{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,3]],"date-time":"2026-03-03T06:20:09Z","timestamp":1772518809855,"version":"3.50.1"},"reference-count":15,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","license":[{"start":{"date-parts":[[2020,1,1]],"date-time":"2020-01-01T00:00:00Z","timestamp":1577836800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2020,1]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>Investigate the effective performance and safety of a new hypersonic vitrector technology.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>Postapproval, prospective, single-arm, noncomparative, open-label study at one clinical site in India. Indications: macular hole (9\/20), vitreous hemorrhage (7\/20), vitreomacular traction (3\/20), and vitreomacular traction with pseudomacular hole (1\/20). Safety endpoints included intraoperative and postoperative adverse events. Effective performance endpoints were surgeon-rated effectiveness, range of surgical time, and device settings. Other performance measures were preoperative and postoperative best-corrected visual acuity, slit-lamp and indirect ophthalmoscopy, applanation tonometry, color fundus photography, fundus fluorescein angiography, and spectral domain optical coherence tomography.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>Core vitreous removal (20\/20 subjects), peripheral vitreous removal (18\/20), and posterior vitreous detachment induction (13\/15) surgeries were successfully completed. Total surgical time was 22.5 minutes to 106 minutes. Serious adverse events through 3 months were 2 device-associated retinal tears and detachment (one intraoperative) and one unrelated postoperative enlargement of macular hole with subretinal fluid.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion:<\/jats:title>\n            <jats:p>This first-in-human study suggests that this new hypersonic vitrector technology is a promising alternative to commercially available guillotine vitrectors. The hypersonic vitrector was effective in core vitreous removal in all cases. Larger-scale studies are required to expand on our initial findings for induction of a posterior vitreous detachment or peripheral vitrectomy.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/iae.0000000000002365","type":"journal-article","created":{"date-parts":[[2018,10,26]],"date-time":"2018-10-26T01:02:43Z","timestamp":1540515763000},"page":"16-23","source":"Crossref","is-referenced-by-count":10,"title":["FIRST-IN-HUMAN CLINICAL STUDY TO INVESTIGATE THE EFFECTIVENESS AND SAFETY OF PARS PLANA VITRECTOMY SURGERY USING A NEW HYPERSONIC TECHNOLOGY"],"prefix":"10.1097","volume":"40","author":[{"given":"Paulo E.","family":"Stanga","sequence":"first","affiliation":[{"name":"Manchester Academic Health Science Centre, Manchester Royal Eye Hospital, Manchester University NHS Foundation Trust, Manchester, United Kingdom;"},{"name":"Manchester Vision Regeneration Lab, Manchester Academic Health Science Centre, Manchester University NHS Foundation Trust, Manchester, United Kingdom;"},{"name":"Division of Evolution and Genomic Sciences, School of Biological Sciences, Faculty of Biology, Medicine and Health, University of Manchester, Manchester Academic Health Science Centre, Manchester, United Kingdom;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jon I.","family":"Williams","sequence":"additional","affiliation":[{"name":"Bausch Health Companies, Irvine, California;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sherif A.","family":"Shaarawy","sequence":"additional","affiliation":[{"name":"Manchester Academic Health Science Centre, Manchester Royal Eye Hospital, Manchester University NHS Foundation Trust, Manchester, United Kingdom;"},{"name":"Manchester Vision Regeneration Lab, Manchester Academic Health Science Centre, Manchester University NHS Foundation Trust, Manchester, United Kingdom;"},{"name":"Alexandria University, Alexandria, Egypt;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Amar","family":"Agarwal","sequence":"additional","affiliation":[{"name":"Dr Agarwal's Eye Hospital and Eye Research Centre, Chennai, India;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Anusha","family":"Venkataraman","sequence":"additional","affiliation":[{"name":"Dr Agarwal's Eye Hospital and Eye Research Centre, Chennai, India;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dhivya A.","family":"Kumar","sequence":"additional","affiliation":[{"name":"Dr Agarwal's Eye Hospital and Eye Research Centre, Chennai, India;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Timothy T.","family":"You","sequence":"additional","affiliation":[{"name":"Orange County Retina Medical Group, Laguna Hills, California; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Richard S.","family":"Hope","sequence":"additional","affiliation":[{"name":"Bausch & Lomb, Inc, Irvine, California."