{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,10]],"date-time":"2026-04-10T14:41:00Z","timestamp":1775832060418,"version":"3.50.1"},"reference-count":19,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2022,12]]},"abstract":"<jats:sec>\n            <jats:title>Background:<\/jats:title>\n            <jats:p>Remote cardiac monitoring and screening have already become an integral telemedicine component. The wide usage of several different wireless electrocardiography (ECG) devices warrants a validation study on their accuracy and reliability.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>Totally, 300 inpatients with the Nabz Hooshmand-1 handheld ECG device and the GE MAC 1200 ECG system (as the reference) were studied to check the accuracy of the devices in 1 and 6-limb lead performance. Simultaneous 10-second resting ECGs were assessed for the most common ECG parameters in lead I. Afterward, 6-lead ECGs (limb leads), were performed immediately and studied for their morphologies.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>Of the 300 patients, 297 had acceptable ECG quality in both devices for simultaneous lead I ECGs. The ECGs were inspected on-screen by a cardiologist for their rhythms, rates, axes, numbers, morphologies of premature atrial and ventricular beats, morphologies and amplitudes of PQRST waves, P-wave durations, QRS-wave durations, P-R intervals, and QT intervals. No significant differences were detected between the devices, and no major abnormalities were missed. Six-limb lead ECGs were obtained in 284 patients, of whom 281 had acceptable quality in ECGs by both devices. The morphology matching evaluation of the ECGs demonstrated an overall 98% compatibility rate, with the highest compatibility in lead I and the lowest in lead augmented vector foot.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>The diagnosis of critical pathological rhythms, including atrial fibrillation and high-grade atrioventricular node block, was not missed by the Nabz Hooshmand-1 and GE MAC 1200 ECG devices. Accordingly, rhythm detection as the primary purpose of handheld ECG devices was highly accurate. Both devices had acceptable sensitivity to diagnose long P-R and long and short QT intervals. Although the modern technology of smartphones and the physical inability for the 6-limb mode might cause old patients difficulty in utilizing such devices, their use for screening and follow-up is safe.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/hpc.0000000000000303","type":"journal-article","created":{"date-parts":[[2022,11,28]],"date-time":"2022-11-28T14:00:21Z","timestamp":1669644021000},"page":"165-171","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["Clinical Validation of a Smartphone-based Handheld ECG Device: A Validation Study"],"prefix":"10.1097","volume":"21","author":[{"given":"Sajjad","family":"Ahmadi-Renani","sequence":"first","affiliation":[{"name":"Tehran Heart Center, Tehran University of Medical Sciences, Tehran, Iran"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Milad","family":"Gharebaghi","sequence":"additional","affiliation":[{"name":"Tehran University of Medical Sciences, Tehran, Iran"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Erfan","family":"Kamalian","sequence":"additional","affiliation":[{"name":"Department of Electrical Engineering, Sharif University of Technology, Tehran, Iran"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hassan","family":"Hajghassem","sequence":"additional","affiliation":[{"name":"Faculty of New Sciences and Technologies, University of Tehran, Tehran, Iran"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Abolfazl","family":"Ghanbari","sequence":"additional","affiliation":[{"name":"Department of Computer Engineering, Sharif University of Technology, Tehran, Iran"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alireza","family":"Karimi","sequence":"additional","affiliation":[{"name":"Department of Electrical and Computer Engineering, Qom University of Technology, Qom, Iran"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bahman","family":"Mansoury","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, Sharif University of Technology, Tehran, Iran"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mohammad Saeed","family":"Dayari","sequence":"additional","affiliation":[{"name":"Department of Electrical Engineering, KN Toosi University of Technology, Tehran, Iran"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mahdi","family":"Khatmi Nemati","sequence":"additional","affiliation":[{"name":"Iran University of Science and Technology, Tehran, Iran"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Armin","family":"Karimi","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, Iran University of Science and Technology, Tehran, Iran"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mohammad Hosein","family":"Zarghami","sequence":"additional","affiliation":[{"name":"University of Science and Research, Tehran, Iran"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ali","family":"Vasheghani-Farahani","sequence":"additional","affiliation":[{"name":"Cardiac Primary Prevention Research Center, Cardiovascular Diseases Research Institute, Tehran University of Medical Sciences, Tehran, Iran."