{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,10]],"date-time":"2026-06-10T20:13:13Z","timestamp":1781122393824,"version":"3.54.1"},"reference-count":10,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"6","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2022,6]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>To evaluate the utility of extending the limbus-to-cannula distance to 6.0 mm during pars plana vitrectomy for highly myopic eyes.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>Four eyes with axial lengths exceeding 31.0 mm, that underwent 25-gauge pars plana vitrectomy were retrospectively evaluated. Assuming that cannulas were inserted 3.5 mm and 6.0 mm from the corneal limbus, the distance from the cannula to the fovea (CF distance) was preoperatively evaluated using anterior segmental optical coherence tomography. Surgical complications were also investigated.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>The CF distance was shortened by 1.22 \u00b1 0.05 mm and 1.22 \u00b1 0.09 mm on the temporal and nasal sides, respectively, by inserting the cannula at 3.5 mm to 6.0 mm from the corneal limbus. As per the preoperatively measured CF distance, one of the cannulas was inserted 6.0 mm from the corneal limbus in three eyes. Their cannulas were confirmed to be inserted at the pars plana, and no surgical complications associated with this technique were observed.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion:<\/jats:title>\n            <jats:p>Extending the limbus-to-cannula distance to 6.0 mm during pars plana vitrectomy could be one of the options to reach the posterior pole in highly myopic eyes. A preoperatively measured CF distance can be a clinical criterion in determining the cannula position.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/iae.0000000000003025","type":"journal-article","created":{"date-parts":[[2020,12,10]],"date-time":"2020-12-10T20:19:39Z","timestamp":1607631579000},"page":"1199-1202","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":12,"title":["Extending the Limbus-to-Cannula Distance to 6.0 mm During Pars Plana Vitrectomy in Highly Myopic Eyes"],"prefix":"10.1097","volume":"42","author":[{"given":"Yasuaki","family":"Iwama","sequence":"first","affiliation":[{"name":"Department of Ophthalmology, Osaka Rosai Hospital Clinical Research Center for Optical Sensory Organ Disability, Osaka, Japan; and"},{"name":"Department of Ophthalmology, Osaka University Graduate School of Medicine, Osaka, Japan."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Toshihide","family":"Ikeda","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Osaka Rosai Hospital Clinical Research Center for Optical Sensory Organ Disability, Osaka, Japan; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiroshi","family":"Nakashima","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Osaka Rosai Hospital Clinical Research Center for Optical Sensory Organ Disability, Osaka, Japan; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eri","family":"Matsumoto","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Osaka Rosai Hospital Clinical Research Center for Optical Sensory Organ Disability, Osaka, Japan; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ryo","family":"Inoue","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Osaka Rosai Hospital Clinical Research Center for Optical Sensory Organ Disability, Osaka, Japan; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kazuyuki","family":"Emi","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Osaka Rosai Hospital Clinical Research Center for Optical Sensory Organ Disability, Osaka, Japan; and"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20250607","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1186\/s40942-017-0090-y","article-title":"Vitrectomy in high myopia: a narrative review","volume":"3","author":"Coppola","year":"2017","journal-title":"Int J Retina Vitreous"},{"key":"R2-20250607","doi-asserted-by":"crossref","first-page":"437","DOI":"10.3928\/15428877-20070901-17","article-title":"Limitation of 25-gauge vitrectomy instrumentation in highly myopic eyes","volume":"38","author":"Singh","year":"2007","journal-title":"Ophthalmic Surg Lasers Imaging"},{"key":"R3-20250607","doi-asserted-by":"crossref","first-page":"1475","DOI":"10.1097\/IAE.0b013e318297f85b","article-title":"Long-shaft forceps for membrane peeling in highly myopic eyes","volume":"33","author":"Gao","year":"2013","journal-title":"Retina"},{"key":"R4-20250607","doi-asserted-by":"crossref","first-page":"2660","DOI":"10.1097\/IAE.0000000000000883","article-title":"Modified curved aspiration cannulas and end-gripping forceps for 25-gauge vitrectomy on highly myopic eyes","volume":"35","author":"Lytvynchuk","year":"2015","journal-title":"Retina"},{"key":"R5-20250607","doi-asserted-by":"crossref","first-page":"888","DOI":"10.1016\/j.oret.2018.01.009","article-title":"Influence of surgical procedures and instruments on the incidence of suprachoroidal hemorrhage during 25-gauge pars plana vitrectomy","volume":"2","author":"Iwama","year":"2018","journal-title":"Ophthalmol Retina"},{"key":"R6-20250607","doi-asserted-by":"crossref","first-page":"802","DOI":"10.1001\/archopht.1992.01080180074031","article-title":"Postnatal development of the ciliary body and pars plana. A morphometric study in childhood","volume":"110","author":"Aiello","year":"1992","journal-title":"Arch Ophthalmol"},{"key":"R7-20250607","doi-asserted-by":"crossref","first-page":"208","DOI":"10.1097\/00006982-200502000-00015","article-title":"Transconjunctival sutureless 23-gauge vitrectomy","volume":"25","author":"Eckardt","year":"2005","journal-title":"Retina"},{"key":"R8-20250607","doi-asserted-by":"crossref","first-page":"198","DOI":"10.1016\/j.ophtha.2011.09.002","article-title":"Pars plana width and sclerotomy sites","volume":"119","author":"Sudhalkar","year":"2012","journal-title":"Ophthalmology"},{"key":"R9-20250607","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1097\/00006982-199703000-00009","article-title":"Morphometric analysis of pars plana development in humans","volume":"17","author":"Hairston","year":"1997","journal-title":"Retina"},{"key":"R10-20250607","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1016\/j.ajo.2017.12.015","article-title":"Implantable collamer lens sizing method based on swept-source anterior segment optical coherence tomography","volume":"187","author":"Nakamura","year":"2018","journal-title":"Am J Ophthalmol"}],"container-title":["Retina"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/IAE.0000000000003025","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,7]],"date-time":"2025-06-07T18:02:47Z","timestamp":1749319367000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/IAE.0000000000003025"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,6]]},"references-count":10,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.1097\/iae.0000000000003025","relation":{},"ISSN":["0275-004X"],"issn-type":[{"value":"0275-004X","type":"print"}],"subject":[],"published":{"date-parts":[[2022,6]]}}}