{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,12]],"date-time":"2026-06-12T14:56:56Z","timestamp":1781276216594,"version":"3.54.1"},"reference-count":23,"publisher":"Ovid Technologies (Wolters Kluwer Health)","funder":[{"name":"General Hospital of Western Theater Command","award":["2021-XZYG-C04"],"award-info":[{"award-number":["2021-XZYG-C04"]}]}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:p>\n                    Reducing radiation exposure in pediatric imaging is a key focus globally, and it is necessary to establish diagnostic reference levels (DRLs) for contrast-enhanced computed tomography (CT) in children. This study assesses typical radiation dose values from contrast-enhanced CT examinations of children to provide a reference for internal quality control. A retrospective analysis was conducted on contrast-enhanced CT data from 330 pediatric patients at our hospital between January 2020 and December 2024. Patients were categorized into four age groups: 0\u20134 y, &gt;4\u201310 y, &gt;10\u201314 y, and &gt;14\u201318 y. Basic patient information, CT scan parameters, total computed tomography volume dose index (CTDI\n                    <jats:sub>vol<\/jats:sub>\n                    ), and dose-length product (DLP) were collected. Differences in total CTDI\n                    <jats:sub>vol<\/jats:sub>\n                    , DLP, and effective dose among different age groups were analyzed and compared with DRL values from domestic and international studies. The effective dose values for head CTA, neck, chest, coronary artery, liver, kidney, and abdomen were 54.48, 21.46, 7.76, 8.58, 14,74, 7.27, and 17.96 mSv, respectively. No significant differences across different age groups were observed in total CTDI\n                    <jats:sub>vol<\/jats:sub>\n                    and DLP for head angiography, neck, chest, and coronary artery scans (CTDI\n                    <jats:sub>vol<\/jats:sub>\n                    : \u03c7\n                    <jats:sup>2<\/jats:sup>\n                    =4.31, 4.77, 0.48, 7.50; DLP: \u03c7\n                    <jats:sup>2<\/jats:sup>\n                    =4.85, 2.03, 2.38, 4.17 P&gt;0.05). However, significant differences were found in total CTDI\n                    <jats:sub>vol<\/jats:sub>\n                    and DLP for liver, kidney and abdominal scans among different age groups (CTDI\n                    <jats:sub>vol<\/jats:sub>\n                    : \u03c7\n                    <jats:sup>2<\/jats:sup>\n                    =2.19, 8.86, 11.26; DLP: \u03c7\n                    <jats:sup>2<\/jats:sup>\n                    =3.76, 7.71, 10.07; P&lt;0.05). This study revealed the radiation dose for some regions does not show significant differences among different ages in CT enhanced scans, and the CTDI\n                    <jats:sub>vol<\/jats:sub>\n                    values for some ages exceeded international DRL standards, indicating a need for optimization of contrast-enhanced CT scanning protocols in children in our hospital.\n                  <\/jats:p>","DOI":"10.1097\/hp.0000000000002147","type":"journal-article","created":{"date-parts":[[2026,6,12]],"date-time":"2026-06-12T14:02:32Z","timestamp":1781272952000},"update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Analysis of Contrast-enhanced CT Radiation Dose in Children"],"prefix":"10.1097","author":[{"given":"Fang","family":"Wang","sequence":"first","affiliation":[{"name":"Department of Radiology, The General Hospital of Western Theater Command, Chengdu 610083, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jinping","family":"Sheng","sequence":"additional","affiliation":[{"name":"Department of Radiology, The General Hospital of Western Theater Command, Chengdu 610083, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Guoyong","family":"Zhang","sequence":"additional","affiliation":[{"name":"Department of Radiology, The General Hospital of Western Theater Command, Chengdu 610083, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Liwen","family":"Ma","sequence":"additional","affiliation":[{"name":"Department of Radiology, The General Hospital of Western Theater Command, Chengdu 610083, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhiwei","family":"Zuo","sequence":"additional","affiliation":[{"name":"Department of Radiology, The General Hospital of Western Theater Command, Chengdu 610083, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rui","family":"Jiang","sequence":"additional","affiliation":[{"name":"Department of Radiology, The General Hospital of Western Theater Command, Chengdu 610083, China."