{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T21:56:04Z","timestamp":1790718964804,"version":"4.1.0"},"reference-count":26,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","license":[{"start":{"date-parts":[[2026,3,6]],"date-time":"2026-03-06T00:00:00Z","timestamp":1772755200000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,11]]},"abstract":"<jats:sec>\n                    <jats:title\/>\n                    <jats:p>\n                      As uranium is a health hazard for nuclear fuel workers, correct dose assessments are necessary to ensure worker safety. Absorption parameters of uranium aerosols are important parameters for the dose assessments. In this study, size-fractionated uranium aerosols of uranium hexafluoride (UF\n                      <jats:sub>6<\/jats:sub>\n                      ), ammonium uranyl carbonate (AUC), uranium dioxide (UO\n                      <jats:sub>2<\/jats:sub>\n                      ), and uranium octoxide (U\n                      <jats:sub>3<\/jats:sub>\n                      O\n                      <jats:sub>8<\/jats:sub>\n                      ) collected from four workshops at a nuclear fuel fabrication plant were used in two separate in vitro dissolution models, one with simulated lung-lining fluid (Gamble\u2019s fluid) and one with simulated phagolysosomal fluid (PSF). The dissolution characteristics in the different simulated lung environments were assessed. Lung absorption parameters: the rapid fraction (f\n                      <jats:sub>r<\/jats:sub>\n                      ), rapid rate (s\n                      <jats:sub>r<\/jats:sub>\n                      , d\n                      <jats:sup>-1<\/jats:sup>\n                      ), and slow rate (s\n                      <jats:sub>s<\/jats:sub>\n                      , d\n                      <jats:sup>-1<\/jats:sup>\n                      ) were derived, and the dosimetric impact was evaluated. The conversion workshop has a known presence of uranium aerosols of both soluble (UF\n                      <jats:sub>6<\/jats:sub>\n                      , AUC) and relatively insoluble (UO\n                      <jats:sub>2<\/jats:sub>\n                      ) compounds. Absorption parameters derived for dissolution in Gamble\u2019s fluid in comparison to dissolution in PSF showed a mixed pattern with impactor stages. Absorption parameters\n                      <jats:italic toggle=\"yes\">f<\/jats:italic>\n                      <jats:sub>r<\/jats:sub>\n                      ,\n                      <jats:italic toggle=\"yes\">s<\/jats:italic>\n                      <jats:sub>r<\/jats:sub>\n                      , and\n                      <jats:italic toggle=\"yes\">s<\/jats:italic>\n                      <jats:sub>s<\/jats:sub>\n                      were generally slightly lower in PSF. However, a higher slow rate in comparison to Gamble\u2019s fluid was derived in PSF for some impactor cut-points, indicative of the different solubilities of the mixed aerosols. The\n                      <jats:italic toggle=\"yes\">f<\/jats:italic>\n                      <jats:sub>r,<\/jats:sub>\n                      <jats:italic toggle=\"yes\">s<\/jats:italic>\n                      <jats:sub>r<\/jats:sub>\n                      , and\n                      <jats:italic toggle=\"yes\">s<\/jats:italic>\n                      <jats:sub>s<\/jats:sub>\n                      derived in PSF ranged between 0.1-0.3, 4-16 d\n                      <jats:sup>-1<\/jats:sup>\n                      , and 0.004-0.015 d\n                      <jats:sup>-1<\/jats:sup>\n                      , respectively. At the powder preparations and pelletizing workshops, less soluble uranium aerosols UO\n                      <jats:sub>2<\/jats:sub>\n                      and U\n                      <jats:sub>3<\/jats:sub>\n                      O\n                      <jats:sub>8<\/jats:sub>\n                      , are present. The absorption parameters derived for the pelletizing workshop from PSF were\n                      <jats:italic toggle=\"yes\">f<\/jats:italic>\n                      <jats:sub>r<\/jats:sub>\n                      : 0.02-0.025,\n                      <jats:italic toggle=\"yes\">s<\/jats:italic>\n                      <jats:sub>r<\/jats:sub>\n                      :4-6 d\n                      <jats:sup>-1<\/jats:sup>\n                      , and\n                      <jats:italic toggle=\"yes\">s<\/jats:italic>\n                      <jats:sub>s<\/jats:sub>\n                      : 0.0007-0.001 d\n                      <jats:sup>-1<\/jats:sup>\n                      . For the powder preparations workshops, the\n                      <jats:italic toggle=\"yes\">f<\/jats:italic>\n                      <jats:sub>r<\/jats:sub>\n                      ranged between 0.01-0.045,\n                      <jats:italic toggle=\"yes\">s<\/jats:italic>\n                      <jats:sub>r<\/jats:sub>\n                      ranged between 4-32 d\n                      <jats:sup>-1<\/jats:sup>\n                      , and\n                      <jats:italic toggle=\"yes\">s<\/jats:italic>\n                      <jats:sub>s<\/jats:sub>\n                      ranged between 0.002-0.004 d\n                      <jats:sup>-1<\/jats:sup>\n                      . The slow rates derived in PSF were several times higher than for Gamble\u2019s fluid, which resulted in\n                      <jats:italic toggle=\"yes\">s<\/jats:italic>\n                      <jats:sub>s<\/jats:sub>\n                      : 0.00009-0.0004 d\n                      <jats:sup>-1<\/jats:sup>\n                      and\n                      <jats:italic toggle=\"yes\">s<\/jats:italic>\n                      <jats:sub>s<\/jats:sub>\n                      : 0.0001-0.001 d\n                      <jats:sup>-1<\/jats:sup>\n                      for powder preparations and pelletizing workshops, respectively. The slow rate derived from dissolution in PSF showed good agreement with available in vivo data from studies performed at the pelletizing workshop. For the BA pelletizing workshop with UO\n                      <jats:sub>2<\/jats:sub>\n                      and U\n                      <jats:sub>3<\/jats:sub>\n                      O\n                      <jats:sub>8<\/jats:sub>\n                      aerosols that are blended with Gd\n                      <jats:sub>2<\/jats:sub>\n                      O\n                      <jats:sub>3<\/jats:sub>\n                      ,\n                      <jats:italic toggle=\"yes\">f<\/jats:italic>\n                      <jats:sub>r<\/jats:sub>\n                      ,\n                      <jats:italic toggle=\"yes\">s<\/jats:italic>\n                      <jats:sub>r<\/jats:sub>\n                      , and\n                      <jats:italic toggle=\"yes\">s<\/jats:italic>\n                      <jats:sub>s<\/jats:sub>\n                      ranged between, 0.05-0.1, 1-7 d\n                      <jats:sup>-1<\/jats:sup>\n                      and 0.002-0.005 d\n                      <jats:sup>-1<\/jats:sup>\n                      , respectively. No substantial differences in derived parameters for dissolution in PSF or Gamble\u2019s fluid were visible. The difference between dissolution patterns in the two fluids between aerosols from the BA pelletizing and from the other two workshops are believed to be related to differences in the specific surface area (SSA), differences in the mixture of uranium compounds, and the blending with Gd\n                      <jats:sub>2<\/jats:sub>\n                      O\n                      <jats:sub>3<\/jats:sub>\n                      . No significant correlation between absorption parameters and impactor stages was found in any of the solutions for the four workshops, with the exception of s\n                      <jats:sub>s<\/jats:sub>\n                      for powder preparation workshop in PSF (R\n                      <jats:sup>2<\/jats:sup>\n                      =0.76, p=0.03). The general conclusions, when evaluating absorption parameters derived for each workshop in PSF and in Gamble\u2019s fluid, were that the parameter most impacted by the type of lung fluid was the slow rate\n                      <jats:italic toggle=\"yes\">s<\/jats:italic>\n                      <jats:sub>s<\/jats:sub>\n                      and that the effect was most significant for more insoluble uranium. The findings in this study demonstrate that in vitro dissolution in simulated phagolysomal fluid give more realistic estimates of absorption parameters for relatively insoluble material, such as UO\n                      <jats:sub>2<\/jats:sub>\n                      and U\n                      <jats:sub>3<\/jats:sub>\n                      O\n                      <jats:sub>8<\/jats:sub>\n                      , that are more in line with in vivo data than in vitro dissolution in simulated lung lining fluid.