{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,31]],"date-time":"2026-03-31T19:52:16Z","timestamp":1774986736839,"version":"3.50.1"},"reference-count":19,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,12]]},"abstract":"<jats:p>Approximately 20%\u201340% of patients that present for transcatheter aortic valve replacement with a balloon-expandable transcatheter heart valve (THV) fall into a borderline aortic annulus size (BAAS). There are potential benefits to overexpanding an undersized THV (OE-THV) in such cases that include reduced electrical disturbances and annular injury at the expense of increased paravalvular leak (PVL). We conducted a meta-analysis of data comparing conventional-sized versus OE-THV strategy for BAAS and reviewed the literature for balloon-expandable-THV in such cases. 9 nonrandomized studies that compared a conventional strategy to OE-THV in patients with BAAS were included in our study. Our findings suggest that there is no difference in mortality, stroke, mean gradient, or significant PVL. There was a trend towards fewer pacemakers in patients receiving an OE-THV. Borderline aortic annulus measurements are common in patients undergoing transcatheter aortic valve replacement and there appears to be equipoise between conventional sizing versus OE-THV. Future detailed studies are required to evaluate short- and long-term outcomes among strategies.<\/jats:p>","DOI":"10.1097\/hpc.0000000000000392","type":"journal-article","created":{"date-parts":[[2025,7,1]],"date-time":"2025-07-01T11:02:41Z","timestamp":1751367761000},"page":"e0392","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Evaluating Outcomes of Overexpanding Versus Conventional Sizing in Transcatheter Aortic Valve Replacement for Borderline Aortic Annulus: A Meta-Analysis"],"prefix":"10.1097","volume":"24","author":[{"given":"Ahmad","family":"Mustafa","sequence":"first","affiliation":[{"name":"Department of Cardiology and Cardiothoracic Surgery, Hackensack University Medical Center, New Jersey, USA"},{"name":"Department of Cardiology and Cardiothoracic Surgery, Northwell Health, New York, USA."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ryan","family":"Kaple","sequence":"additional","affiliation":[{"name":"Department of Cardiology and Cardiothoracic Surgery, Hackensack University Medical Center, New Jersey, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chapman","family":"Wei","sequence":"additional","affiliation":[{"name":"Department of Cardiology and Cardiothoracic Surgery, Northwell Health, New York, USA."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yuriy","family":"Dudiy","sequence":"additional","affiliation":[{"name":"Department of Cardiology and Cardiothoracic Surgery, Hackensack University Medical Center, New Jersey, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sung-Han","family":"Yoon","sequence":"additional","affiliation":[{"name":"Department of Cardiology and Cardiothoracic Surgery, Hackensack University Medical Center, New Jersey, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Perry","family":"Wengrofsky","sequence":"additional","affiliation":[{"name":"Department of Cardiology and Cardiothoracic Surgery, Hackensack University Medical Center, New Jersey, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Vladimir","family":"Jelnin","sequence":"additional","affiliation":[{"name":"Department of Cardiology and Cardiothoracic Surgery, Hackensack University Medical Center, New Jersey, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"George","family":"Batsides","sequence":"additional","affiliation":[{"name":"Department of Cardiology and Cardiothoracic Surgery, Hackensack University Medical Center, New Jersey, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rachel","family":"Spallone","sequence":"additional","affiliation":[{"name":"Department of Cardiology and Cardiothoracic Surgery, Hackensack University Medical Center, New Jersey, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Elie","family":"Elmann","sequence":"additional","affiliation":[{"name":"Department of Cardiology and Cardiothoracic Surgery, Hackensack University Medical Center, New Jersey, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mark","family":"Anderson","sequence":"additional","affiliation":[{"name":"Department of Cardiology and Cardiothoracic Surgery, Hackensack University Medical Center, New Jersey, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David","family":"Landers","sequence":"additional","affiliation":[{"name":"Department of Cardiology and Cardiothoracic Surgery, Hackensack University Medical Center, New Jersey, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Craig","family":"Basman","sequence":"additional","affiliation":[{"name":"Department of Cardiology and Cardiothoracic Surgery, Hackensack University Medical Center, New Jersey, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2025,6,26]]},"reference":[{"key":"R1-20260331","doi-asserted-by":"crossref","first-page":"2739","DOI":"10.1093\/eurheartj\/ehx391","article-title":"2017 ESC\/EACTS guidelines for the management of valvular heart disease.","volume":"38","author":"Baumgartner","year":"2017","journal-title":"Eur Heart J"},{"key":"R2-20260331","first-page":"415","article-title":"Comparison of clinical outcomes between use of overexpanding an undersized versus nominal-sized Sapien 3 ultra transcatheter heart valve in patients with borderline annulus area.","volume":"100","author":"Basman","year":"2022","journal-title":"Catheter Cardiovasc Interv"},{"key":"R3-20260331","first-page":"263","article-title":"Larger or smaller, which size of balloon expandable transcatheter aortic valve is better for border zone aortic annulus?","volume":"14","author":"Kawaguchi","year":"2022","journal-title":"Interv