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,6,12]]},"reference":[{"key":"R1-20260612","doi-asserted-by":"crossref","first-page":"423","DOI":"10.1093\/rpd\/ncac069","article-title":"2021 National diagnostic reference levels for paediatric computed tomography in egypt.","volume":"198","author":"Abdou","year":"2022","journal-title":"Radiat Prot Dosim"},{"key":"R2-20260612","doi-asserted-by":"crossref","first-page":"190","DOI":"10.1016\/j.bulcan.2015.11.003","article-title":"[Exposure to CT scans in childhood and long-term cancer risk: A review of epidemiological studies].","volume":"103","author":"Baysson","year":"2016","journal-title":"Bull Cancer"},{"key":"R3-20260612","doi-asserted-by":"crossref","first-page":"3111","DOI":"10.1038\/s41591-023-02620-0","article-title":"Risk of hematological malignancies from CT radiation exposure in children, adolescents and young adults.","volume":"29","author":"Bosch de Basea","year":"2023","journal-title":"Nat Med"},{"key":"R4-20260612","doi-asserted-by":"crossref","first-page":"2277","DOI":"10.1056\/NEJMra072149","article-title":"Computed tomography--an increasing source of radiation exposure.","volume":"357","author":"Brenner","year":"2007","journal-title":"N Engl J Med"},{"key":"R5-20260612","first-page":"584","article-title":"Excess lifetime cancer mortality risk attributable to radiation exposure from computed tomography examinations in children.","volume":"9","author":"Chodick","year":"2007","journal-title":"Israel Med Assoc J"},{"key":"R6-20260612","doi-asserted-by":"crossref","first-page":"158","DOI":"10.1148\/radiol.10100047","article-title":"Multisection CT protocols: sex- and age-specific conversion factors used to determine effective dose from dose-length product.","volume":"257","author":"Deak","year":"2010","journal-title":"Radiology"},{"key":"R22-20260612","year":"2018","journal-title":"European Guidelines on Diagnostic Reference Levels for Paediatric Imaging, Radiation Protection 185"},{"key":"R7-20260612","doi-asserted-by":"crossref","first-page":"702","DOI":"10.1007\/s00247-019-04346-z","article-title":"European Society of Paediatric Radiology Computed Tomography and Dose Task Force: European guidelines on diagnostic reference levels for paediatric imaging.","volume":"49","author":"Granata","year":"2019","journal-title":"Pediatr Radiol"},{"key":"R8-20260612","doi-asserted-by":"crossref","first-page":"214","DOI":"10.1093\/rpd\/ncab093","article-title":"Estimation of diagnostic reference levels and achievable doses for pediatric patients in common computed tomography examinations: a multi-center study.","volume":"194","author":"Hamed","year":"2021","journal-title":"Radiat Protect Dosim"},{"key":"R9-20260612","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1016\/S1470-2045(22)00655-6","article-title":"Brain cancer after radiation exposure from CT examinations of children and young adults: results from the EPI-CT cohort study.","volume":"24","author":"Hauptmann","year":"2023","journal-title":"Lancet Oncol"},{"key":"R10-20260612","doi-asserted-by":"crossref","first-page":"615","DOI":"10.1007\/s13246-016-0431-4","article-title":"Derivation of Australian diagnostic reference levels for paediatric multi detector computed tomography.","volume":"39","author":"Hayton","year":"2016","journal-title":"Aust Phys Eng Sci Med"},{"key":"R11-20260612","doi-asserted-by":"crossref","first-page":"164","DOI":"10.1148\/radiol.2021211241","article-title":"U.S. diagnostic reference levels and achievable doses for 10 pediatric CT examinations.","volume":"302","author":"Kanal","year":"2022","journal-title":"Radiology"},{"key":"R12-20260612","first-page":"f2360","article-title":"Cancer risk in 680,000 people exposed to computed tomography scans in childhood or adolescence: data linkage study of 11 million Australians.","volume":"346","author":"Mathews","year":"2013","journal-title":"BMJ (Clinical research ed.)"