{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,30]],"date-time":"2026-04-30T00:20:42Z","timestamp":1777508442847,"version":"3.51.4"},"reference-count":17,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"10","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2020,10]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>To analyze swept-source optical coherence angiography slab images acquired at the default level for the choriocapillaris from the Zeiss PLEX Elite 9000 before and after using a previously described imaging compensation technique.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>Eyes of normal subjects, in their 20 seconds and 30 seconds, were evaluated. Angiographic slab images, 20 <jats:italic toggle=\"yes\">\u00b5<\/jats:italic>m in thickness, were taken at the default location of 29 to 49 <jats:italic toggle=\"yes\">\u00b5<\/jats:italic>m below the retinal pigment epithelium. These images were evaluated, as were images that underwent a published compensation technique that adjusts for light penetration to the sampled layer. Each set of images was threshold at 1 SD below the mean. Visual comparison of the swept-source optical coherence angiography images along with a quantitative analysis using a novel parameter known as multiscale structural similarity index, a measure of image similarity, was performed.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>Eleven eyes of 11 subjects were evaluated. The default location, 29 <jats:italic toggle=\"yes\">\u00b5<\/jats:italic>m to 49 <jats:italic toggle=\"yes\">\u00b5<\/jats:italic>m below the retinal pigment epithelium, showed the granular choriocapillaris appearance. Visual comparison showed that the compensation technique altered the appearance of the thresholded images, creating the appearance of new deficits while causing others to disappear. The mean multiscale structural similarity index for the original versus thresholded images and original versus thresholded compensated was 0.49 and 0.34, respectively, representing a statistically significant difference.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion:<\/jats:title>\n            <jats:p>The findings of this study show that the use of a commonly used imaging compensation technique can have undesired effects on the image, and its use should be carefully considered. A model explaining the cause of such changes in the choriocapillaris swept-source optical coherence angiography images is presented.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/iae.0000000000002866","type":"journal-article","created":{"date-parts":[[2020,5,26]],"date-time":"2020-05-26T04:13:03Z","timestamp":1590466383000},"page":"1865-1872","source":"Crossref","is-referenced-by-count":21,"title":["SWEPT-SOURCE OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY IMAGE COMPENSATION OF THE CHORIOCAPILLARIS INDUCES ARTIFACTS"],"prefix":"10.1097","volume":"40","author":[{"given":"Gerardo","family":"Ledesma-Gil","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pedro","family":"Fernandez-Avellaneda","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Richard F.","family":"Spaide","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2020,5,18]]},"reference":[{"key":"R1-20230817","doi-asserted-by":"crossref","first-page":"132","DOI":"10.1007\/s004170050053","article-title":"Morphological changes of choriocapillaris in experimentally induced chick myopia","volume":"236","author":"Hirata","year":"1998","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"R2-20230817","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1007\/BF00416864","article-title":"The choriocapillaris","volume":"192","author":"Hayreh","year":"1974","journal-title":"Albrecht Von Graefes Arch Klin Exp Ophthalmol"},{"key":"R3-20230817","doi-asserted-by":"crossref","first-page":"1606","DOI":"10.1167\/iovs.10-6476","article-title":"Choriocapillaris vascular dropout related to density of drusen in human eyes with early age-related macular degeneration","volume":"52","author":"Mullins","year":"2011","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R4-20230817","doi-asserted-by":"crossref","first-page":"265","DOI":"10.1097\/IAE.0b013e31827e25e0","article-title":"Subretinal drusenoid deposits in non-neovascular age-related macular degeneration: morphology, prevalence, topography, and biogenesis model","volume":"33","author":"Curcio","year":"2013","journal-title":"Retina"},{"key":"R5-20230817","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.preteyeres.2017.11.003","article-title":"Optical