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/hp.0000000000002137","type":"journal-article","created":{"date-parts":[[2026,3,6]],"date-time":"2026-03-06T15:01:05Z","timestamp":1772809265000},"page":"446-460","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Dissolution Behavior of Uranium Aerosols in Simulated Lung Fluids: Effects of Particle Size"],"prefix":"10.1097","volume":"131","author":[{"given":"Ibtisam","family":"Yusuf","sequence":"first","affiliation":[{"name":"Department of Medical Radiation Physics, and Department of Health, Medicine and Caring Sciences, Link\u00f6ping University, Link\u00f6ping, Sweden"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Edvin","family":"Hansson","sequence":"additional","affiliation":[{"name":"Department of Health, Medicine and Caring Sciences, Link\u00f6ping University, Link\u00f6ping, Sweden"},{"name":"Formerly at Westinghouse Electric Sweden AB, Br\u00e4nslegatan 1, 72136 V\u00e4ster\u00e5s, Sweden"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mats","family":"Eriksson","sequence":"additional","affiliation":[{"name":"Department of Health, Medicine and Caring Sciences, Link\u00f6ping University, Link\u00f6ping, Sweden"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M\u00e5rten","family":"Dario","sequence":"additional","affiliation":[{"name":"Department of Thematic Studies, Tema Environmental Change. Link\u00f6ping University, Link\u00f6ping, Sweden."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"H\u00e5kan B.L.","family":"Pettersson","sequence":"additional","affiliation":[{"name":"Department of Medical Radiation Physics, and Department of Health, Medicine and Caring Sciences, Link\u00f6ping University, Link\u00f6ping, Sweden"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,3,6]]},"reference":[{"key":"R1-20260929","doi-asserted-by":"crossref","first-page":"638","DOI":"10.1097\/00004032-199912000-00007","article-title":"Review and critical analysis of available in vitro dissolution tests.","volume":"77","author":"Ansoborlo","year":"1999","journal-title":"Health Phys"},{"key":"R2-20260929","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1016\/j.jnucmat.2016.04.025","article-title":"The effect of fuel chemistry on UO2 dissolution.","volume":"476","author":"Casella","year":"2016","journal-title":"J Nucl Mater"},{"key":"R3-20260929","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1093\/oxfordjournals.rpd.a032434","article-title":"Effect of U3O8 specific surface area on in vitro dissolution, biokinetics, and dose coefficients.","volume":"79","author":"Chazel","year":"1998","journal-title":"Radiat Prot Dosim"},{"key":"R4-20260929","doi-asserted-by":"crossref","first-page":"223","DOI":"10.1093\/oxfordjournals.rpd.a033039","article-title":"Variation of solubility, biokinetics and dose coefficient of industrial uranium oxides according to the specific surface area.","volume":"88","author":"Chazel","year":"2000","journal-title":"Radiat Prot Dosim"},{"key":"R5-20260929","doi-asserted-by":"crossref","first-page":"975","DOI":"10.3109\/09553002.2014.886796","article-title":"Physico-chemical characteristics of uranium compounds: a review.","volume":"90","author":"Davesne","year":"2014","journal-title":"Int J Radiat Biol"},{"key":"R7-20260929","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1080\/00401706.1969.10490657","article-title":"Procedures for detecting outlying observations in samples.","volume":"11","author":"Grubbs","year":"1969","journal-title":"Technometrics"},{"key":"R8-20260929","doi-asserted-by":"crossref","first-page":"66","DOI":"10.1016\/S0925-8388(98)00026-7","article-title":"Issues and research on the biochemistry of inhaled actinides.","volume":"271-273","author":"Guilmette","year":"1998","journal-title":"J Alloys Compd"},{"key":"R10-20260929","doi-asserted-by":"crossref","first-page":"233","DOI":"10.1016\/S0003-4878(98)00026-X","article-title":"Measurement of in-vitro fibre dissolution rate at acidic pH.","volume":"42","author":"Guldberg","year":"1998","journal-title":"Ann Occup Hyg"},{"key":"R11-20260929","doi-asserted-by":"crossref","first-page":"266","DOI":"10.1016\/0167-5087(84)90659-8","article-title":"A method for the electrodeposition of actinides.","volume":"223","author":"Hallstadius","year":"1984","journal-title":"Nucl Instrum Methods Phys Res"},{"key":"R12-20260929","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1097\/HP.0000000000001564","article-title":"Particle size-dependent dissolution of uranium aerosols in simulated lung fluid: a case study in a nuclear fuel fabrication plant.","volume":"123","author":"Hansson","year":"2022","journal-title":"Health Phys"},{"key":"R13-20260929","doi-asserted-by":"crossref","first-page":"327","DOI":"10.1097\/HP.0000000000001254","article-title":"Uranium aerosol activity size distributions at a nuclear fuel fabrication plant.","volume":"119","author":"Hansson","year":"2020","journal-title":"Health Phys"},{"key":"R14-20260929","doi-asserted-by":"crossref","first-page":"130","DOI":"10.1016\/j.sab.2017.03.002","article-title":"Uranium aerosols at a nuclear fuel fabrication plant: characterization using scanning electron microscopy and energy dispersive x-ray spectroscopy.","volume":"131","author":"Hansson","year":"2017","journal-title":"Spectrochim Acta Part