{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,9]],"date-time":"2026-11-09T17:27:44Z","timestamp":1794245264312,"version":"4.9.0"},"reference-count":12,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"6","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,12]]},"abstract":"<jats:sec>\n                    <jats:title\/>\n                    <jats:p>This study assessed organ and effective doses in routine diagnostic radiography by combining measured entrance surface air kerma (ESAK) values with Monte Carlo-derived conversion coefficients. A total of 50 adult patients who underwent chest, abdominal, skull, and pelvic x rays at the Federal Teaching Hospital Jos were included. ESAK values were measured using a calibrated solid-state detector, and corresponding organ and effective doses were calculated using conversion factors derived from PCXMC simulations and International Commission on Radiological Protection (ICRP) guidelines. Effective doses ranged from low values for chest PA projections to higher doses for pelvic examinations, all within internationally accepted diagnostic reference levels (DRLs). The findings emphasize that while doses remain within safe thresholds, ongoing optimization of exposure parameters and adherence to ALARA (as low as reasonably achievable) principles are necessary to balance diagnostic benefit with radiation detriment.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/hp.0000000000002178","type":"journal-article","created":{"date-parts":[[2026,6,9]],"date-time":"2026-06-09T15:26:07Z","timestamp":1781018767000},"page":"554-558","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Estimation of Organ and Effective Doses in Diagnostic Radiography Using ESAK Metrics and Monte Carlo Conversion Factors"],"prefix":"10.1097","volume":"131","author":[{"given":"Muhammad Nuruddeen","family":"Abdulkareem","sequence":"first","affiliation":[{"name":"Department of Physics, Federal University of Kashere, Gombe, Nigeria"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Muhammad Mudassir","family":"Usman","sequence":"additional","affiliation":[{"name":"Department of Physics, Federal University of Kashere, Gombe, Nigeria"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ibrahim","family":"Olanrewaju Abiodun","sequence":"additional","affiliation":[{"name":"Department of Physics, Federal University of Kashere, Gombe, Nigeria"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Abdullahi","family":"Muhammad","sequence":"additional","affiliation":[{"name":"Department of Physics, Federal University of Kashere, Gombe, Nigeria"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ahmad","family":"Alhassan","sequence":"additional","affiliation":[{"name":"Department of Physics, Federal University of Kashere, Gombe, Nigeria"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohammed Shettima","family":"Nur","sequence":"additional","affiliation":[{"name":"Department of Physics, Federal University of Kashere, Gombe, Nigeria"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrew","family":"Adamu","sequence":"additional","affiliation":[{"name":"Nigerian Army University, Biu."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Saldip","family":"Butfa Ponfa","sequence":"additional","affiliation":[{"name":"Department of Physics, Federal University of Kashere, Gombe, Nigeria"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,6,9]]},"reference":[{"key":"R1-20261109","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1007\/s00247-020-04803-0","article-title":"Early life ionizing radiation exposure and cancer risks: systematic review and meta-analysis.","volume":"51","author":"Abalo","year":"2021","journal-title":"Pediatr Radiol"},{"key":"R2-20261109","doi-asserted-by":"crossref","first-page":"253","DOI":"10.47011\/17.2.12","article-title":"Annual effective dose equivalent and excess lifetime cancer risk from measured indoor background ionizing radiation in Pharmacy, Radiotherapy\/Oncology and Radiology Departments of Federal Teaching Hospital, Gombe, Gombe State, Nigeria.","volume":"17","author":"Abdulkareem","year":"2024","journal-title":"Jordan J Phys"},{"key":"R3-20261109","doi-asserted-by":"crossref","first-page":"47","DOI":"10.53294\/ijfmsr.2024.6.1.0039","article-title":"Comprehensive risk management and safety strategies in radiation use in medical imaging.","volume":"6:","author":"Adelodun","year":"2024","journal-title":"Int J Front Med Surg Res"},{"key":"R4-20261109","doi-asserted-by":"crossref","first-page":"S522","DOI":"10.1088\/1361-6498\/ac1c95","article-title":"Radiation exposures in pregnancy, health effects and risks to the embryo\/foetus information to inform the medical management of the pregnant patient.","volume":"41","author":"Applegate","year":"2021","journal-title":"J Radiol Protect"},{"key":"R5-20261109","doi-asserted-by":"crossref","first-page":"410","DOI":"10.1088\/1361-6498\/abe548","article-title":"The use of dose quantities in radiological protection: ICRP publication 147.","volume":"41","author":"Harrison","year":"2021","journal-title":"J Radiol Protect"},{"key":"R6-20261109","doi-asserted-by":"crossref","first-page":"5164970","DOI":"10.1155\/2022\/5164970","article-title":"Modern diagnostic imaging technique applications and risk factors in the medical field: a review.","volume":"2022","author":"Hussain","year":"2022","journal-title":"Biomed Res Int"},{"key":"R16-20261109","article-title":"Dosimetry in diagnostic radiology: an International code of practice.","year":"2007"},{"issue":"(1)","key":"R17-20261109","article-title":"Diagnostic reference levels in medical imaging.","volume":"46","year":"2017"},{"key":"R10-20261109","first-page":"1","article-title":"Medical imaging: a critical review on x-ray imaging for the detection of infection.","volume":"4","author":"Irede","year":"2024","journal-title":"Biomed Mater Devices"},{"key":"R11-20261109","first-page":"031214","article-title":"Patient dose monitoring and the use of diagnostic reference levels for the optimization of protection in medical imaging: current status and challenges worldwide.","volume":"4","author":"Jarvinen","year":"2017","journal-title":"J Med Imaging (Bellingham)"},{"key":"R13-20261109","doi-asserted-by":"crossref","first-page":"39","DOI":"10.21608\/jsfw.2025.409882.1003","article-title":"The applications of x-ray technology in medical imaging: advances, challenges, and future perspectives (A review).","volume":"1","author":"Rayan","year":"2025","journal-title":"J Sustainable Food Water Energy Environ"},{"key":"R15-20261109","doi-asserted-by":"crossref","first-page":"2403","DOI":"10.1002\/mp.13471","article-title":"Construction of patient-specific computational models for organ dose estimation in radiological imaging.","volume":"46","author":"Xie","year":"2019","journal-title":"Med Phys"}],"container-title":["Health Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1097\/HP.0000000000002178","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,11,9]],"date-time":"2026-11-09T17:00:11Z","timestamp":1794243611000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1097\/HP.0000000000002178"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,9]]},"references-count":12,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/hp.0000000000002178","relation":{},"ISSN":["0017-9078","1538-5159"],"issn-type":[{"value":"0017-9078","type":"print"},{"value":"1538-5159","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,9]]},"assertion":[{"value":"2026-01-06","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-03-25","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}