},{"key":"R13-20260612","doi-asserted-by":"crossref","first-page":"20180290","DOI":"10.1259\/bjr.20180290","article-title":"Diagnostic reference levels and achievable doses for common computed tomography examinations: Results from the Japanese nationwide dose survey.","volume":"92","author":"Matsunaga","year":"2019","journal-title":"Br J Radiol"},{"key":"R14-20260612","doi-asserted-by":"crossref","first-page":"700","DOI":"10.1001\/jamapediatrics.2013.311","article-title":"The use of computed tomography in pediatrics and the associated radiation exposure and estimated cancer risk.","volume":"167","author":"Miglioretti","year":"2013","journal-title":"JAMA Pediatr"},{"key":"R15-20260612","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1016\/j.ejmp.2022.09.004","article-title":"Patient size as a parameter for determining diagnostic reference levels for paediatric computed tomography (CT) procedures.","volume":"102","author":"Satharasinghe","year":"2022","journal-title":"Phys Medica"},{"key":"R16-20260612","doi-asserted-by":"crossref","first-page":"101732","DOI":"10.1016\/j.canep.2020.101732","article-title":"CT scans in childhood predict subsequent brain cancer: finite mixture modelling can help separate reverse causation scans from those that may be causal.","volume":"67","author":"Smoll","year":"2020","journal-title":"Cancer Epidemiol"},{"key":"R23-20260612","first-page":"1135","article-title":"Investigation of radiation dose and diagnostic reference levels in CT scanning for children.","volume":"56","author":"Sun","year":"2022","journal-title":"Chin J Radiol"},{"key":"R17-20260612","doi-asserted-by":"crossref","first-page":"108","DOI":"10.1186\/s12880-021-00637-w","article-title":"Application of a deep learning image reconstruction (DLIR) algorithm in head CT imaging for children to improve image quality and lesion detection.","volume":"21","author":"Sun","year":"2021","journal-title":"BMC Med Imaging"},{"key":"R18-20260612","doi-asserted-by":"crossref","first-page":"280","DOI":"10.1007\/s00247-015-3474-x","article-title":"Nationwide survey of radiation exposure during pediatric computed tomography examinations and proposal of age-based diagnostic reference levels for Japan.","volume":"46","author":"Takei","year":"2016","journal-title":"Pediatr Radiol"},{"key":"R19-20260612","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1007\/s11547-016-0709-3","article-title":"Radiation exposure in diagnostic imaging: wisdom and prudence, but still a lot to understand.","volume":"122","author":"Tom\u00e0","year":"2017","journal-title":"La Radiologia Medica"},{"key":"R20-20260612","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1093\/rpd\/ncv113","article-title":"Patient grouping for dose surveys and establishment of diagnostic reference levels in paediatric computed tomography.","volume":"165","author":"Vassileva","year":"2015","journal-title":"Radiat Prot Dosim"},{"key":"R21-20260612","doi-asserted-by":"crossref","first-page":"E575","DOI":"10.1503\/cmaj.221303","article-title":"Risks of leukemia, intracranial tumours and lymphomas in childhood and early adulthood after pediatric radiation exposure from computed tomography.","volume":"195","author":"Wang","year":"2023","journal-title":"CMAJ"}],"container-title":["Health Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/HP.0000000000002147","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,12]],"date-time":"2026-06-12T14:02:35Z","timestamp":1781272955000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/HP.0000000000002147"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,12]]},"references-count":23,"URL":"https:\/\/doi.org\/10.1097\/hp.0000000000002147","relation":{},"ISSN":["0017-9078","1538-5159"],"issn-type":[{"value":"0017-9078","type":"print"},{"value":"1538-5159","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,12]]}}}