{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,19]],"date-time":"2026-11-19T18:01:30Z","timestamp":1795111290196,"version":"4.10.3"},"reference-count":29,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"12","license":[{"start":{"date-parts":[[2022,11,17]],"date-time":"2022-11-17T00:00:00Z","timestamp":1668643200000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2023,12]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>To report the results of a novel surgical four-point transscleral suture fixation of intraocular lens (IOL) with four hollow haptics using the double-suture technique.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>We retrospectively reviewed the medical records of 15 eyes of 15 patients who underwent 4-point transscleral suture fixation of a foldable IOL using the double-suture technique. Preoperative data and follow-up data for at least 4 months were collected for all patients.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>The IOLs were fixed and centered well. The mean preoperative corrected distance visual acuity was 0.70 \u00b1 0.54 logarithm of the minimum angle of resolution (Snellen 20\/102), and it improved to 0.29 \u00b1 0.26 logarithm of the minimum angle of resolution (Snellen 20\/39) at the final follow-up (<jats:italic toggle=\"yes\">P =<\/jats:italic> 0.001). No vitreous hemorrhage, hypotony, suture breakage, retinal detachment, IOL dislocation, and iris capture was detected during the follow-up period in any of the patients.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion:<\/jats:title>\n            <jats:p>We have developed a novel technique for 4-point transscleral suture fixation of IOL using the double-suture technique with 9-0 polypropylene suture. This technique seemed to be safe and it may not require the surgeon to learn any new technique.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/iae.0000000000003601","type":"journal-article","created":{"date-parts":[[2022,8,19]],"date-time":"2022-08-19T04:00:09Z","timestamp":1660881609000},"page":"2059-2063","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":10,"title":["Four-Point Scleral Fixation of An Akreos Adapt AO Intraocular Lens Using Double-Strand 9-0 Polypropylene Suture"],"prefix":"10.1097","volume":"43","author":[{"given":"Shijiu","family":"Chen","sequence":"first","affiliation":[{"name":"Qingdao University, Qingdao, China;"},{"name":"Eye Hospital of Shandong First Medical University (Shandong Eye Hospital), Jinan, Shandong, China;"},{"name":"State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Eye Institute of Shandong First Medical University, Qingdao, Shandong Province, China; and"},{"name":"School of Ophthalmology, Shandong First Medical University, Jinan, Shandong, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gongqiang","family":"Yuan","sequence":"additional","affiliation":[{"name":"Eye Hospital of Shandong First Medical University (Shandong Eye Hospital), Jinan, Shandong, China;"},{"name":"School of Ophthalmology, Shandong First Medical University, Jinan, Shandong, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wenting","family":"Zhu","sequence":"additional","affiliation":[{"name":"Eye Hospital of Shandong First Medical University (Shandong Eye Hospital), Jinan, Shandong, China;"},{"name":"State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Eye Institute of Shandong First Medical University, Qingdao, Shandong Province, China; and"},{"name":"School of Ophthalmology, Shandong First Medical University, Jinan, Shandong, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qian","family":"Wang","sequence":"additional","affiliation":[{"name":"Eye Hospital of Shandong First Medical University (Shandong Eye Hospital), Jinan, Shandong, China;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Weiyun","family":"Shi","sequence":"additional","affiliation":[{"name":"Qingdao University, Qingdao, China;"},{"name":"Eye Hospital of Shandong First Medical University (Shandong Eye Hospital), Jinan, Shandong, China;"},{"name":"State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Eye Institute of Shandong First Medical University, Qingdao, Shandong Province, China; and"},{"name":"School of Ophthalmology, Shandong First Medical University, Jinan, Shandong, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jingjing","family":"Zhang","sequence":"additional","affiliation":[{"name":"Qingdao University, Qingdao, China;"},{"name":"Eye Hospital of Shandong First Medical University (Shandong Eye Hospital), Jinan, Shandong, China;"},{"name":"State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Eye Institute of Shandong First Medical University, Qingdao, Shandong Province, China; and"},{"name":"School of Ophthalmology, Shandong First Medical University, Jinan, Shandong, China."