Cardiol"},{"key":"R4-20260331","doi-asserted-by":"crossref","first-page":"1125","DOI":"10.1016\/j.jacc.2012.08.1039","article-title":"Paravalvular leak after transcatheter aortic valve replacement: the new Achilles\u2019 heel? A comprehensive review of the literature.","volume":"61","author":"G\u00e9n\u00e9reux","year":"2013","journal-title":"J Am Coll Cardiol"},{"key":"R5-20260331","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.jcin.2014.07.020","article-title":"Annular rupture during transcatheter aortic valve replacement: classification, pathophysiology, diagnostics, treatment approaches, and prevention.","volume":"8","author":"Pasic","year":"2015","journal-title":"JACC Cardiovasc Interv"},{"key":"R6-20260331","doi-asserted-by":"crossref","first-page":"847259","DOI":"10.3389\/fcvm.2022.847259","article-title":"Impact of valve size on paravalvular leak and valve hemodynamics in patients with borderline size aortic valve annulus.","volume":"9","author":"Talmor-Barkan","year":"2022","journal-title":"Front Cardiovasc Med"},{"key":"R7-20260331","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1016\/j.carrev.2024.03.030","article-title":"Outcomes and treatment strategy of transcatheter aortic valve replacement with balloon-expandable valve in borderline-size annulus.","volume":"66","author":"Isogai","year":"2024","journal-title":"Cardiovasc Revasc Med"},{"key":"R8-20260331","first-page":"E768","article-title":"Heart valve sizing and clinical outcomes in patients undergoing transcatheter aortic valve implantation.","volume":"98","author":"Okuno","year":"2021","journal-title":"Catheter Cardiovasc Interv"},{"key":"R9-20260331","doi-asserted-by":"crossref","first-page":"e012554","DOI":"10.1161\/CIRCINTERVENTIONS.122.012554","article-title":"Optimal degree of balloon-expandable transcatheter valve oversizing in patients with borderline aortic annulus measurements: insights from a multicenter real-world experience.","volume":"16","author":"Panagides","year":"2023","journal-title":"Circ Cardiovasc Interv"},{"key":"R10-20260331","first-page":"100593","article-title":"Undersizing but overfilling eliminates the gray zones of sizing for transcatheter aortic valve replacement with the balloon-expandable bioprosthesis.","volume":"30","author":"Patsalis","year":"2020","journal-title":"Int J Cardiol Heart Vasc"},{"key":"R11-20260331","first-page":"23","article-title":"Avoiding s3 valve over-sizing by deployment balloon over-filling: impact on rates of permanent pacemaker and other procedural complications during TAVR.","volume":"30","author":"Sheth","year":"2018","journal-title":"J Invasive Cardiol"},{"key":"R12-20260331","doi-asserted-by":"crossref","first-page":"463","DOI":"10.1016\/j.jcin.2021.11.032","article-title":"Outcomes of Sapien 3 ultra TAVR in extremely undersized versus equivalent nominally sized anatomies.","volume":"15","author":"Tang","year":"2022","journal-title":"JACC Cardiovasc Interv"},{"key":"R13-20260331","doi-asserted-by":"crossref","first-page":"189","DOI":"10.14744\/AnatolJCardiol.2022.2558","article-title":"Evaluation of the transcatheter aortic valve replacement results in patients with borderline aortic annulus and the impact of under- or oversizing the valve.","volume":"27","author":"Yildirim","year":"2023","journal-title":"Anatol J Cardiol"},{"key":"R14-20260331","first-page":"2082","article-title":"Efficacy of larger valve sizing with underfilling in balloon-expandable transcatheter aortic valve replacement.","volume":"99","author":"Kawaguchi","year":"2022","journal-title":"Catheter Cardiovasc Interv"},{"key":"R15-20260331","doi-asserted-by":"crossref","first-page":"244","DOI":"10.1161\/CIRCULATIONAHA.113.002947","article-title":"Anatomical and procedural features associated with aortic root rupture during balloon-expandable transcatheter aortic valve replacement.","volume":"128","author":"Barbanti","year":"2013","journal-title":"Circulation"},{"key":"R16-20260331","doi-asserted-by":"crossref","first-page":"351","DOI":"10.1016\/j.jjcc.2024.02.011","article-title":"Deformation in transcatheter heart valves: clinical implications and considerations.","volume":"83","author":"Fukui","year":"2024","journal-title":"J Cardiol"},{"key":"R17-20260331","doi-asserted-by":"crossref","first-page":"2041","DOI":"10.1016\/j.jcin.2015.10.006","article-title":"Overexpansion of the Sapien 3 transcatheter heart valve: a feasibility study.","volume":"8","author":"Shivaraju","year":"2015","journal-title":"JACC Cardiovasc Interv"},{"key":"R18-20260331","first-page":"101937","article-title":"Computed tomography geometry of extremely undersized sapien 3 transcatheter aortic valves with balloon overfilling.","volume":"3","author":"Tanner","year":"2024","journal-title":"J Soc Cardiovasc Angiogr Interv"},{"key":"R19-20260331","doi-asserted-by":"crossref","first-page":"e013497","DOI":"10.1161\/CIRCINTERVENTIONS.123.013497","article-title":"Feasibility of redo-transcatheter aortic valve replacement in sapien valves based on in vivo computed tomography assessment.","volume":"16","author":"Fukui","year":"2023","journal-title":"Circ Cardiovasc Interv"}],"container-title":["Critical Pathways in Cardiology: A Journal of Evidence-Based Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/HPC.0000000000000392","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,31]],"date-time":"2026-03-31T19:01:47Z","timestamp":1774983707000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/HPC.0000000000000392"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,6,26]]},"references-count":19,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/hpc.0000000000000392","relation":{},"ISSN":["1535-2811"],"issn-type":[{"value":"1535-2811","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,6,26]]}}}