{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,25]],"date-time":"2026-04-25T10:59:41Z","timestamp":1777114781717,"version":"3.51.4"},"reference-count":16,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2021,5]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>To compare the visual outcomes and complication rates of sutureless cannula-based intraocular lens scleral (SCILS) fixation performed with 25-gauge (25 G) versus 27-gauge (27 G) instrumentation.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>A retrospective chart review of consecutive cases of eyes without capsular support that underwent SCILS fixation of a three-piece intraocular lens. Sutureless cannula-based intraocular lens scleral fixation was performed by transconjunctival use of either 25-G or 27-G trocar cannulas. During postoperative follow-up evaluations, visual acuity and intraocular pressure were measured, and slit-lamp and indirect ophthalmoscopy examinations were performed to assess for development of known complications.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>A total of 69 eyes underwent 25 G (27 eyes) or 27 G (42 eyes) SCILS fixation. The mean preoperative logarithm of the minimum angle of resolution visual acuity trended toward improvement from 0.95 \u00b1 0.68 (20\/178 Snellen equivalent) to 0.67 \u00b1 0.64 (20\/94 Snellen equivalent) for 25 G group at 1 year. Similar trend toward visual acuity improvement was seen in 27 G group with a mean preoperative logarithm of the minimum angle of resolution visual acuity of 1.43 \u00b1 0.94 (20\/538 Snellen equivalent) improving to 0.86 \u00b1 1.00 (20\/145 Snellen equivalent) at 1 year. Statistically significant improvement was seen as early as postoperative week one for 27 G group (<jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.01), whereas statistically significant worsening was noted at the same time in 25 G group (<jats:italic toggle=\"yes\">P<\/jats:italic> = 0.01). There was a statistically significant reduction in intraocular lens displacement (<jats:italic toggle=\"yes\">P<\/jats:italic> = 0.01) and need for reoperation (<jats:italic toggle=\"yes\">P<\/jats:italic> = 0.01) in 27 G group.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion:<\/jats:title>\n            <jats:p>Compared with 25 G SCILS fixation, eyes managed with 27 G SCILS fixation experienced more rapid visual acuity improvement. In addition, there was a lower rate of complications including intraocular lens displacement and need for reoperation.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/iae.0000000000002991","type":"journal-article","created":{"date-parts":[[2020,10,2]],"date-time":"2020-10-02T21:12:31Z","timestamp":1601673151000},"page":"940-946","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":3,"title":["COMPARISON OF 25- AND 27-GAUGE SUTURELESS CANNULA-BASED INTRAOCULAR LENS SCLERAL FIXATION VISUAL ACUITY OUTCOMES AND COMPLICATION RATES"],"prefix":"10.1097","volume":"41","author":[{"given":"Ankit B.","family":"Kadakia","sequence":"first","affiliation":[{"name":"University of Missouri\u2014Kansas City School of Medicine, Kansas City, Missouri;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tien P.","family":"Wong","sequence":"additional","affiliation":[{"name":"Blanton Eye Institute, Houston Methodist Hospital, Houston, Texas;"},{"name":"Retina Consultants of Houston, Houston, Texas; and"},{"name":"Retina Consultants of America, Dallas, Texas."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Charlie C.","family":"Wykoff","sequence":"additional","affiliation":[{"name":"Blanton Eye Institute, Houston Methodist Hospital, Houston, Texas;"},{"name":"Retina Consultants of Houston, Houston, Texas; and"},{"name":"Retina Consultants of America, Dallas, Texas."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ankoor R.","family":"Shah","sequence":"additional","affiliation":[{"name":"Blanton Eye Institute, Houston Methodist Hospital, Houston, Texas;"},{"name":"Retina Consultants of Houston, Houston, Texas; and"},{"name":"Retina Consultants of America, Dallas, Texas."