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2022,11,1]]},"reference":[{"key":"R1-20250506","doi-asserted-by":"crossref","first-page":"14383","DOI":"10.3402\/jchimp.v2i1.14383","article-title":"A brief review: history to understand fundamentals of electrocardiography.","volume":"2","author":"AlGhatrif","year":"2012","journal-title":"J Community Hosp Intern Med Perspect"},{"key":"R2-20250506","doi-asserted-by":"crossref","first-page":"593","DOI":"10.1007\/s40266-013-0094-8","article-title":"Atrial fibrillation in the elderly.","volume":"30","author":"Nantsupawat","year":"2013","journal-title":"Drugs Aging"},{"key":"R3-20250506","doi-asserted-by":"crossref","first-page":"e000479","DOI":"10.1161\/JAHA.113.000479","article-title":"Impact of atrial fibrillation on stroke-related healthcare costs.","volume":"2","author":"Sussman","year":"2013","journal-title":"J Am Heart Assoc"},{"key":"R4-20250506","doi-asserted-by":"crossref","first-page":"213","DOI":"10.1160\/TH13-02-0165","article-title":"Screening to identify unknown atrial fibrillation: a systematic review.","volume":"110","author":"Lowres","year":"2013","journal-title":"Thromb Haemost"},{"key":"R5-20250506","doi-asserted-by":"crossref","first-page":"e21388","DOI":"10.1097\/MD.0000000000021388","article-title":"Effectiveness of a single lead AliveCor electrocardiogram application for the screening of atrial fibrillation: a systematic review.","volume":"99","author":"Hall","year":"2020","journal-title":"Medicine"},{"key":"R6-20250506","doi-asserted-by":"crossref","first-page":"1784","DOI":"10.1161\/CIRCULATIONAHA.117.030583","article-title":"Assessment of remote heart rhythm sampling using the AliveCor heart monitor to screen for atrial fibrillation the REHEARSE-AF study.","volume":"136","author":"Halcox","year":"2017","journal-title":"Circulation"},{"key":"R7-20250506","doi-asserted-by":"crossref","first-page":"964","DOI":"10.1177\/2047487319839184","article-title":"Cost-effectiveness and screening performance of ECG handheld machine in a population screening programme: the Belgian Heart Rhythm Week screening programme.","volume":"26","author":"Proietti","year":"2019","journal-title":"Eur J Prev Cardiol"},{"key":"R8-20250506","first-page":"12","article-title":"Cost-effectiveness of screening for atrial fibrillation in primary care with a handheld, single-lead electrocardiogram device in the Netherlands.","volume":"20","author":"Jacobs","year":"2018","journal-title":"Europace"},{"key":"R9-20250506","doi-asserted-by":"crossref","first-page":"520","DOI":"10.1111\/jce.12634","article-title":"Wireless smartphone ECG enables large-scale screening in diverse populations.","volume":"26","author":"Haberman","year":"2015","journal-title":"J Cardiovasc Electrophysiol"},{"key":"R10-20250506","doi-asserted-by":"crossref","first-page":"44","DOI":"10.1093\/ejcts\/ezv486","article-title":"Self-monitoring for atrial fibrillation recurrence in the discharge period post-cardiac surgery using an iPhone electrocardiogram.","volume":"50","author":"Lowres","year":"2016","journal-title":"Eur J Cardiothorac Surg"},{"key":"R11-20250506","doi-asserted-by":"crossref","first-page":"bcr-2016","DOI":"10.1136\/bcr-2016-217197","article-title":"Supraventricular tachycardia diagnosed by smartphone ECG.","volume":"2017","author":"Tabing","year":"2017","journal-title":"BMJ Case Reports"},{"key":"R12-20250506","doi-asserted-by":"crossref","first-page":"2220","DOI":"10.1111\/jce.14160","article-title":"Recurrent atrial fibrillation\/flutter detection after ablation or cardioversion using the AliveCor KardiaMobile device: iHEART results.","volume":"30","author":"Goldenthal","year":"2019","journal-title":"J Cardiovasc Electrophysiol"},{"key":"R13-20250506","doi-asserted-by":"crossref","first-page":"827","DOI":"10.1111\/jce.12976","article-title":"Comparison of QT interval readings in normal sinus rhythm between a smartphone heart monitor and a 12-lead ECG for healthy volunteers and inpatients receiving sotalol or dofetilide.","volume":"27","author":"Garabelli","year":"2016","journal-title":"J Cardiovasc Electrophysiol"},{"key":"R14-20250506","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1016\/j.eclinm.2019.02.005","article-title":"Multi-centre randomised controlled trial of a smartphone-based event recorder alongside standard care versus standard care for patients presenting to the emergency department with palpitations and pre-syncope: the IPED (Investigation of Palpitations in the ED) study.","volume":"8","author":"Reed","year":"2019","journal-title":"EClinicalMedicine"},{"key":"R15-20250506","doi-asserted-by":"crossref","first-page":"697","DOI":"10.1515\/med-2020-0203","article-title":"72 hour Holter monitoring, 7 day Holter monitoring, and 30 day intermittent patient-activated heart rhythm recording in detecting arrhythmias in cryptogenic stroke patients free from arrhythmia in a screening 24\u2009h Holter.","volume":"15","author":"Ku\u0142ach","year":"2020","journal-title":"Open Med"},{"key":"R16-20250506","doi-asserted-by":"crossref","first-page":"355","DOI":"10.1002\/clc.23323","article-title":"Intermittent vs continuous electrocardiogram event recording for detection of atrial fibrillation\u2014compliance and ease of use in an ambulatory elderly population.","volume":"43","author":"Fredriksson","year":"2020","journal-title":"Clin Cardiol"},{"key":"R17-20250506","doi-asserted-by":"crossref","first-page":"1726","DOI":"10.18203\/2394-6040.ijcmph20201971","article-title":"A comparative study to evaluate the clinical utility and performance of a new hand-held mobile electrocardiogram device.","volume":"7","author":"Desai","year":"2020","journal-title":"Int J Community Med Public Health"},{"key":"R18-20250506","doi-asserted-by":"crossref","first-page":"96","DOI":"10.3390\/healthcare7030096","article-title":"Mobile self-monitoring ECG devices to diagnose arrhythmia that coincide with palpitations: a scoping review.","volume":"7","author":"Marston","year":"2019","journal-title":"Healthcare"},{"key":"R19-20250506","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1016\/j.ijge.2015.06.002","article-title":"Utilization and clinical feasibility of a handheld remote electrocardiography recording device in cardiac arrhythmias and atrial fibrillation: a pilot study.","volume":"9","author":"Chang","year":"2015","journal-title":"Int J Gerontol"}],"container-title":["Critical Pathways in Cardiology: A Journal of Evidence-Based Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/HPC.0000000000000303","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,6]],"date-time":"2025-05-06T19:02:49Z","timestamp":1746558169000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/HPC.0000000000000303"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,11,1]]},"references-count":19,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.1097\/hpc.0000000000000303","relation":{},"ISSN":["1535-2811"],"issn-type":[{"value":"1535-2811","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,11,1]]}}}