{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,15]],"date-time":"2026-01-15T06:52:25Z","timestamp":1768459945019,"version":"3.49.0"},"reference-count":13,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"12","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2023,12]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>To describe endoscope-assisted Carlevale intraocular lens (IOL) implantation.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>Twelve eyes underwent posterior vitrectomy combined with Carlevale IOL implantation and endoscopy in a single procedure, using a technique developed by the authors. Transscleral incisions were performed under direct visualization of the sulcus using the endoscope, and the final lens position was checked at the end of each intervention. The main outcome was to determine the exact position of all lens fixation points.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>All plugs were correctly placed in the sulcus, but in seven eyes (58.3%), at least one of the closed-loop haptics was folded over the ciliary body. Repositioning was performed during the same procedure. Given that each IOL has four closed-loop haptics, the incidence of this complication was 23% (11\/48).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion:<\/jats:title>\n            <jats:p>Blind implantation of Carlevale IOL may cause a high incidence of haptic malpositioning. Because the sulcus and the ciliary body are not visible under the microscope, endoscopy is the only way to ensure correct lens implantation. This new technique ensures that all lens fixation points are correctly placed by the end of surgery, avoiding complications such as decentration or tilting of the IOL, damage to the iris or the ciliary body, and uveitis.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/iae.0000000000003496","type":"journal-article","created":{"date-parts":[[2022,4,8]],"date-time":"2022-04-08T22:00:42Z","timestamp":1649455242000},"page":"2084-2088","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":6,"title":["Endoscope-Assisted Carlevale Lens Implantation in Patients Without Capsular Support: A Novel Surgical Approach to Ensure Correct Lens Positioning"],"prefix":"10.1097","volume":"43","author":[{"given":"Agnieszka","family":"Dyrda","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Maria S.","family":"Pighin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ignasi","family":"J\u00fcrgens","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20250605","doi-asserted-by":"crossref","first-page":"1234","DOI":"10.1016\/j.ophtha.2020.03.005","article-title":"Intraocular lens implantation in the absence of zonular support: an outcomes and safety update: a report by the American Academy of Ophthalmology","volume":"127","author":"Shen","year":"2020","journal-title":"Ophthalmology"},{"key":"R2-20250605","doi-asserted-by":"crossref","first-page":"612","DOI":"10.1177\/1120672120902020","article-title":"New surgical approach for sutureless scleral fixation","volume":"30","author":"Veronese","year":"2020","journal-title":"Eur J Ophthalmol"},{"key":"R3-20250605","doi-asserted-by":"crossref","first-page":"198","DOI":"10.1016\/j.survophthal.2020.11.004","article-title":"Endoscopic vitreoretinal surgery: review of current applications and future trends","volume":"66","author":"Lai","year":"2021","journal-title":"Surv Ophthalmol"},{"key":"R4-20250605","doi-asserted-by":"crossref","first-page":"879","DOI":"10.1016\/S0886-3350(96)80186-6","article-title":"Endoscope-assisted transscleral suture fixation of intraocular lenses","volume":"22","author":"J\u00fcrgens","year":"1996","journal-title":"J Cataract Refract Surg"},{"key":"R5-20250605","doi-asserted-by":"crossref","first-page":"716","DOI":"10.1097\/j.jcrs.0000000000000135","article-title":"Trans-scleral plugs fixated IOL: a new paradigm for sutureless scleral fixation","volume":"46","author":"Barca","year":"2020","journal-title":"J Cataract Refract Surg"},{"key":"R6-20250605","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1016\/S0002-9394(14)76337-8","article-title":"Histologic study of eyes with transsclerally sutured posterior chamber intraocular lenses","volume":"110","author":"Lubniewski","year":"1990","journal-title":"Am J Ophthalmol"},{"key":"R7-20250605","doi-asserted-by":"crossref","first-page":"573","DOI":"10.1016\/S0886-3350(13)80002-8","article-title":"Determination of haptic position of transsclerally fixated posterior chamber intraocular lenses by ultrasound biomicroscopy","volume":"19","author":"Pavlin","year":"1993","journal-title":"J Cataract Refract Surg"},{"key":"R8-20250605","doi-asserted-by":"crossref","first-page":"2172","DOI":"10.1016\/S0161-6420(00)00412-7","article-title":"Ultrasound biomicroscopic analysis of posterior chamber intraocular lenses with transscleral sulcus suture","volume":"107","author":"Manabe","year":"2000","journal-title":"Ophthalmology"},{"key":"R9-20250605","doi-asserted-by":"crossref","first-page":"1418","DOI":"10.1016\/S0886-3350(01)00791-X","article-title":"Ultrasound biomicroscopy of haptic position after transscleral fixation of posterior chamber intraocular lenses","volume":"27","author":"Sewelam","year":"2001","journal-title":"J Cataract Refract Surg"},{"key":"R10-20250605","doi-asserted-by":"crossref","first-page":"316","DOI":"10.1097\/j.jcrs.0000000000000444","article-title":"In vivo evaluation of a 1-piece foldable sutureless intrascleral fixation intraocular lens using ultrasound biomicroscopy and anterior segment OCT","volume":"47","author":"Mularoni","year":"2021","journal-title":"J Cataract Refract Surg"},{"key":"R11-20250605","doi-asserted-by":"crossref","first-page":"2947","DOI":"10.1177\/1120672121991358","article-title":"A novel approach for scleral fixation using Carlevale lens","volume":"31","author":"Fiore","year":"2021","journal-title":"Eur J Ophthalmol"},{"key":"R12-20250605","doi-asserted-by":"crossref","first-page":"126","DOI":"10.3928\/1081597X-20201207-02","article-title":"Long-term outcomes and complications of the new Carlevale sutureless scleral fixation posterior chamber IOL","volume":"37","author":"Vaiano","year":"2021","journal-title":"J Refract Surg"},{"key":"R13-20250605","doi-asserted-by":"crossref","first-page":"1777","DOI":"10.1016\/j.jcrs.2005.02.029","article-title":"Endoscope-assisted transscleral suture fixation to reduce the incidence of intraocular lens dislocation","volume":"31","author":"Sasahara","year":"2005","journal-title":"J Cataract Refract Surg"}],"container-title":["Retina"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/IAE.0000000000003496","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,5]],"date-time":"2025-06-05T17:05:56Z","timestamp":1749143156000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/IAE.0000000000003496"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,12]]},"references-count":13,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.1097\/iae.0000000000003496","relation":{},"ISSN":["0275-004X"],"issn-type":[{"value":"0275-004X","type":"print"}],"subject":[],"published":{"date-parts":[[2023,12]]}}}