B"},{"key":"R15-20260929","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1093\/rpd\/53.1-4.157","article-title":"Solubility and transferability of several industrial forms of uranium oxides.","volume":"53","author":"Henge-Napoli","year":"1994","journal-title":"Radiat Prot Dosim"},{"key":"R16-20260929","first-page":"413","article-title":"Role of alveolar macrophages in the dissolution of two different industrial uranium oxides.","volume":"42","author":"Heng\u00e9-Napoli","year":"1996","journal-title":"Cell Mol Biol Noisy--Gd Fr"},{"key":"R17-20260929","doi-asserted-by":"crossref","first-page":"62","DOI":"10.1021\/acs.estlett.8b00557","article-title":"Mineralogy controlled dissolution of uranium from airborne dust in simulated lung fluids (SLFs) and possible health implications.","volume":"6","author":"Hettiarachchi","year":"2019","journal-title":"Environ Sci Technol Lett"},{"key":"R24-20260929","doi-asserted-by":"crossref","first-page":"217","DOI":"10.1080\/10408444.2021.1903386","article-title":"Simulated biological fluids \u2014 a systematic review of their biological relevance and use in relation to inhalation toxicology of particles and fibres.","volume":"51","author":"Innes","year":"2021","journal-title":"Crit Rev Toxicol"},{"key":"R25-20260929","first-page":"2008","article-title":"Evaluation of measurement data \u2014 supplement 1 to the \u201cGuide to the expression of uncertainty in measurement\u201d \u2014 propagation of distributions using a Monte Carlo method.","volume":"101","year":"2008","journal-title":"JCGM"},{"key":"R27-20260929","doi-asserted-by":"crossref","first-page":"265","DOI":"10.1515\/pac-2015-0305","article-title":"Atomic weights of the elements 2013 (IUPAC Technical Report).","volume":"88","author":"Meija","year":"2016","journal-title":"Pure Appl Chem"},{"key":"R28-20260929","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1289\/ehp.9297127","article-title":"In vitro dissolution of uranium oxide by baboon alveolar macrophages.","volume":"97","author":"Poncy","year":"1992","journal-title":"Environ Health Perspect"},{"key":"R29-20260929","doi-asserted-by":"crossref","first-page":"153008","DOI":"10.1016\/j.jnucmat.2021.153008","article-title":"Effect of added gadolinium oxide on the thermal air oxidation of uranium dioxide.","volume":"552","author":"Scheele","year":"2021","journal-title":"J Nucl Mater"},{"key":"R30-20260929","doi-asserted-by":"crossref","first-page":"527","DOI":"10.1016\/j.jenvrad.2007.08.009","article-title":"In vitro dissolution studies of uranium bearing material in simulated lung fluid.","volume":"99","author":"Sdraulig","year":"2008","journal-title":"J Environ Radioact"},{"key":"R31-20260929","doi-asserted-by":"crossref","first-page":"123","DOI":"10.1016\/j.tiv.2004.08.001","article-title":"Characterization of phagolysosomal simulant fluid for study of beryllium aerosol particle dissolution.","volume":"19","author":"Stefaniak","year":"2005","journal-title":"Toxicol In Vitro"},{"key":"R32-20260929","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1080\/08958378.2017.1333548","article-title":"Application of the ICRP respiratory tract model to estimate pulmonary retention of industrially sampled indium-containing dusts.","volume":"29","author":"Stefaniak","year":"2017","journal-title":"Inhal Toxicol"},{"key":"R33-20260929","doi-asserted-by":"crossref","first-page":"1468","DOI":"10.1021\/tx049878k","article-title":"Uranium (VI) solubility and speciation in simulated elemental human biological fluids.","volume":"17","author":"Sutton","year":"2004","journal-title":"Chem Res Toxicol"},{"key":"R35-20260929","doi-asserted-by":"crossref","first-page":"520","DOI":"10.1097\/HP.0000000000001861","article-title":"Uranium body clearance kinetics \u2014 a long-term follow-up study of retired nuclear fuel workers.","volume":"127","author":"Yusuf","year":"2024","journal-title":"Health Phys"},{"key":"R36-20260929","doi-asserted-by":"crossref","first-page":"285","DOI":"10.1097\/HP.0000000000001668","article-title":"Particle size dependent dissolution of uranium aerosols in simulated gastrointestinal fluids.","volume":"124","author":"Yusuf","year":"2023","journal-title":"Health Phys"}],"container-title":["Health Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1097\/HP.0000000000002137","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T21:00:26Z","timestamp":1790715626000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1097\/HP.0000000000002137"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3,6]]},"references-count":26,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/hp.0000000000002137","relation":{},"ISSN":["0017-9078","1538-5159"],"issn-type":[{"value":"0017-9078","type":"print"},{"value":"1538-5159","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,3,6]]}}}