{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,16]],"date-time":"2026-10-16T06:30:31Z","timestamp":1792132231212,"version":"4.4.0"},"reference-count":10,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2018,9]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>To describe surgical outcomes and structural characteristics of intraocular lenses (IOLs) implanted with transconjunctival sutureless intrascleral (SIS) fixation in human eyes.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Design:<\/jats:title>\n            <jats:p>Retrospective interventional surgical case series involving live and cadaveric human eyes.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>In this study, we investigated the surgical outcomes and structural anatomy of secondary IOLs implanted with the SIS technique in human eyes. All cases involving SIS IOL fixation performed at a single academic center from January 1, 2012, through July 30, 2016, were reviewed to describe the surgical technique, common indications, clinical outcomes, and the rate of common operative complications. To investigate the structure of SIS-fixated IOLs in vivo, slit-lamp biomicroscopy, ultrasound biomicroscopy, and intraoperative endoscopy were analyzed to describe anatomical outcomes. The primary anatomical outcomes were the optic pupillary centration and location of haptic externalization. Results were correlated with cadaveric human eyes that underwent the SIS-IOL technique. Cadaveric eyes were imaged and analyzed using high-resolution photography for centration, stress measurements at the haptic\u2013optic junction, and qualitative descriptors of IOL optic and haptic position.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>A total of 122 consecutive patients who underwent IOL placement using SIS technique were included in the study with mean follow-up of 1.52 years (range, 0.4\u20134.5 years). The majority (75%) of patients received a new 3-piece IOL for primary aphakia or after IOL exchange. The other patients (25%) had a dislocated 3-piece IOL that was rescued using the SIS technique. Preoperative mean Snellen visual acuity was 20\/633 (logarithm of the minimum angle of resolution = 1.501). At the final visit, the mean best-corrected visual acuity was 20\/83 (logarithm of the minimum angle of resolution = 0.6243) and final mean spherical equivalent was \u22120.57 diopters. The most common complications were vitreous hemorrhage (22% of eyes), which resolved spontaneously in most cases, and cystoid macular edema. The rates of IOL dislocation, IOL decentration, haptic erosion, IOL tilting, iris capture, and endophthalmitis were low. Intraoperative endoscopy and ultrasound biomicroscopy demonstrated a securely fixated IOL and well-centered optic without iris or ciliary body touch. Structural study of cadaveric eyes confirmed IOL optic and haptic anatomy observed during live human surgery. The ab interno haptic insertion was the anterior pars plana, away from the iris, ciliary processes and ora serrata. The degree of haptic externalization was correlated with the degree of strain on the haptic\u2013optic junction. The angle of the haptic\u2013optic junction in SIS-fixated IOLs (33.97\u00b0) was not significantly different compared with overlaid native nonfixated IOL (32.93\u00b0) but increased slightly with degree of haptic tip externalization (36.26 and 39.16<jats:sup>o<\/jats:sup> for 2 and 3 mm haptic externalizations, respectively).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion:<\/jats:title>\n            <jats:p>In this comprehensive study, we demonstrate the surgical outcomes achieved with SIS fixation of IOLs. Surgical and postoperative complications do occur, albeit at a low rate, and can effectively be managed with excellent anatomical and visual outcomes. The structural and anatomical data in this study may help guide SIS placement and optimize long-term surgical results.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/iae.0000000000001941","type":"journal-article","created":{"date-parts":[[2017,12,12]],"date-time":"2017-12-12T20:20:37Z","timestamp":1513110037000},"page":"S31-S40","source":"Crossref","is-referenced-by-count":64,"title":["STRUCTURAL ANALYSIS AND COMPREHENSIVE SURGICAL OUTCOMES OF THE SUTURELESS INTRASCLERAL FIXATION OF SECONDARY INTRAOCULAR LENSES IN HUMAN EYES"],"prefix":"10.1097","volume":"38","author":[{"given":"Bozho","family":"Todorich","sequence":"first","affiliation":[{"name":"Department of Ophthalmology, Oakland University William Beaumont School of Medicine, Royal Oak, Michigan; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maxwell S.","family":"Stem","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Oakland University William Beaumont School of Medicine, Royal Oak, Michigan; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Keshav","family":"Kooragayala","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Oakland University William Beaumont School of Medicine, Royal Oak, Michigan; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aristomenis","family":"Thanos","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Oakland