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2022,11,17]]},"reference":[{"key":"R1-20250605","doi-asserted-by":"crossref","first-page":"1579","DOI":"10.1016\/j.jcrs.2014.08.022","article-title":"Tiltless and centration adjustable scleralsutured posterior chamber intraocular lens","volume":"40","author":"Snyder","year":"2014","journal-title":"J Cataract Refractive Surg"},{"key":"R2-20250605","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1016\/j.jcrs.2014.11.012","article-title":"Simple technique to treat pupillary capture after transscleral fixation of intraocular lens","volume":"41","author":"J\u00fcrgens","year":"2015","journal-title":"J Cataract Refractive Surg"},{"key":"R3-20250605","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1016\/j.jcrs.2012.07.042","article-title":"Transscleral fixation of a supplementary toric intraocular lens to prevent rotation in a pseudophakic patient","volume":"39","author":"McGrath","year":"2013","journal-title":"J Cataract Refractive Surg"},{"key":"R4-20250605","doi-asserted-by":"crossref","first-page":"416","DOI":"10.1001\/archopht.1988.01060130442039","article-title":"Implantation of posterior chamber lens in the absence of capsular and zonular support","volume":"106","author":"Hu","year":"1988","journal-title":"Archives Ophthalmol"},{"key":"R5-20250605","doi-asserted-by":"crossref","first-page":"1271","DOI":"10.1016\/S0886-3350(98)80026-6","article-title":"Pupillary block after pupillary capture of an AcrySof intraocular lens","volume":"24","author":"Nagamoto","year":"1998","journal-title":"J Cataract Refractive Surg"},{"key":"R6-20250605","article-title":"8-0 polypropylene suture looping and overhand knot: transconjunctival approach to four-point scleral fixation of an akreos adapt intraocular lens","author":"Chen","year":"2020","journal-title":"Retina"},{"key":"R7-20250605","article-title":"Closed continuous-loop suture: a novel surgical technique for transscleral fixation of intraocular lenses","author":"Zhang","year":"2019","journal-title":"Retina"},{"key":"R8-20250605","doi-asserted-by":"crossref","first-page":"609","DOI":"10.1016\/j.jcrs.2013.09.014","article-title":"Outcomes of scleral-sutured conventional and aniridia intraocular lens implantation performed in a university hospital setting","volume":"40","author":"Lockington","year":"2014","journal-title":"J Cataract Refractive Surg"},{"key":"R9-20250605","doi-asserted-by":"crossref","first-page":"308","DOI":"10.1016\/j.ajo.2005.09.012","article-title":"Long-term outcome of combined pars plana vitrectomy and scleral fixated sutured posterior chamber intraocular lens implantation","volume":"141","author":"Vote","year":"2006","journal-title":"Am J Ophthalmol"},{"key":"R10-20250605","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1016\/j.ajo.2018.01.034","article-title":"Long term outcome of pars plana vitrectomy and sutured scleral-fixated posterior chamber intraocular lens implantation or repositioning","volume":"189","author":"Kokame","year":"2018","journal-title":"Am J Ophthalmol"},{"key":"R11-20250605","doi-asserted-by":"crossref","first-page":"371","DOI":"10.1016\/j.ajo.2007.05.014","article-title":"Long-term safety and functional outcome of combined pars plana vitrectomy and scleral-fixated sutured posterior chamber lens implantation","volume":"144","author":"Bading","year":"2007","journal-title":"Am J Ophthalmol"},{"key":"R12-20250605","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1016\/S0146-2776(83)80028-7","article-title":"Estimation of the useful lifetime of polypropylene fiber in the anterior chamber","volume":"9","author":"Mowbray","year":"1983","journal-title":"J Am Intraocular Implant Soc"},{"key":"R13-20250605","doi-asserted-by":"crossref","first-page":"854","DOI":"10.1016\/j.jcrs.2003.09.050","article-title":"Transscleral fixation of foldable intraocular lenses","volume":"30","author":"Kaynak","year":"2004","journal-title":"J Cataract Refractive Surg"},{"key":"R14-20250605","doi-asserted-by":"crossref","first-page":"431","DOI":"10.1016\/j.jaapos.2008.04.016","article-title":"Safety of transscleral-sutured intraocular lenses in children","volume":"12","author":"Buckley","year":"2008","journal-title":"J Am Assoc Pediatr Ophthalmol Strabismus"},{"key":"R15-20250605","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1007\/BF00166695","article-title":"Degradation of polypropylene in the human eye: a SEM-study","volume":"64","author":"Jongebloed","year":"1986","journal-title":"Documenta Ophthalmologica"},{"key":"R16-20250605","doi-asserted-by":"crossref","first-page":"212","DOI":"10.1159\/000365350","article-title":"Haptic