{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,14]],"date-time":"2026-05-14T18:18:54Z","timestamp":1778782734060,"version":"3.51.4"},"reference-count":18,"publisher":"Ovid Technologies (Wolters Kluwer Health)","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:p>\n                    To ensure the accuracy of single-point sampling for airborne effluents in nuclear facilities, it is critical to clarify how stack and duct configurations regulate the flow field uniformity (velocity distribution) and aerosol distribution of the effluents. Taking the exhaust system of nuclear facilities as the research object, this study built a modular experimental platform covering seven duct configurations. Combined with experimental measurements and computational fluid dynamics (CFD) simulations, it systematically explored the impacts of duct configurations (including I, L, S, U types with smooth or right-angle transitions) and Reynolds numbers (Re = 5\u2009\u00d7\u200910\n                    <jats:sup>4<\/jats:sup>\n                    \u20131.5\u2009\u00d7\u200910\n                    <jats:sup>5<\/jats:sup>\n                    ) on the coefficient of variation (COV) of velocity distribution and that of polydisperse aerosol distribution (average particle size: 5.2 \u03bcm). The CFD model established achieved excellent validation accuracy: over 93% of velocity data points showed a deviation between simulated and experimental values within \u00b115%, and the ratio of simulated to experimental aerosol concentration values followed a log-normal distribution with a mean (\u03bc) of 1.13 and a standard deviation (\u03c3) of 0.26. For flow field uniformity: long straight ducts lacked sufficient turbulence, resulting in a velocity COV &gt;14% even at a length-to-hydraulic diameter ratio (L\/D) of 20; elbows effectively reduced the velocity COV, with right angle transition elbows having a stronger turbulence effect than smooth-transition ones (e.g., L2 circular ducts reached a velocity COV &lt;20% at L\/D = 8, while L1 ducts required an L\/D of 16 to achieve the same level); the S-type double-elbow ducts presented the highest flow field homogenization efficiency (S2 circular ducts achieved a velocity COV &lt;20% at L\/D = 7). For aerosol distribution: long straight ducts exhibited extremely poor aerosol mixing (COV &gt;140% at L\/D = 20); elbows promoted aerosol diffusion by enhancing vortex flow, with the right-angle transition S2 circular ducts performing the best (aerosol COV &lt;20% at L\/D = 4 and &lt;10% at L\/D = 20). When Re exceeded 10\n                    <jats:sup>4<\/jats:sup>\n                    , further increasing the Re did not significantly improve flow velocity uniformity or aerosol mixing. The CFD method and regulatory requirements revealed in this study can provide technical support for optimizing sampling cross-sections in existing nuclear facilities and designing duct configurations for proposed ones.\n                  <\/jats:p>","DOI":"10.1097\/hp.0000000000002152","type":"journal-article","created":{"date-parts":[[2026,5,14]],"date-time":"2026-05-14T18:00:55Z","timestamp":1778781655000},"update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Influence of Different Duct Configurations on Flow Field Uniformity and Aerosol Distribution of Airborne Effluents in Nuclear Facilities: Experimental and CFD Simulation Study"],"prefix":"10.1097","author":[{"given":"Jinge","family":"Zheng","sequence":"first","affiliation":[{"name":"China Institute of Atomic Energy, P.O. Box 275, Beijing, 102400, China"},{"name":"Nuclear and Radiation Safety Center, Haidian District, Beijing, 100082, China."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Haocheng","family":"Guo","sequence":"additional","affiliation":[{"name":"China Institute of Atomic Energy, P.O. Box 275, Beijing, 102400, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Weiya","family":"Cheng","sequence":"additional","affiliation":[{"name":"China Institute of Atomic Energy, P.O. Box 275, Beijing, 102400, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhiping","family":"Luo","sequence":"additional","affiliation":[{"name":"China Institute of Atomic Energy, P.O. Box 275, Beijing, 102400, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2026,5,14]]},"reference":[{"key":"R20-20260514","year":"1999"},{"key":"R21-20260514","year":"2011"},{"key":"R3-20260514","doi-asserted-by":"crossref","first-page":"82","DOI":"10.1097\/00004032-200301000-00007","article-title":"Gas mixing for achieving suitable conditions for single point aerosol sampling in a straight tube: experimental and numerical results.","volume":"84","author":"Anand","year":"2003","journal-title":"Health Phys"},{"key":"R4-20260514","doi-asserted-by":"crossref","first-page":"3212","DOI":"10.1080\/15567036.2024.2314163","article-title":"Identification of exhaust stack sampling location of a research