{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,26]],"date-time":"2026-02-26T09:00:17Z","timestamp":1772096417516,"version":"3.50.1"},"reference-count":9,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"12","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2023,12]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>To demonstrate a mathematical analogy between the Pythagorean theorem using the axial a-scan measurement, i.e., the distance between the central cornea and the sclerotomy, and the lengths of the forceps in eyes of patients with all axial lengths.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>We used the Pythagorean equation (c<jats:sup>2<\/jats:sup> = a<jats:sup>2<\/jats:sup> + b<jats:sup>2<\/jats:sup>) to calculate the adequate shaft length of the forceps to use in macular surgery, especially in highly myopic eyes, where c<jats:sup>2<\/jats:sup> represents the axial length (hypotenuse); b<jats:sup>2<\/jats:sup> the sum of the corneal ray and distance between the corneal limbus and the sclerotomy (base side); and a<jats:sup>2<\/jats:sup> the distance between the sclerotomy and the fovea (perpendicular side).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>We reproduced the cosine law to estimate the distance between the sclerotomy and the fovea. The distance between the sclerotomy and the foveal area is shorter than the axial length and can become smaller based on the distance from the sclerotomy to the corneal limbus.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion:<\/jats:title>\n            <jats:p>This simple mathematical formula is useful when performing surgery in highly myopic eyes, in which there can be difficulties reaching the macular area.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/iae.0000000000003704","type":"journal-article","created":{"date-parts":[[2023,2,2]],"date-time":"2023-02-02T17:21:23Z","timestamp":1675358483000},"page":"2166-2169","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["The Cosine Law to Choose the Correct Forceps Shaft Length for Macular Surgery in Highly Myopic Eyes"],"prefix":"10.1097","volume":"43","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7585-712X","authenticated-orcid":false,"given":"Anderson","family":"Teixeira","sequence":"first","affiliation":[{"name":"Medical School, Catholic University of Bras\u00edlia, Bras\u00edlia, DF, Brazil;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Camila","family":"Salaroli","sequence":"additional","affiliation":[{"name":"Cl\u00ednica de Olhos Teixeira Pinto, Bras\u00edlia, DF, Brazil."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Raphaela M.","family":"Fuganti","sequence":"additional","affiliation":[{"name":"Medical School, State University of Londrina, Londrina, PR, Brazil; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ant\u00f4nio Marcelo B.","family":"casella","sequence":"additional","affiliation":[{"name":"Medical School, State University of Londrina, Londrina, PR, Brazil; and"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20250605","doi-asserted-by":"crossref","first-page":"414","DOI":"10.1016\/j.ajo.2005.09.009","article-title":"Reoperation for persistent myopic foveoschisis after primary vitrectomy","volume":"141","author":"Sayanagi","year":"2006","journal-title":"Am J Ophthalmol"},{"key":"R2-20250605","doi-asserted-by":"crossref","first-page":"560","DOI":"10.1097\/00006982-200408000-00009","article-title":"Efficacy of internal limiting membrane removal for retinal detachments resulting from a myopic macular hole","volume":"24","author":"Uemoto","year":"2004","journal-title":"Retina"},{"key":"R3-20250605","doi-asserted-by":"crossref","first-page":"885","DOI":"10.1136\/bjo.87.7.885","article-title":"Internal limiting membrane removal in macular hole surgery for severely myopic eyes: a case-control study","volume":"87","author":"Kwok","year":"2003","journal-title":"Br J Ophthalmol"},{"key":"R4-20250605","doi-asserted-by":"crossref","first-page":"1475","DOI":"10.1097\/IAE.0b013e318297f85b","article-title":"Long-shaft forceps for membrane peeling in highly myopic eyes","volume":"33","author":"Gao","year":"2013","journal-title":"Retina"},{"key":"R5-20250605","doi-asserted-by":"crossref","first-page":"1137","DOI":"10.1007\/s00417-012-1935-6","article-title":"Paracentral retinal holes occurring after macular surgery: incidence, clinical features, and evolution","volume":"250","author":"Sandali","year":"2012","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"R6-20250605","doi-asserted-by":"crossref","first-page":"1199","DOI":"10.1097\/IAE.0000000000003025","article-title":"Extending the limbus-to-cannula distance to 6.0 mm during pars plana vitrectomy in highly myopic eyes","volume":"42","author":"Iwama","year":"2022","journal-title":"Retina"},{"key":"R7-20250605","doi-asserted-by":"crossref","first-page":"259","DOI":"10.1097\/01.ico.0000148312.01805.53","article-title":"White-to-white corneal diameter: normal values in healthy humans obtained with the Orbscan II topography system","volume":"24","author":"R\u00fcfer","year":"2005","journal-title":"Cornea"},{"key":"R8-20250605","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1097\/ICO.0b013e3181a9d0a9","article-title":"White-to-white corneal diameter in the tehran eye study","volume":"29","author":"Hashemi","year":"2010","journal-title":"Cornea"},{"key":"R9-20250605","doi-asserted-by":"crossref","first-page":"429","DOI":"10.1111\/j.1444-0938.2009.00407.x","article-title":"Comparison of horizontal corneal diameter measurements using Galilei, EyeSys and Orbscan II systems","volume":"92","author":"Salouti","year":"2009","journal-title":"Clin Exp Optom"}],"container-title":["Retina"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/IAE.0000000000003704","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,5]],"date-time":"2025-06-05T17:07:01Z","timestamp":1749143221000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/IAE.0000000000003704"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,12]]},"references-count":9,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.1097\/iae.0000000000003704","relation":{},"ISSN":["0275-004X"],"issn-type":[{"value":"0275-004X","type":"print"}],"subject":[],"published":{"date-parts":[[2023,12]]}}}