{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,9,13]],"date-time":"2023-09-13T17:03:32Z","timestamp":1694624612508},"reference-count":21,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2020,6]]},"abstract":"<jats:sec>\n            <jats:title>Objective:<\/jats:title>\n            <jats:p>This study aimed to investigate the trends in the care of patients undergoing implantable cardioverter-defibrillator (ICD) implantation in our region and to analyze whether the quality of care is the same as the other centers or not?<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>Adult patients with an indication for ICD implants were enrolled in our registry and followed over a 19\u201343-month period.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>The ICD implantation rate was 100\/million per year. The mean age of patients treated with ICD was 62.36 (\u00b112.93) years old and the majority of patients were men (77.6%). Most patients had ischemic heart failure (65.2%). Nearly half of the patients had NYHA class III (53.8%) and the mean of ejection fraction was 26.7 (\u00b19.8%). ICDs were frequently implanted for primary prevention (71.9%). Single chamber ICDs (ICD-VR) were chosen in 25.2%, dual-chamber ICDs in 37.1% (ICD-DR) and biventricular ICDs (CRT-D) in 37.6%, respectively. Complications related to ICD implantation occurred in about 7.49% of all procedures. During follow-up period death occurred in 14.8% of our patients. Also, 13.3% of patients received ICD shock which was appropriate in 71% of patients.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>In comparison between our registry and NCDR registry, baseline patient characteristics and ICD type were almost the same, but the complication rate was higher. There is still a need to perform a large multicenter registry in our community to improve our knowledge in this Era.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/hpc.0000000000000211","type":"journal-article","created":{"date-parts":[[2020,2,6]],"date-time":"2020-02-06T22:48:29Z","timestamp":1581029309000},"page":"90-93","source":"Crossref","is-referenced-by-count":0,"title":["Yazd Province of Iran ICD Registry for the Years 2014\u20132016"],"prefix":"10.1097","volume":"19","author":[{"given":"Maliheh","family":"Malekpour","sequence":"first","affiliation":[{"name":"Yazd Cardiovascular Research Center, Shahid Sadoughi University of Medical Sciences, Yazd, Iran"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Faezeh","family":"Dehghani-Tafti","sequence":"additional","affiliation":[{"name":"Yazd Cardiovascular Research Center, Shahid Sadoughi University of Medical Sciences, Yazd, Iran"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Seid Kazem Razavi","family":"Ratki","sequence":"additional","affiliation":[{"name":"Department of Radiology, Faculty of Medicine, Shahid Sadoughi University of Medical Sciences, Yazd, Iran"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zeinolabedin","family":"Seifpoor","sequence":"additional","affiliation":[{"name":"Yazd Cardiovascular Research Center, Shahid Sadoughi University of Medical Sciences, Yazd, Iran"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nasim","family":"Namiranian","sequence":"additional","affiliation":[{"name":"Yazd Diabetes Research Center, Shahid Sadoughi University of Medical Sciences, Yazd, Iran."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mohammad","family":"Shafiee","sequence":"additional","affiliation":[{"name":"Yazd Cardiovascular Research Center, Shahid Sadoughi University of Medical Sciences, Yazd, Iran"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shahryar","family":"Mali","sequence":"additional","affiliation":[{"name":"Yazd Cardiovascular Research Center, Shahid Sadoughi University of Medical Sciences, Yazd, Iran"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Seyed-Mostafa","family":"Seyed Hosseini","sequence":"additional","affiliation":[{"name":"Yazd Cardiovascular Research Center, Shahid Sadoughi University of Medical Sciences, Yazd, Iran"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20230912","doi-asserted-by":"crossref","first-page":"877","DOI":"10.1056\/NEJMoa013474","article-title":"Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction.","volume":"346","author":"Moss","year":"2002","journal-title":"N Engl J Med"},{"key":"R2-20230912","doi-asserted-by":"crossref","first-page":"2151","DOI":"10.1056\/NEJMoa033088","article-title":"Prophylactic defibrillator implantation in patients with nonischemic dilated cardiomyopathy.","volume":"350","author":"Kadish","year":"2004","journal-title":"N Engl J Med"},{"key":"R3-20230912","doi-asserted-by":"crossref","first-page":"1845","DOI":"10.1056\/NEJMoa013168","article-title":"Cardiac resynchronization in chronic heart failure.","volume":"346","author":"Abraham","year":"2002","journal-title":"N Engl J Med"},{"key":"R4-20230912","doi-asserted-by":"crossref","first-page":"1576","DOI":"10.1056\/NEJM199711273372202","article-title":"A comparison of antiarrhythmic-drug therapy with implantable defibrillators in patients resuscitated from near-fatal ventricular arrhythmias.","volume":"337","year":"1997","journal-title":"N Engl J Med"},{"key":"R6-20230912","doi-asserted-by":"crossref","first-page":"383","DOI":"10.1161\/CIRCULATIONAHA.112.000762","article-title":"Present guidelines for device implantation: clinical considerations and clinical challenges from pacing, implantable cardiac defibrillator, and cardiac resynchronization therapy.","volume":"129","author":"Poole","year":"2014","journal-title":"Circulation"},{"key":"R7-20230912","doi-asserted-by":"crossref","first-page":"470","DOI":"10.1016\/j.hrthm.2006.01.019","article-title":"The National ICD Registry: now and into the future.","volume":"3","author":"Hammill","year":"2006","journal-title":"Heart