University William Beaumont School of Medicine, Royal Oak, Michigan; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lisa J.","family":"Faia","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Oakland University William Beaumont School of Medicine, Royal Oak, Michigan; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"George A.","family":"Williams","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Oakland University William Beaumont School of Medicine, Royal Oak, Michigan; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tarek S.","family":"Hassan","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Oakland University William Beaumont School of Medicine, Royal Oak, Michigan; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maria A.","family":"Woodward","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology and Visual Sciences, Kellogg Eye Center, University of Michigan, Ann Arbor, Michigan."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jeremy D.","family":"Wolfe","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Oakland University William Beaumont School of Medicine, Royal Oak, Michigan; and"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20230816","doi-asserted-by":"crossref","first-page":"247","DOI":"10.1016\/S0886-3350(96)80227-6","article-title":"Secondary implantation of angle-supported anterior chamber and scleral-fixated posterior chamber intraocular lenses","volume":"22","author":"Bellucci","year":"1996","journal-title":"J Cataract Refract Surg"},{"key":"R2-20230816","doi-asserted-by":"crossref","first-page":"254","DOI":"10.1016\/j.jcrs.2009.09.024","article-title":"Intermediate results of sutureless intrascleral posterior chamber intraocular lens fixation","volume":"36","author":"Scharioth","year":"2010","journal-title":"J Cataract Refract Surg"},{"key":"R3-20230816","doi-asserted-by":"crossref","first-page":"1479","DOI":"10.1016\/j.ophtha.2009.12.043","article-title":"Outcomes of iris-claw anterior chamber versus iris-fixated foldable intraocular lens in subluxated lens secondary to Marfan syndrome","volume":"117","author":"Hirashima","year":"2010","journal-title":"Ophthalmology"},{"key":"R4-20230816","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/s00417-014-2834-9","article-title":"Sutureless scleral fixation of intraocular lenses: outcomes of two approaches. The 2014 Yasuo Tano memorial lecture","volume":"253","author":"Abbey","year":"2015","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"R5-20230816","doi-asserted-by":"crossref","first-page":"376","DOI":"10.3928\/23258160-20160324-14","article-title":"Sutureless intrascleral fixation of secondary intraocular lens using 27-gauge vitrectomy system","volume":"47","author":"Todorich","year":"2016","journal-title":"Ophthalmic Surg Lasers Imaging Retina"},{"key":"R6-20230816","doi-asserted-by":"crossref","first-page":"853","DOI":"10.1097\/IAE.0b013e3182479b61","article-title":"A novel approach for posterior chamber intraocular lens placement or rescue via a sutureless scleral fixation technique","volume":"32","author":"Prenner","year":"2012","journal-title":"Retina"},{"key":"R7-20230816","doi-asserted-by":"crossref","first-page":"657","DOI":"10.1097\/IAE.0b013e31827b6499","article-title":"Transconjunctival sutureless haptic fixation of posterior chamber IOL: a minimally traumatic approach for IOL rescue or secondary implantation","volume":"33","author":"Prasad","year":"2013","journal-title":"Retina"},{"key":"R8-20230816","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1016\/j.ophtha.2013.08.043","article-title":"Sutureless 27-gauge needle-guided intrascleral intraocular lens implantation with lamellar scleral dissection","volume":"121","author":"Yamane","year":"2014","journal-title":"Ophthalmology"},{"key":"R9-20230816","doi-asserted-by":"crossref","first-page":"2051","DOI":"10.1016\/j.jcrs.2009.06.044","article-title":"Needle-guided intrascleral fixation of posterior chamber intraocular lens for aphakia correction","volume":"35","author":"Rodriguez-Agirretxe","year":"2009","journal-title":"J Cataract Refract Surg"},{"key":"R10-20230816","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1097\/IAE.0000000000001257","article-title":"Extraocular technique of intrascleral intraocular lens fixation using a pair of the shaft-bended 27-gauge needles","volume":"37","author":"Maruko","year":"2017","journal-title":"Retina"}],"container-title":["Retina"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00006982-201809001-00006","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,17]],"date-time":"2023-08-17T00:09:27Z","timestamp":1692230967000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00006982-201809001-00006"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,9]]},"references-count":10,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2018]]}},"URL":"https:\/\/doi.org\/10.1097\/iae.0000000000001941","relation":{},"ISSN":["0275-004X"],"issn-type":[{"value":"0275-004X","type":"print"}],"subject":[],"published":{"date-parts":[[2018,9]]}}}