{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,6,5]],"date-time":"2025-06-05T17:40:05Z","timestamp":1749145205097,"version":"3.41.0"},"reference-count":14,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"12","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2023,12]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>To describe a flapless technique for two-point fixation of intraocular lens (IOL) with four fenestrated haptics.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>A transconjunctival puncture of 1-mL syringe needle was used to guide the suture needle out of the eye. The suture was taken out of the eye through the corneal incision, passed through the pair of fenestrated haptics of the IOL and then securely tied with overhand knots. The folded IOL was implanted into the posterior chamber. The anchor knots were created by both ends of the thread approximately 4 mm to 5 mm apart from the transconjunctival puncture and was intrasclerally buried.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>The technique was used in 18 eyes (18 patients). The mean postoperative follow-up period was 17.22 \u00b1 8.82 months. The IOLs of all the eyes remained well positioned and stable at the final follow-up. The visual acuities of all the eyes were improved postoperatively. No suture loosening, suture erosion, hypotony, scleral atrophy, chronic inflammation, retinal tears, and\/or detachments were observed in any of the patients.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion:<\/jats:title>\n            <jats:p>The present technique provides minimal trauma and reliable stability for the two-point transscleral fixation of four fenestrated haptics IOL.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/iae.0000000000003400","type":"journal-article","created":{"date-parts":[[2022,1,5]],"date-time":"2022-01-05T09:12:55Z","timestamp":1641373975000},"page":"2072-2074","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":2,"title":["Intraocular Suture Technique for Flapless Two-Point Fixation of Four Fenestrated Haptics Intraocular Lenses"],"prefix":"10.1097","volume":"43","author":[{"given":"Yingxu","family":"Zhang","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jinbiao","family":"Zheng","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jiahui","family":"Liu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20250605","doi-asserted-by":"crossref","first-page":"991","DOI":"10.1016\/j.jcrs.2009.12.043","article-title":"Four-point suture scleral fixation of a hydrophilic acrylic IOL in aphakic eyes with insufficient capsule support","volume":"36","author":"Fass","year":"2010","journal-title":"J Cataract Refract Surg"},{"key":"R2-20250605","doi-asserted-by":"crossref","first-page":"211","DOI":"10.1016\/j.jcrs.2015.10.068","article-title":"Small-incision 4-point scleral suture fixation of a foldable hydrophilic acrylic intraocular lens in the absence of capsule support","volume":"42","author":"Terveen","year":"2016","journal-title":"J Cataract Refract Surg"},{"key":"R3-20250605","doi-asserted-by":"crossref","first-page":"1605","DOI":"10.1097\/IAE.0000000000001148","article-title":"Twenty-seven-gauge vitrectomy-assisted four-point scleral fixation of intraocular lens in the absence of capsular support","volume":"36","author":"Wang","year":"2016","journal-title":"Retina"},{"key":"R4-20250605","doi-asserted-by":"crossref","first-page":"S21","DOI":"10.1097\/IAE.0000000000002138","article-title":"Minimally invasive ab interno four-point scleral fixation of intraocular lens","volume":"39","author":"Hadayer","year":"2019","journal-title":"Retina"},{"key":"R5-20250605","doi-asserted-by":"crossref","first-page":"1421","DOI":"10.1016\/j.jcrs.2018.08.008","article-title":"New use of 8-0 polypropylene suture for four-point scleral fixation of secondary intraocular lenses","volume":"44","author":"John","year":"2018","journal-title":"J Cataract Refract Surg"},{"key":"R6-20250605","doi-asserted-by":"crossref","first-page":"6642007","DOI":"10.1155\/2020\/6642007","article-title":"Intrascleral suture anchoring: a flapless\/grooveless four-point intraocular lens fixation technique","volume":"2020","author":"Hu","year":"2020","journal-title":"J Ophthalmol"},{"key":"R7-20250605","doi-asserted-by":"crossref","first-page":"1602","DOI":"10.1097\/IAE.0000000000001147","article-title":"Combined 27-gauge pars plana vitrectomy and scleral fixation of an Akreos AO60 intraocular lens using gore-tex suture","volume":"36","author":"Khan","year":"2016","journal-title":"Retina"},{"key":"R8-20250605","doi-asserted-by":"crossref","first-page":"S24","DOI":"10.1097\/IAE.0000000000002207","article-title":"Adjustable buckle-slide suture: a novel surgical technique for transscleral fixation of intraocular lenses","volume":"39","author":"Zhao","year":"2019","journal-title":"Retina"},{"key":"R9-20250605","doi-asserted-by":"crossref","first-page":"1804","DOI":"10.1016\/j.jcrs.2015.09.005","article-title":"Transscleral fixation of a foldable posterior chamber intraocular lens","volume":"41","author":"Wallmann","year":"2015","journal-title":"J Cataract Refract Surg"},{"key":"R10-20250605","doi-asserted-by":"crossref","first-page":"1136","DOI":"10.1016\/j.ophtha.2017.03.036","article-title":"Flanged intrascleral intraocular lens fixation with double-needle technique","volume":"124","author":"Yamane","year":"2017","journal-title":"Ophthalmology"},{"key":"R11-20250605","doi-asserted-by":"crossref","first-page":"317","DOI":"10.1016\/j.jcrs.2013.01.019","article-title":"Handshake technique for glued intrascleral haptic fixation of a posterior chamber intraocular lens","volume":"39","author":"Agarwal","year":"2013","journal-title":"J Cataract Refract Surg"},{"key":"R12-20250605","doi-asserted-by":"crossref","first-page":"1707","DOI":"10.1016\/j.jcrs.2016.10.008","article-title":"Iris fixation of posterior chamber intraocular lenses","volume":"42","author":"Yazdani-Abyaneh","year":"2016","journal-title":"J Cataract Refract Surg"},{"key":"R13-20250605","doi-asserted-by":"crossref","first-page":"167","DOI":"10.1136\/bjo.2009.162180","article-title":"Z-suture: a new knotless technique for transscleral suture fixation of intraocular implants","volume":"94","author":"Szurman","year":"2010","journal-title":"Br J Ophthalmol"},{"key":"R14-20250605","doi-asserted-by":"crossref","first-page":"497","DOI":"10.1016\/j.jcrs.2015.01.003","article-title":"Friction knot to fixate scleral sutures","volume":"41","author":"Oskala","year":"2015","journal-title":"J Cataract Refract Surg"}],"container-title":["Retina"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/IAE.0000000000003400","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,5]],"date-time":"2025-06-05T17:06:38Z","timestamp":1749143198000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/IAE.0000000000003400"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,12]]},"references-count":14,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.1097\/iae.0000000000003400","relation":{},"ISSN":["0275-004X"],"issn-type":[{"type":"print","value":"0275-004X"}],"subject":[],"published":{"date-parts":[[2023,12]]}}}