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20250607","first-page":"58","article-title":"The evolution of cataract surgery","volume":"113","author":"Davis","year":"2016","journal-title":"Mo Med"},{"key":"R2-20250607","doi-asserted-by":"crossref","first-page":"600","DOI":"10.1016\/S0140-6736(17)30544-5","article-title":"Cataracts","volume":"390","author":"Liu","year":"2017","journal-title":"Lancet"},{"key":"R3-20250607","doi-asserted-by":"crossref","first-page":"80","DOI":"10.3341\/kjo.2000.14.2.80","article-title":"Management of posteriorly dislocated intraocular lens using pars plana vitrectomy","volume":"14","author":"Seo","year":"2000","journal-title":"Korean J Ophthalmol"},{"key":"R4-20250607","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/s00417-014-2834-9","article-title":"Sutureless scleral fixation of intraocular lenses: outcomes of two approaches. The 2014 yasuo tano memorial lecture","volume":"253","author":"Abbey","year":"2015","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"R5-20250607","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1177\/2474126417690650","article-title":"Scleral-fixated intraocular lenses: past and present","volume":"1","author":"Stem","year":"2017","journal-title":"J Vitreoretin Dis"},{"key":"R6-20250607","doi-asserted-by":"crossref","first-page":"1450","DOI":"10.4103\/ijo.IJO_659_17","article-title":"Sutureless 27-gauge needle-assisted transconjunctival intrascleral intraocular lens fixation: initial experience","volume":"65","author":"Kelkar","year":"2017","journal-title":"Indian J Ophthalmol"},{"key":"R7-20250607","doi-asserted-by":"crossref","first-page":"1263","DOI":"10.1016\/j.jcrs.2011.02.023","article-title":"Visual outcomes and complications of scleral-fixated posterior chamber intraocular lenses","volume":"37","author":"McAllister","year":"2011","journal-title":"J Cataract Refractive Surg"},{"key":"R8-20250607","doi-asserted-by":"crossref","first-page":"657","DOI":"10.1097\/IAE.0b013e31827b6499","article-title":"Transconjunctival sutureless haptic fixation of posterior chamber IOL: a minimally traumatic approach for IOL rescue or secondary implantation","volume":"33","author":"Prasad","year":"2013","journal-title":"Retina"},{"key":"R9-20250607","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1016\/j.jcrs.2015.09.019","article-title":"Comparison of sutured versus sutureless scleral-fixated intraocular lenses","volume":"42","author":"Sindal","year":"2016","journal-title":"J Cataract Refract Surg"},{"key":"R10-20250607","doi-asserted-by":"crossref","first-page":"64","DOI":"10.4103\/ijo.IJO_447_18","article-title":"Novel technique of sutureless glueless scleral fixated intraocular lens (SFIOL)","volume":"67","author":"Walia","year":"2019","journal-title":"Indian J Ophthalmol"},{"key":"R11-20250607","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1016\/j.ophtha.2013.08.043","article-title":"Sutureless 27-gauge needle-guided intrascleral intraocular lens implantation with lamellar scleral dissection","volume":"121","author":"Yamane","year":"2014","journal-title":"Ophthalmology"},{"key":"R12-20250607","doi-asserted-by":"crossref","first-page":"224","DOI":"10.1111\/aos.14307","article-title":"Sutureless intrascleral fixation using different three-piece posterior chamber intraocular lenses: a literature review of surgical techniques in cases of insufficient capsular support and a retrospective multicentre study","volume":"98","author":"Czajka","year":"2020","journal-title":"Acta Ophthalmol"},{"key":"R13-20250607","doi-asserted-by":"crossref","first-page":"376","DOI":"10.3928\/23258160-20160324-14","article-title":"Sutureless intrascleral fixation of secondary intraocular lens using 27-gauge vitrectomy system","volume":"47","author":"Todorich","year":"2016","journal-title":"Ophthalmic Surg Lasers Imaging Retina"},{"key":"R14-20250607","doi-asserted-by":"crossref","first-page":"2149","DOI":"10.1097\/IAE.0000000000002268","article-title":"27-gauge sutureless intrascleral fixation of intraocular lenses with haptic flanging: short-term clinical outcomes and a disinsertion force study","volume":"39","author":"Stem","year":"2019","journal-title":"Retina"},{"key":"R15-20250607","doi-asserted-by":"crossref","first-page":"388","DOI":"10.3928\/1081-597X-19970701-16","article-title":"Proper method for calculating average visual acuity","volume":"13","author":"Holladay","year":"1997","journal-title":"J Refract Surg"},{"key":"R16-20250607","doi-asserted-by":"crossref","first-page":"1151","DOI":"10.1007\/s00592-020-01530-8","article-title":"Results in comparison between 30 gauge ultrathin wall and 27 gauge needle in sutureless intraocular lens flanged technique in diabetic patients: 24-month follow-up study","volume":"57","author":"Iglicki","year":"2020","journal-title":"Acta Diabetol"}],"container-title":["Retina"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/IAE.0000000000002991","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,7]],"date-time":"2025-06-07T18:06:55Z","timestamp":1749319615000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/IAE.0000000000002991"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,5]]},"references-count":16,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.1097\/iae.0000000000002991","relation":{},"ISSN":["0275-004X"],"issn-type":[{"value":"0275-004X","type":"print"}],"subject":[],"published":{"date-parts":[[2021,5]]}}}