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20230816","doi-asserted-by":"crossref","first-page":"1226","DOI":"10.1136\/bjo.2009.166637","article-title":"Novel method to quantify traction in a vitrectomy procedure","volume":"94","author":"Teixeira","year":"2010","journal-title":"Br J Ophthalmol"},{"key":"R2-20230816","doi-asserted-by":"crossref","first-page":"e0178462","DOI":"10.1371\/journal.pone.0178462","article-title":"Performance analysis of a new hypersonic vitrector system","volume":"12","author":"Stanga","year":"2017","journal-title":"PLoS One"},{"key":"R3-20230816","first-page":"45","article-title":"The Girard ultrasonic fragmentor","volume":"37","author":"Girard","year":"1978","journal-title":"Adv Ophthalmol"},{"key":"R4-20230816","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1007\/s00417-007-0672-8","article-title":"Performance analysis of new-generation vitreous cutters","volume":"246","author":"Fang","year":"2008","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"R6-20230816","doi-asserted-by":"crossref","first-page":"e0173883","DOI":"10.1371\/journal.pone.0173883","article-title":"Ultrastructural and histopathologic findings after pars plana vitrectomy with a new hypersonic vitrector system. Qualitative preliminary assessment","volume":"12","author":"Pastor-Idoate","year":"2017","journal-title":"PLoS One"},{"key":"R7-20230816","first-page":"813","article-title":"Vitrectomy: a pars plana approach","volume":"75","author":"Machemer","year":"1971","journal-title":"Trans Am Acad Ophthalmol Otolaryngol"},{"key":"R8-20230816","doi-asserted-by":"crossref","first-page":"749","DOI":"10.1097\/IAE.0b013e3181631907","article-title":"Analyses of cutting and aspirating properties of vitreous cutters with high-speed camera","volume":"28","author":"Sato","year":"2008","journal-title":"Retina"},{"key":"R9-20230816","doi-asserted-by":"crossref","first-page":"1387","DOI":"10.1016\/j.ophtha.2009.11.004","article-title":"Vitreoretinal traction created by conventional cutters during vitrectomy","volume":"117","author":"Teixeira","year":"2010","journal-title":"Ophthalmology"},{"key":"R10-20230816","doi-asserted-by":"crossref","first-page":"162","DOI":"10.1016\/j.survophthal.2010.08.003","article-title":"Advantages and limitations of small gauge vitrectomy","volume":"56","author":"Thompson","year":"2011","journal-title":"Surv Ophthalmol"},{"key":"R11-20230816","doi-asserted-by":"crossref","first-page":"933","DOI":"10.1097\/IAE.0b013e3182733f38","article-title":"Analysis of a 23-gauge ultra high-speed cutter with duty cycle control","volume":"33","author":"Diniz","year":"2013","journal-title":"Retina"},{"key":"R12-20230816","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1097\/IAE.0b013e31815ec2b3","article-title":"20-, 23-, and 25-gauge vitreous cutters: performance and characteristics evaluation","volume":"28","author":"Hubschman","year":"2008","journal-title":"Retina"},{"key":"R13-20230816","doi-asserted-by":"crossref","first-page":"1761","DOI":"10.1097\/IAE.0b013e3182456f4d","article-title":"Tissue attraction associated with 20-gauge, 23-gauge, and enhanced 25-gauge dual-pneumatic vitrectomy probes","volume":"32","author":"Dugel","year":"2012","journal-title":"Retina"},{"key":"R14-20230816","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1159\/000343073","article-title":"Fluidics in a dual pneumatic ultra high-speed vitreous cutter system","volume":"229","author":"Diniz","year":"2013","journal-title":"Ophthalmologica"},{"key":"R15-20230816","doi-asserted-by":"crossref","first-page":"457","DOI":"10.1097\/00006982-199414050-00012","article-title":"The protective properties of liquid perfluorocarbons in phacofragmentation of dislocated lenses","volume":"14","author":"Movshovich","year":"1994","journal-title":"Retina"},{"key":"R16-20230816","doi-asserted-by":"crossref","first-page":"486","DOI":"10.1136\/bjo.79.5.486","article-title":"Pars plana incisions of four patients: histopathology and electron microscopy","volume":"79","author":"Koch","year":"1995","journal-title":"Br J Ophthalmol"}],"container-title":["Retina"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/IAE.0000000000002365","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,17]],"date-time":"2023-08-17T00:25:10Z","timestamp":1692231910000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/IAE.0000000000002365"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,1]]},"references-count":15,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.1097\/iae.0000000000002365","relation":{},"ISSN":["0275-004X"],"issn-type":[{"value":"0275-004X","type":"print"}],"subject":[],"published":{"date-parts":[[2020,1]]}}}