9002(01)01379-1","article-title":"Bonner sphere spectrometers \u2014 a critical review.","volume":"476","author":"Thomas","year":"2002","journal-title":"Nuclear Inst Meth in Phys Res A"}],"container-title":["Health Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1097\/HP.0000000000002124","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,31]],"date-time":"2026-08-31T20:00:30Z","timestamp":1788206430000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1097\/HP.0000000000002124"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2,25]]},"references-count":13,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/hp.0000000000002124","relation":{},"ISSN":["0017-9078","1538-5159"],"issn-type":[{"value":"0017-9078","type":"print"},{"value":"1538-5159","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,2,25]]}}}