Rhythm"},{"key":"R8-20230912","doi-asserted-by":"crossref","first-page":"1427","DOI":"10.1016\/j.jacc.2016.12.005","article-title":"Trends in U.S. cardiovascular care: 2016 Report From 4 ACC national cardiovascular data registries.","volume":"69","author":"Masoudi","year":"2017","journal-title":"J Am Coll Cardiol"},{"key":"R9-20230912","doi-asserted-by":"crossref","first-page":"774","DOI":"10.1016\/j.jacc.2009.11.029","article-title":"Evaluation of early complications related to De Novo cardioverter defibrillator implantation insights from the Ontario ICD database.","volume":"55","author":"Lee","year":"2010","journal-title":"J Am Coll Cardiol"},{"key":"R10-20230912","doi-asserted-by":"crossref","first-page":"2069","DOI":"10.1161\/CIRCULATIONAHA.110.959676","article-title":"Implantable cardioverter-defibrillator registry risk score models for acute procedural complications or death after implantable cardioverter-defibrillator implantation.","volume":"123","author":"Haines","year":"2011","journal-title":"Circulation"},{"key":"R11-20230912","doi-asserted-by":"crossref","first-page":"e6","DOI":"10.1016\/j.jacc.2012.11.007","article-title":"2012 ACCF\/AHA\/HRS focused update incorporated into the ACCF\/AHA\/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities: a report of the American College of Cardiology Foundation\/American Heart Association Task Force on Practice Guidelines and the Heart Rhythm Society.","volume":"61","author":"Tracy","year":"2013","journal-title":"J Am Coll Cardiol"},{"key":"R12-20230912","doi-asserted-by":"crossref","first-page":"2793","DOI":"10.1093\/eurheartj\/ehv316","article-title":"2015 ESC Guidelines for the management of patients with ventricular arrhythmias and the prevention of sudden cardiac death: the task force for the management of patients with ventricular arrhythmias and the prevention of sudden cardiac death of the European Society of Cardiology (ESC) Endorsed by: Association for European Paediatric and Congenital Cardiology (AEPC).","volume":"36","author":"Priori","year":"2015","journal-title":"Eur Heart J"},{"key":"R13-20230912","first-page":"1047","article-title":"Spanish Implantable Cardioverter-defibrillator Registry. 14th Official Report of the Spanish Society of Cardiology Electrophysiology and Arrhythmias Section (2017).","volume":"71","author":"Lozano","year":"2018","journal-title":"Rev Esp Cardiol (Engl Ed)"},{"key":"R14-20230912","doi-asserted-by":"crossref","first-page":"465","DOI":"10.1093\/europace\/eun370","article-title":"Impact of the main implantable cardioverter-defibrillator trials in clinical practice: data from the Italian ICD Registry for the years 2005-07.","volume":"11","author":"Proclemer","year":"2009","journal-title":"Europace"},{"key":"R15-20230912","doi-asserted-by":"crossref","first-page":"e59","DOI":"10.1016\/j.hrthm.2013.01.035","article-title":"The National ICD Registry Report: version 2.1 including leads and pediatrics for years 2010 and 2011.","volume":"10","author":"Kremers","year":"2013","journal-title":"Heart Rhythm"},{"key":"R17-20230912","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1056\/NEJMoa043399","article-title":"Amiodarone or an implantable cardioverter\u2013defibrillator for congestive heart failure.","volume":"352","author":"Bardy","year":"2005","journal-title":"N Engl J Med"},{"key":"R18-20230912","doi-asserted-by":"crossref","first-page":"1707","DOI":"10.1016\/S0735-1097(03)00297-3","article-title":"Amiodarone versus implantable cardioverter-defibrillator:randomized trial in patients with nonischemic dilated cardiomyopathy and asymptomatic nonsustained ventricular tachycardia\u2013AMIOVIRT.","volume":"41","author":"Strickberger","year":"2003","journal-title":"J Am Coll Cardiol"},{"key":"R19-20230912","doi-asserted-by":"crossref","first-page":"2140","DOI":"10.1056\/NEJMoa032423","article-title":"Cardiac-resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure.","volume":"350","author":"Bristow","year":"2004","journal-title":"N Engl J Med"},{"key":"R20-20230912","doi-asserted-by":"crossref","first-page":"1260","DOI":"10.1016\/j.hrthm.2007.07.021","article-title":"Review of the registry\u2019s first year, data collected, and future plans.","volume":"4","author":"Hammill","year":"2007","journal-title":"Heart Rhythm"},{"key":"R21-20230912","doi-asserted-by":"crossref","first-page":"e000198","DOI":"10.1136\/openhrt-2014-000198","article-title":"A systematic review of ICD complications in randomised controlled trials versus registries: is our \u2018real-world\u2019 data an underestimation?","volume":"2","author":"Ezzat","year":"2015","journal-title":"Open Heart"},{"key":"R22-20230912","doi-asserted-by":"crossref","first-page":"1186","DOI":"10.1093\/eurheartj\/eht511","article-title":"Complications after cardiac implantable electronic device implantations: an analysis of a complete, nationwide cohort in Denmark.","volume":"35","author":"Kirkfeldt","year":"2014","journal-title":"Eur Heart J"},{"key":"R23-20230912","doi-asserted-by":"crossref","first-page":"110","DOI":"10.15420\/AER.2016.12.2","article-title":"The Significance of Shocks in Implantable cardioverter defibrillator recipients.","volume":"5","author":"Li","year":"2016","journal-title":"Arrhythm Electrophysiol Rev"}],"container-title":["Critical Pathways in Cardiology: A Journal of Evidence-Based Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/HPC.0000000000000211","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,12]],"date-time":"2023-09-12T08:19:05Z","timestamp":1694506745000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/HPC.0000000000000211"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,6]]},"references-count":21,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.1097\/hpc.0000000000000211","relation":{},"ISSN":["1535-282X"],"issn-type":[{"value":"1535-282X","type":"print"}],"subject":[],"published":{"date-parts":[[2020,6]]}}}