{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,21]],"date-time":"2026-10-21T11:21:33Z","timestamp":1792581693956,"version":"4.5.0"},"reference-count":7,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2022,1]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>To introduce cases of intraocular lens (IOL) malposition after sutureless intrascleral fixation.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>We retrospectively analyzed the medical records of patients who underwent sutureless intrascleral fixation. Cases with postoperative IOL requiring reoperation were analyzed further.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>Of the 48 eyes that underwent sutureless intrascleral fixation of their IOL, seven eyes had postoperative IOL malposition and underwent reoperation (14.6%). There was no difference in the clinical results between the intravitreal (33 eyes) and intracameral (15 eyes) techniques, but IOL malposition requiring reoperation was more frequent in the latter (2 cases [6.1%] vs. 5 cases [33.3%], <jats:italic toggle=\"yes\">P<\/jats:italic> = 0.024). In the 7 eyes that required reoperation, the visual acuity before reoperation was 0.9 \u00b1 0.6 logMAR (20\/159), whereas astigmatism was \u22124.8 \u00b1 3.2 diopters. The visual acuity and cylindrical error improved to 0.1 \u00b1 0.2 logMAR (20\/25) and \u22122.4 \u00b1 2.3 diopters, respectively, at 6 months after the secondary operation.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion:<\/jats:title>\n            <jats:p>In 14.6% of the patients who underwent sutureless intrascleral fixation of the IOL, IOL malposition developed and reoperation was performed. With the intravitreal technique, which uses a wider space than the intracameral technique, the frequency of postoperative IOL malposition could be reduced.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/iae.0000000000003279","type":"journal-article","created":{"date-parts":[[2021,8,9]],"date-time":"2021-08-09T22:30:11Z","timestamp":1628548211000},"page":"64-72","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":8,"title":["INTRAOCULAR LENS MALPOSITION AFTER SUTURELESS INTRASCLERAL FIXATION OF INTRAOCULAR LENS"],"prefix":"10.1097","volume":"42","author":[{"given":"Zeeyoon","family":"Byun","sequence":"first","affiliation":[{"name":"Department of Ophthalmology, HanGil Eye Hospital, Incheon, Korea; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mingui","family":"Kong","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, HanGil Eye Hospital, Incheon, Korea; and"},{"name":"Department of Ophthalmology, College of Medicine, Catholic Kwandong University, Incheon, Korea."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gisung","family":"Son","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, HanGil Eye Hospital, Incheon, Korea; and"},{"name":"Department of Ophthalmology, College of Medicine, Catholic Kwandong University, Incheon, Korea."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20250607","doi-asserted-by":"crossref","first-page":"1289","DOI":"10.1016\/S0886-3350(97)80104-6","article-title":"Sutureless scleral fixation of intraocular lenses","volume":"23","author":"Maggi","year":"1997","journal-title":"J Cataract Refract Surg"},{"key":"R2-20250607","doi-asserted-by":"crossref","first-page":"210","DOI":"10.1097\/ICU.0000000000000474","article-title":"Sutureless transscleral fixation of secondary intraocular lenses","volume":"29","author":"Nudleman","year":"2018","journal-title":"Curr Opin Ophthalmol"},{"key":"R3-20250607","doi-asserted-by":"crossref","first-page":"488","DOI":"10.1080\/08820538.2019.1652761","article-title":"Outcomes of using sutureless, scleral-fixated posterior chamber intraocular lenses","volume":"34","author":"Kansal","year":"2019","journal-title":"Semin Ophthalmol"},{"key":"R4-20250607","doi-asserted-by":"crossref","first-page":"224","DOI":"10.1111\/aos.14307","article-title":"Sutureless intrascleral fixation using different three-piece posterior chamber intraocular lenses: a literature review of surgical techniques in cases of insufficient capsular support and a retrospective multicentre study","volume":"98","author":"Czajka","year":"2020","journal-title":"Acta Ophthalmol"},{"key":"R5-20250607","doi-asserted-by":"crossref","first-page":"e499","DOI":"10.1111\/aos.14313","article-title":"Flanged intraocular lens fixation via 27-gauge trocars using a double-needle technique decreases surgical wounds without losing its therapeutic effect","volume":"98","author":"Ishikawa","year":"2020","journal-title":"Acta Ophthalmol"},{"key":"R6-20250607","doi-asserted-by":"crossref","first-page":"761","DOI":"10.1097\/IAE.0000000000002952","article-title":"Comparison of scleral fixation of intraocular lens: sutureless intrascleral fixation versus conventional sutured scleral fixation","volume":"41","author":"Jang","year":"2021","journal-title":"Retina"},{"key":"R7-20250607","article-title":"Pound-shape silicone oil retention suture in aphakic eyes with intact iris","author":"Jun","year":"2020","journal-title":"Retina"}],"container-title":["Retina"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/IAE.0000000000003279","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,7]],"date-time":"2025-06-07T18:06:34Z","timestamp":1749319594000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/IAE.0000000000003279"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,1]]},"references-count":7,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.1097\/iae.0000000000003279","relation":{},"ISSN":["0275-004X"],"issn-type":[{"value":"0275-004X","type":"print"}],"subject":[],"published":{"date-parts":[[2022,1]]}}}