{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,19]],"date-time":"2026-09-19T13:25:41Z","timestamp":1789824341300,"version":"4.0.1"},"reference-count":15,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","license":[{"start":{"date-parts":[[2018,9,1]],"date-time":"2018-09-01T00:00:00Z","timestamp":1535760000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2018,9]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>To report a novel technique for intrascleral fixation of a posterior chamber intraocular lens using a silicone microtube to manipulate the haptics into position.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>Intrascleral fixation was performed in six eyes and the results evaluated in this retrospective case series. A silicone microtube with a 0.2-mm external diameter was passed from a sclerocorneal incision through the chamber and a sclerotomy made using a 30-gauge needle. The tips of the intraocular lens haptics were connected to the silicone microtube outside the eye. After the intraocular lens was injected into the posterior chamber, the haptics were drawn through the scleral incision through their attachment to the silicone microtube.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>The mean postoperative corrected visual acuity was 0.62 logarithm of the minimum angle of resolution (20\/43) with a mean refraction error of \u22120.06 \u00b1 0.4 diopter, which did not differ significantly (<jats:italic toggle=\"yes\">P<\/jats:italic> = 0.53) from the expected value. The postoperative complications included transient ocular hypotension, vitreous hemorrhage, and choroidal detachment.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion:<\/jats:title>\n            <jats:p>Our technique using a silicone microtube reduces the number of intraocular procedures compared with previous methods using forceps or needles for moving the intraocular lens haptics from the posterior chamber to the outside through sclerotomies.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/iae.0000000000002143","type":"journal-article","created":{"date-parts":[[2018,3,21]],"date-time":"2018-03-21T13:23:09Z","timestamp":1521638589000},"page":"S146-S153","source":"Crossref","is-referenced-by-count":9,"title":["SILICONE MICROTUBE\u2013ASSISTED SCLERAL FIXATION OF A POSTERIOR CHAMBER INTRAOCULAR LENS"],"prefix":"10.1097","volume":"38","author":[{"given":"Takuya","family":"Kataoka","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Motohiro","family":"Kamei","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20230816","doi-asserted-by":"crossref","first-page":"1851","DOI":"10.1016\/j.jcrs.2007.07.013","article-title":"Sutureless intrascleral posterior chamber intraocular lens fixation","volume":"33","author":"Gabor","year":"2007","journal-title":"J Cataract Refract Surg"},{"key":"R2-20230816","doi-asserted-by":"crossref","first-page":"1433","DOI":"10.1016\/j.jcrs.2008.04.040","article-title":"Fibrin glue-assisted sutureless posterior chamber intraocular lens implantation in eyes with deficient posterior capsules","volume":"34","author":"Agarwal","year":"2008","journal-title":"J Cataract Refract Surg"},{"key":"R3-20230816","doi-asserted-by":"crossref","first-page":"317","DOI":"10.1016\/j.jcrs.2013.01.019","article-title":"Handshake technique for glued intrascleral haptic fixation of a posterior chamber intraocular lens","volume":"39","author":"Agarwal","year":"2013","journal-title":"J Cataract Refract Surg"},{"key":"R4-20230816","doi-asserted-by":"crossref","first-page":"2051","DOI":"10.1016\/j.jcrs.2009.06.044","article-title":"Needle-guided intrascleral fixation of posterior chamber intraocular lens for aphakia correction","volume":"35","author":"Rodr\u00edguez-Agirretxe","year":"2009","journal-title":"J Cataract Refract Surg"},{"key":"R5-20230816","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1016\/j.jcrs.2012.08.063","article-title":"Sutureless intrascleral intraocular lens implantation after ocular trauma","volume":"39","author":"Saleh","year":"2013","journal-title":"J Cataract Refract Surg"},{"key":"R6-20230816","doi-asserted-by":"crossref","first-page":"1143","DOI":"10.1038\/eye.2010.10","article-title":"Glued posterior chamber IOL in eyes with deficient capsular support: a retrospective analysis of 1-year post-operative outcomes","volume":"24","author":"Kumar","year":"2010","journal-title":"Eye"},{"key":"R7-20230816","doi-asserted-by":"crossref","first-page":"594","DOI":"10.1016\/j.ajo.2011.09.027","article-title":"Glued intrascleral fixation of posterior chamber intra- ocular lens in children","volume":"153","author":"Kumar","year":"2012","journal-title":"Am J Ophthalmol"},{"key":"R8-20230816","doi-asserted-by":"crossref","first-page":"788","DOI":"10.1038\/eye.2012.19","article-title":"Trocar-assisted sutureless intrascleral posterior chamber foldable intra-ocular lens fixation","volume":"26","author":"Totan","year":"2012","journal-title":"Eye"},{"key":"R9-20230816","doi-asserted-by":"crossref","first-page":"254","DOI":"10.1016\/j.jcrs.2009.09.024","article-title":"Intermediate results of sutureless intrascleral posterior chamber intraocular lens fixation","volume":"36","author":"Scharioth","year":"2010","journal-title":"J Cataract Refract Surg"},{"key":"R10-20230816","doi-asserted-by":"crossref","first-page":"1211","DOI":"10.1016\/j.jcrs.2013.03.004","article-title":"Complications and visual outcomes after glued foldable intraocular lens implantation in eyes with inadequate capsules","volume":"39","author":"Kumar","year":"2013","journal-title":"J Cataract Refract Surg"},{"key":"R11-20230816","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1016\/j.jcrs.2012.11.001","article-title":"Modified method of haptic externalization of posterior chamber intraocular lens in fibrin glue-assisted intrascleral fixation: no-assistant technique","volume":"39","author":"Narang","year":"2013","journal-title":"J Cataract Refract Surg"},{"key":"R12-20230816","doi-asserted-by":"crossref","first-page":"323","DOI":"10.1016\/j.jcrs.2013.01.017","article-title":"Modification of externalized haptic support of glued intraocular lens technique","volume":"39","author":"Beiko","year":"2013","journal-title":"J Cataract Refract Surg"},{"key":"R13-20230816","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1016\/j.ophtha.2013.08.043","article-title":"Sutureless 27-gauge needle-guided intrascleral intraocular lens implantation with lamellar scleral dissection","volume":"121","author":"Yamane","year":"2014","journal-title":"Ophthalmology"},{"key":"R14-20230816","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1016\/j.jcrs.2013.11.003","article-title":"Simplified and safe method of sutureless intrascleral posterior chamber intraocular lens fixation: Y-fixation technique","volume":"40","author":"Ohta","year":"2014","journal-title":"J Cataract Refract Surg"},{"key":"R15-20230816","doi-asserted-by":"crossref","first-page":"257","DOI":"10.1016\/j.jcrs.2014.08.030","article-title":"Intrascleral fixation technique using catheter needles and 30-gauge ultrathin needles: lock-and-lead technique","volume":"41","author":"Akimoto","year":"2014","journal-title":"J Cataract Refract Surg"}],"container-title":["Retina"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00006982-201809001-00020","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,17]],"date-time":"2023-08-17T00:09:46Z","timestamp":1692230986000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00006982-201809001-00020"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,9]]},"references-count":15,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2018]]}},"URL":"https:\/\/doi.org\/10.1097\/iae.0000000000002143","relation":{},"ISSN":["0275-004X"],"issn-type":[{"value":"0275-004X","type":"print"}],"subject":[],"published":{"date-parts":[[2018,9]]}}}