{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,7]],"date-time":"2026-02-07T10:22:30Z","timestamp":1770459750259,"version":"3.49.0"},"reference-count":15,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2023,5]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>To evaluate a novel surgical technique for transscleral fixation of the intraocular lens (IOL) with four hollow haptics using 8-0 polypropylene suture looping and overhand knot.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>An 8-0 polypropylene suture was tied to a 10-0 polypropylene suture with an overhand knot. One set of 8-0 polypropylene suture was then passed through the IOL four haptics. The suture knot was buried by rotating into the sclera tunnel. Best-corrected visual acuity, intraocular pressure, and complications were determined.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>The IOLs were fixed with using an 8-0 polypropylene suture in 13 eyes of 11 patients with aphakia and dislocated crystalline lens. The mean preoperative corrected distance visual acuity was 0.71 \u00b1 0.58 logarithm of the minimum angle of resolution (Snellen 20\/103), and it improved to 0.24 \u00b1 0.25 logarithm of the minimum angle of resolution (Snellen 20\/35) at the final follow-up (<jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.05). No vitreous hemorrhage, hypotony, suture exposed, and pupillary capture of the IOL were observed in any of the patients.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion:<\/jats:title>\n            <jats:p>The authors have developed a new technique for transscleral IOL fixation with one set of an 8-0 polypropylene suture tied to a 10-0 polypropylene suture with an overhand knot. The overhand knot offers the opportunity to use an 8-0 polypropylene suture for the long-term safety and may not require the surgeon to learn any new technique.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/iae.0000000000002873","type":"journal-article","created":{"date-parts":[[2020,6,30]],"date-time":"2020-06-30T20:51:13Z","timestamp":1593550273000},"page":"860-863","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":8,"title":["8-0 Polypropylene Suture Looping and Overhand Knot: Transconjunctival Approach to Four-Point Scleral Fixation of an Akreos Adapt Intraocular Lens"],"prefix":"10.1097","volume":"43","author":[{"given":"Shijiu","family":"Chen","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gongqiang","family":"Yuan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wenhua","family":"Zhu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tianhui","family":"Shan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chunli","family":"Liu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jingjing","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2020,6,26]]},"reference":[{"key":"R1-20250605","doi-asserted-by":"crossref","first-page":"854","DOI":"10.1016\/j.jcrs.2003.09.050","article-title":"Transscleral fixation of foldable intraocular lenses","volume":"30","author":"Kaynak","year":"2004","journal-title":"J Cataract Refract Surg"},{"key":"R2-20250605","doi-asserted-by":"crossref","first-page":"1602","DOI":"10.1097\/IAE.0000000000001147","article-title":"Combined 27-gauge pars plana vitrectomy and scleral fixation of an Akreos AO60 intraocular lens using gore-tex suture","volume":"36","author":"Khan","year":"2016","journal-title":"Retina"},{"key":"R3-20250605","doi-asserted-by":"crossref","first-page":"991","DOI":"10.1016\/j.jcrs.2009.12.043","article-title":"Four-point suture scleral fixation of a hydrophilic acrylic IOL in aphakic eyes with insufficient capsule support","volume":"36","author":"Fass","year":"2010","journal-title":"J Cataract Refract Surg"},{"issue":"Suppl 1","key":"R4-20250605","doi-asserted-by":"crossref","first-page":"S24","DOI":"10.1097\/IAE.0000000000002207","article-title":"Adjustable buckle-slide suture: a novel surgical technique for transscleral fixation of intraocular lenses","volume":"39","author":"Zhao","year":"2019","journal-title":"Retina"},{"key":"R5-20250605","doi-asserted-by":"crossref","first-page":"1804","DOI":"10.1016\/j.jcrs.2015.09.005","article-title":"Transscleral fixation of a foldable posterior chamber intraocular lens","volume":"41","author":"Wallmann","year":"2015","journal-title":"J Cataract Refract Surg"},{"key":"R6-20250605","article-title":"Closed continuous-loop suture: a novel surgical technique for transscleral fixation of intraocular lenses","author":"Zhang","year":"2019","journal-title":"Retina"},{"key":"R7-20250605","doi-asserted-by":"crossref","first-page":"308","DOI":"10.1016\/j.ajo.2005.09.012","article-title":"Long-term outcome of combined pars plana vitrectomy and scleral fixated sutured posterior chamber intraocular lens implantation","volume":"141","author":"Vote","year":"2006","journal-title":"Am J Ophthalmol"},{"key":"R8-20250605","doi-asserted-by":"crossref","first-page":"1421","DOI":"10.1016\/j.jcrs.2018.08.008","article-title":"New use of 8-0 polypropylene suture for four-point scleral fixation of secondary intraocular lenses","volume":"44","author":"John","year":"2018","journal-title":"J Cataract Refract Surg"},{"issue":"suppl 1","key":"R9-20250605","doi-asserted-by":"crossref","first-page":"S62","DOI":"10.1097\/IAE.0000000000002291","article-title":"Intraocular suture looping and overhand friction knot: a flapless technique to refixate dislocated intraocular lenses","volume":"39","author":"Zhang","year":"2019","journal-title":"Retina"},{"key":"R10-20250605","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1007\/BF00159844","article-title":"Lens guide suture for transport and fixation in secondary IOL implantation after intracapsular extraction","volume":"9","author":"Malbran","year":"1986","journal-title":"Int Ophthalmol"},{"key":"R11-20250605","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1016\/j.ophtha.2007.02.018","article-title":"Long-term results of scleral fixation of posterior chamber intraocular lenses in children","volume":"115","author":"Asadi","year":"2008","journal-title":"Ophthalmology"},{"key":"R12-20250605","doi-asserted-by":"crossref","first-page":"1320","DOI":"10.1016\/j.jcrs.2004.12.060","article-title":"Late dislocation of scleral-sutured posterior chamber intraocular lenses","volume":"31","author":"Price","year":"2005","journal-title":"J Cataract Refract Surg"},{"key":"R13-20250605","doi-asserted-by":"crossref","first-page":"609","DOI":"10.1016\/j.jcrs.2013.09.014","article-title":"Outcomes of scleral-sutured conventional and aniridia intraocular lens implantation performed in a university hospital setting","volume":"40","author":"Lockington","year":"2014","journal-title":"J Cataract Refract Surg"},{"key":"R14-20250605","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1016\/S0886-3350(00)00638-6","article-title":"Tilt and decentration after primary and secondary transsclerally sutured posterior chamber intraocular lens implantation","volume":"27","author":"Durak","year":"2001","journal-title":"J Cataract Refract Surg"},{"key":"R15-20250605","doi-asserted-by":"crossref","first-page":"1003","DOI":"10.1097\/IAE.0000000000001333","article-title":"Transconjunctival approach to scleral fixation of posterior chamber intraocular lenses using gore-tex suture","volume":"37","author":"Cutler","year":"2017","journal-title":"Retina"}],"container-title":["Retina"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/IAE.0000000000002873","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,5]],"date-time":"2025-06-05T17:08:24Z","timestamp":1749143304000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/IAE.0000000000002873"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,6,26]]},"references-count":15,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.1097\/iae.0000000000002873","relation":{},"ISSN":["0275-004X"],"issn-type":[{"value":"0275-004X","type":"print"}],"subject":[],"published":{"date-parts":[[2020,6,26]]}}}