breakage after transscleral fixation of a single-piece acrylic intraocular lens","volume":"5","author":"Tanaka","year":"2014","journal-title":"Case Rep Ophthalmol"},{"key":"R17-20250605","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s12886-015-0102-3","article-title":"Exposure of haptic of posterior chamber intraocular lens after sutureless intrascleral fixation","volume":"15","author":"Matsui","year":"2015","journal-title":"Bmc Ophthalmol"},{"key":"R18-20250605","doi-asserted-by":"crossref","first-page":"1136","DOI":"10.1016\/j.ophtha.2017.03.036","article-title":"Flanged intrascleral intraocular lens fixation with double-needle technique","volume":"124","author":"Yamane","year":"2017","journal-title":"Ophthalmology"},{"key":"R19-20250605","doi-asserted-by":"crossref","first-page":"1433","DOI":"10.1016\/j.jcrs.2008.04.040","article-title":"Fibrin glue\u2013assisted sutureless posterior chamber intraocular lens implantation in eyes with deficient posterior capsules","volume":"34","author":"Agarwal","year":"2008","journal-title":"J Cataract Refractive Surg"},{"key":"R20-20250605","doi-asserted-by":"crossref","first-page":"1320","DOI":"10.1016\/j.jcrs.2004.12.060","article-title":"Late dislocation of scleral-sutured posterior chamber intraocular lenses","volume":"31","author":"Price","year":"2005","journal-title":"J Cataract Refractive Surg"},{"key":"R21-20250605","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1177\/2474126417690650","article-title":"Scleral-fixated intraocular lenses: past and present","volume":"1","author":"Stem","year":"2017","journal-title":"J Vitreoretinal Dis"},{"key":"R22-20250605","doi-asserted-by":"crossref","first-page":"1421","DOI":"10.1016\/j.jcrs.2018.08.008","article-title":"New use of 8-0 polypropylene suture for four-point scleral fixation of secondary intraocular lenses","volume":"44","author":"John","year":"2018","journal-title":"J Cataract Refractive Surg"},{"key":"R23-20250605","doi-asserted-by":"crossref","first-page":"1141","DOI":"10.1016\/S0886-3350(02)01425-6","article-title":"Results of hydrophilic acrylic, hydrophobic acrylic, and silicone intraocular lenses in uveitic eyes with cataract: comparison to a control group","volume":"28","author":"Abela-Formanek","year":"2002","journal-title":"J Cataract Refractive Surg"},{"key":"R24-20250605","doi-asserted-by":"crossref","first-page":"497","DOI":"10.1016\/j.jcrs.2015.01.003","article-title":"Friction knot to fixate scleral sutures","volume":"41","author":"Oskala","year":"2015","journal-title":"J Cataract Refractive Surg"},{"key":"R25-20250605","first-page":"NC09","article-title":"Posterior chamber scleral fixation of intraocular lenses in post-vitrectomised aphakic eyes","volume":"11","author":"Obeng","year":"2017","journal-title":"J Clin Diagn Res"},{"key":"R26-20250605","doi-asserted-by":"crossref","first-page":"638","DOI":"10.1136\/bjophthalmol-2015-306839","article-title":"Scleral fixation of intraocular lenses using Gore-tex suture: clinical outcomes and safety profile","volume":"100","author":"Khan","year":"2016","journal-title":"Br J Ophthalmol"},{"key":"R27-20250605","doi-asserted-by":"crossref","first-page":"1377","DOI":"10.1097\/IAE.0000000000001692","article-title":"Combined pars plana vitrectomy and scleral fixation of an intraocular lens using Gore-TX suture: one-year outcomes","volume":"38","author":"Khan","year":"2018","journal-title":"Retina"},{"key":"R28-20250605","doi-asserted-by":"crossref","first-page":"82","DOI":"10.1186\/s12886-016-0268-3","article-title":"Akreos adapt AO Intraocular lens opacification after vitrectomy in a diabetic patient: a case report and review of the literature","volume":"16","author":"Cao","year":"2016","journal-title":"BMC Ophthalmol"},{"key":"R29-20250605","doi-asserted-by":"crossref","first-page":"e188","DOI":"10.1016\/j.jcjo.2018.01.014","article-title":"Akreos lens opacification under silicone oil","volume":"53","author":"Rubin","year":"2018","journal-title":"Can J Ophthalmol J Canadien D'ophtalmol"}],"container-title":["Retina"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/IAE.0000000000003601","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,5]],"date-time":"2025-06-05T17:05:44Z","timestamp":1749143144000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/IAE.0000000000003601"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,11,17]]},"references-count":29,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.1097\/iae.0000000000003601","relation":{},"ISSN":["0275-004X"],"issn-type":[{"value":"0275-004X","type":"print"}],"subject":[],"published":{"date-parts":[[2022,11,17]]}}}