coherence tomography angiography","volume":"64","author":"Spaide","year":"2018","journal-title":"Prog Retin Eye Res"},{"key":"R6-20230817","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1016\/j.ajo.2016.07.023","article-title":"Choriocapillaris flow features follow a power law distribution: implications for characterization and mechanisms of disease progression","volume":"170","author":"Spaide","year":"2016","journal-title":"Am J Ophthalmol"},{"key":"R7-20230817","doi-asserted-by":"crossref","first-page":"2163","DOI":"10.1097\/IAE.0000000000000765","article-title":"Image artifacts in optical coherence tomography angiography","volume":"35","author":"Spaide","year":"2015","journal-title":"Retina"},{"key":"R8-20230817","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1167\/iovs.17-22953","article-title":"A novel strategy for quantifying choriocapillaris flow voids using swept-source oct angiography","volume":"59","author":"Zhang","year":"2018","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R10-20230817","doi-asserted-by":"crossref","first-page":"911","DOI":"10.1136\/bjophthalmol-2018-312643","article-title":"Choriocapillaris impairment around the atrophic lesions in patients with geographic atrophy: a swept-source optical coherence tomography angiography study","volume":"103","author":"Nassisi","year":"2019","journal-title":"Br J Ophthalmol"},{"key":"R11-20230817","doi-asserted-by":"crossref","first-page":"e0212563","DOI":"10.1371\/journal.pone.0212563","article-title":"Choriocapillaris flow impairment surrounding geographic atrophy correlates with disease progression","volume":"14","author":"Nassisi","year":"2019","journal-title":"PLoS One"},{"key":"R12-20230817","doi-asserted-by":"crossref","first-page":"658","DOI":"10.21037\/qims.2018.08.10","article-title":"Accurate estimation of choriocapillaris flow deficits beyond normal intercapillary spacing with swept source OCT angiography","volume":"8","author":"Zhang","year":"2018","journal-title":"Quant Imaging Med Surg"},{"key":"R13-20230817","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1016\/j.ajo.2019.09.017","article-title":"Correlations between different choriocapillaris flow deficit parameters in normal eyes using swept source OCT angiography","volume":"209","author":"Shi","year":"2020","journal-title":"Am J Ophthalmol"},{"key":"R14-20230817","doi-asserted-by":"crossref","first-page":"478","DOI":"10.1016\/j.oret.2019.01.024","article-title":"Correlations between choriocapillaris flow deficits around geographic atrophy and enlargement rates based on swept-source OCT imaging","volume":"3","author":"Thulliez","year":"2019","journal-title":"Ophthalmol Retina"},{"key":"R15-20230817","doi-asserted-by":"crossref","first-page":"34","DOI":"10.1016\/j.ajo.2018.08.014","article-title":"Topographic analysis of the choriocapillaris in intermediate age-related macular degeneration","volume":"196","author":"Borrelli","year":"2018","journal-title":"Am J Ophthalmol"},{"key":"R16-20230817","doi-asserted-by":"crossref","first-page":"110","DOI":"10.1016\/j.ajo.2018.12.025","article-title":"Age-dependent changes in the macular choriocapillaris of normal eyes imaged with swept-source optical coherence tomography angiography","volume":"200","author":"Zheng","year":"2019","journal-title":"Am J Ophthalmol"},{"key":"R17-20230817","doi-asserted-by":"crossref","first-page":"600","DOI":"10.1109\/TIP.2003.819861","article-title":"Image quality assessment: from error visibility to structural similarity","volume":"13","author":"Wang","year":"2004","journal-title":"IEEE Trans Image Process"},{"key":"R19-20230817","doi-asserted-by":"crossref","first-page":"035501","DOI":"10.1117\/1.JMI.4.3.035501","article-title":"Structural similarity index family for image quality assessment in radiological images","volume":"4","author":"Renieblas","year":"2017","journal-title":"J Med Imaging (Bellingham)"}],"container-title":["Retina"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/IAE.0000000000002866","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,17]],"date-time":"2023-08-17T01:11:57Z","timestamp":1692234717000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/IAE.0000000000002866"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,5,18]]},"references-count":17,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.1097\/iae.0000000000002866","relation":{},"ISSN":["0275-004X"],"issn-type":[{"value":"0275-004X","type":"print"}],"subject":[],"published":{"date-parts":[[2020,5,18]]}}}