reactor considering ANSI\/HPS N13.1-2011 mixing criteria using computational fluid dynamics.","volume":"46","author":"Ashraf","year":"2024","journal-title":"Energy Sources"},{"key":"R5-20260514","doi-asserted-by":"crossref","first-page":"406","DOI":"10.1097\/00004032-200404000-00010","article-title":"Evaluation of sampling locations for two radionuclide air-sampling systems based on the requirements of ANSI\/HPS N13.1-1999.","volume":"86","author":"Ballinger","year":"2004","journal-title":"Health Phys"},{"key":"R6-20260514","doi-asserted-by":"crossref","first-page":"103338","DOI":"10.1016\/j.pnucene.2020.103338","article-title":"Modeling filtered building effluent stack sampling points for qualification criteria.","volume":"124","author":"Barnett","year":"2020","journal-title":"Prog Nucl Energy"},{"key":"R7-20260514","doi-asserted-by":"crossref","first-page":"1235","DOI":"10.2298\/TSCI1504235D","article-title":"Flow and deposition characteristics of nanoparticles in a 90\u00b0 square bend.","volume":"19","author":"Dai","year":"2015","journal-title":"Ther Sci"},{"key":"R9-20260514","doi-asserted-by":"crossref","first-page":"908","DOI":"10.1007\/s10891-010-0413-4","article-title":"Deposition of aerosol particles in vertical channels from an isotropic turbulent flow.","volume":"83","author":"Kelbaliev","year":"2010","journal-title":"J Eng Phys Thermophys"},{"key":"R10-20260514","doi-asserted-by":"crossref","first-page":"173","DOI":"10.7733\/jnfcwt.2017.15.2.173","article-title":"An assessment of air sampling location for stack monitoring in nuclear facility.","volume":"15","author":"Lee","year":"2017","journal-title":"J Nucl Fuel Cycle Waste Technol"},{"key":"R11-20260514","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1016\/j.ijmultiphaseflow.2013.12.001","article-title":"Penetration efficiency and distribution of aerosol particles in turbulent duct flow undergoing coagulation and breakage.","volume":"61","author":"Lin","year":"2014","journal-title":"Int J Multiphase Flow"},{"key":"R12-20260514","doi-asserted-by":"crossref","first-page":"3016","DOI":"10.2514\/1.J053865","article-title":"Wall-distance-free version of Spalart\u2013Allmaras turbulence model.","volume":"53","author":"Rahman","year":"2015","journal-title":"AIAA J"},{"key":"R13-20260514","doi-asserted-by":"crossref","first-page":"1066","DOI":"10.4236\/jep.2025.1610057","article-title":"Computational fluid dynamics modeling to facilitate qualification of stack sampling probe location.","volume":"16","author":"Suffield","year":"2025","journal-title":"J Environ Protec"},{"key":"R14-20260514","doi-asserted-by":"crossref","first-page":"362","DOI":"10.1007\/s11783-011-0365-8","article-title":"Computational fluid dynamics simulation of aerosol transport and deposition.","volume":"5","author":"Tang","year":"2011","journal-title":"Front Environ Sci Eng China"},{"key":"R15-20260514","doi-asserted-by":"crossref","first-page":"120","DOI":"10.3390\/app7020120","article-title":"A review of experimental techniques for measuring micro- to nano-particle-laden gas flows.","volume":"7","author":"Tu","year":"2017","journal-title":"Appl Sci"},{"key":"R16-20260514","doi-asserted-by":"crossref","first-page":"1410","DOI":"10.2298\/TSCI1205410Y","article-title":"Experimental study on nanoparticle deposition in straight pipe flow.","volume":"16","author":"Yin","year":"2012","journal-title":"Ther Sci"},{"key":"R17-20260514","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1016\/S1001-6058(15)60460-7","article-title":"Penetration efficiency of nanoparticles in a bend of circular cross-section.","volume":"27","author":"Yin","year":"2015","journal-title":"J Hydrodynamics"},{"key":"R18-20260514","doi-asserted-by":"crossref","first-page":"1746","DOI":"10.4209\/aaqr.2018.02.0047","article-title":"Thermophoresis and Brownian motion effects on nanoparticle deposition inside a 90\u00b0 square bend tube.","volume":"18","author":"Yin","year":"2018","journal-title":"Aerosol Air Qual Res"},{"key":"R19-20260514","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1017\/S0022112099007284","article-title":"Aerosol particle transport and deposition in vertical and horizontal turbulent duct flows.","volume":"406","author":"Zhang","year":"2000","journal-title":"J Fluid Mechanics"}],"container-title":["Health Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/HP.0000000000002152","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,14]],"date-time":"2026-05-14T18:00:58Z","timestamp":1778781658000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/HP.0000000000002152"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5,14]]},"references-count":18,"URL":"https:\/\/doi.org\/10.1097\/hp.0000000000002152","relation":{},"ISSN":["0017-9078","1538-5159"],"issn-type":[{"value":"0017-9078","type":"print"},{"value":"1538-5159","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,5,14]]}}}