{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,6,5]],"date-time":"2025-06-05T17:40:04Z","timestamp":1749145204727,"version":"3.41.0"},"reference-count":15,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"12","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2023,12]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>To evaluate the efficiency and safety of using an intraocular foreign body forceps with two nitinol loops at its tip to capture and chop dropped nucleus (DN) during vitrectomy as an alternative method and to evaluate the outcomes and complications of this surgical technique.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>The eyes that underwent 23-gauge vitrectomy with removal of DN using nitinol forceps with a minimum follow-up time of 1 year are included in this study. The efficiency of surgical technique and anatomical and functional results with complications is recorded.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>Nine patients with a mean age of 73.11 \u00b1 2.15 years were included in this study. The mean time between DN and vitrectomy was 7.67 \u00b1 3.74 (5\u201314) days. In all eyes, DN was easily chopped and removed with aspiration. Argon laser photocoagulation was performed in 4 eyes (44.44%) during surgery. All eyes were followed up for a mean time of 21.11 \u00b1 12.36 (12\u201348) months. The mean preoperative best-corrected visual acuity increased significantly during the postoperative follow-up (<jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.001). No complications related to the cataract surgery or DN removal were observed.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion:<\/jats:title>\n            <jats:p>Surgical removal of DN with the help of these forceps with nitinol loops is found to be safe and effective in this study. This method avoids ultrasonographic energy and enables 23-gauge vitrectomy without a fragmatome.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/iae.0000000000003476","type":"journal-article","created":{"date-parts":[[2022,3,25]],"date-time":"2022-03-25T19:00:09Z","timestamp":1648234809000},"page":"2126-2129","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["INTRAVITREAL CHOPPING OF DROPPED NUCLEUS WITH A NITINOL INTRAOCULAR FOREIGN BODY FORCEPS: AN ALTERNATIVE TECHNIQUE FOR THE MANAGEMENT OF RETAINED NUCLEUS FRAGMENTS"],"prefix":"10.1097","volume":"43","author":[{"given":"Nur","family":"Acar","sequence":"first","affiliation":[{"name":"Ac\u0131badem M. A Ayd\u0131nlar University, School of Medicine, Maslak Hospital, Istanbul, Turkey; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pelin","family":"Celiker","sequence":"additional","affiliation":[{"name":"SUNY Downstate College of Medicine, New York, New York."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20250605","doi-asserted-by":"crossref","first-page":"493","DOI":"10.1136\/bjo.2007.114637","article-title":"Displacement of nuclear fragments into the vitreous complicating phacoemulsification surgery in the UK: clinical features, outcomes and management","volume":"92","author":"Von Lany","year":"2008","journal-title":"Br J Ophthalmol"},{"key":"R2-20250605","doi-asserted-by":"crossref","first-page":"287","DOI":"10.1097\/j.jcrs.0000000000000019","article-title":"Risk factors for dropped nucleus in cataract surgery as reflected by the European registry of quality outcomes for cataract and refractive surgery","volume":"46","author":"Lundstr\u00f6m","year":"2020","journal-title":"J Cataract Refract Surg"},{"key":"R3-20250605","first-page":"1","article-title":"Dropped nucleus during cataract surgery in south India: incidence, risk factors, and outcomes","volume":"12","author":"Engelhard","year":"2021","journal-title":"Ophthalmic Epidemiol"},{"key":"R4-20250605","doi-asserted-by":"crossref","first-page":"1749","DOI":"10.1097\/IAE.0b013e3182453309","article-title":"Hybrid 20\/23-gauge pars plana vitrectomy for retained lens fragments after cataract surgery","volume":"32","author":"Barthelmes","year":"2012","journal-title":"Retina"},{"key":"R5-20250605","doi-asserted-by":"crossref","first-page":"1697","DOI":"10.1016\/j.jcrs.2005.02.045","article-title":"Illuminated endochopper in the management of posteriorly dislocated lens nucleus","volume":"31","author":"Erakgun","year":"2005","journal-title":"J Cataract Refract Surg"},{"key":"R6-20250605","doi-asserted-by":"crossref","first-page":"401","DOI":"10.1016\/S0002-9394(14)76247-6","article-title":"Management of the dislocated crystalline lens with a perfluorocarbon liquid","volume":"112","author":"Shapiro","year":"1991","journal-title":"Am J Ophthalmol"},{"key":"R7-20250605","doi-asserted-by":"crossref","first-page":"334","DOI":"10.1016\/j.jcrs.2013.01.022","article-title":"Management of posteriorly dislocated crystalline lens with perfluorocarbon liquid and fibrin glue-assisted scleral-fixated intraocular lens implantation","volume":"39","author":"Lee","year":"2013","journal-title":"J Cataract Refract Surg"},{"key":"R8-20250605","doi-asserted-by":"crossref","first-page":"1429","DOI":"10.1136\/bjophthalmol-2013-304737","article-title":"Clinical outcomes of sleeveless phacotip assisted levitation of dropped nucleus","volume":"98","author":"Agarwal","year":"2014","journal-title":"Br J Ophthalmol"},{"key":"R9-20250605","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1038\/s41598-021-87022-3","article-title":"The kebab technique uses a bipolar pencil to retrieve a dropped nucleus of the lens via a small incision","volume":"11","author":"Aso","year":"2021","journal-title":"Sci Rep"},{"key":"R10-20250605","doi-asserted-by":"crossref","first-page":"584","DOI":"10.1097\/00006982-200308000-00034","article-title":"Foreign body snare for the removal of large non magnetic intravitreal foreign bodies and dislocated lens nuclei\/iols","volume":"23","author":"Murthy","year":"2003","journal-title":"Retina"},{"key":"R11-20250605","doi-asserted-by":"crossref","first-page":"2378","DOI":"10.1097\/IAE.0000000000001839","article-title":"A new design intraocular foreign body forceps","volume":"37","author":"Acar","year":"2017","journal-title":"Retina"},{"key":"R12-20250605","doi-asserted-by":"crossref","first-page":"1567","DOI":"10.1016\/S0161-6420(03)00488-3","article-title":"Clinical features and outcomes of pars plana vitrectomy in patients with retained lens fragments","volume":"110","author":"Scott","year":"2003","journal-title":"Ophthalmology"},{"key":"R13-20250605","doi-asserted-by":"crossref","first-page":"570","DOI":"10.1097\/00006982-200507000-00005","article-title":"Retinal tears and retinal detachment as factors affecting visual outcome after cataract extraction complicated by posteriorly dislocated lens material","volume":"25","author":"Salam","year":"2005","journal-title":"Retina"},{"key":"R14-20250605","doi-asserted-by":"crossref","first-page":"709","DOI":"10.1016\/S0161-6420(03)00020-4","article-title":"Retinal detachment in eyes undergoing pars plana vitrectomy for removal of retained lens fragments","volume":"110","author":"Moore","year":"2003","journal-title":"Ophthalmology"},{"key":"R15-20250605","doi-asserted-by":"crossref","first-page":"e434","DOI":"10.1111\/aos.13653","article-title":"Nitinol basket-assisted pars plana vitrectomy for retained lens material removal","volume":"96","author":"Iannetta","year":"2018","journal-title":"Acta Ophthalmol"}],"container-title":["Retina"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/IAE.0000000000003476","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,5]],"date-time":"2025-06-05T17:07:03Z","timestamp":1749143223000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/IAE.0000000000003476"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,12]]},"references-count":15,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.1097\/iae.0000000000003476","relation":{},"ISSN":["0275-004X"],"issn-type":[{"type":"print","value":"0275-004X"}],"subject":[],"published":{"date-parts":[[2023,12]]}}}