{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,25]],"date-time":"2026-03-25T04:54:16Z","timestamp":1774414456757,"version":"3.50.1"},"reference-count":18,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"12","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2023,12]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>The aim of this study was to evaluate the accessibility and potential value of intraoperative optical coherence tomography (iOCT) during scleral suture intraocular lens (IOL) fixation.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>This was a prospective cohort study in the Department of Ophthalmology, Eye and ENT Hospital, Fudan University, China. Seven eyes with insufficient capsular support and undergoing two-point scleral suture IOL fixation were included. The potential value of iOCT was evaluated, as well as the safety and efficacy of the surgery.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>Seven eyes were included. With a tailor-made iOCT, the structure of the anterior segment could be clearly visualized during the surgery. Intraoperatively, iOCT helped locate the proper place for fixation and access the position of the IOL. After an average 4.43-month follow-up, the spherical equivalent changed significantly (<jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.001), but the intraocular pressure, best-corrected visual acuity, and endothelial cell density remained unchanged (<jats:italic toggle=\"yes\">P<\/jats:italic> &gt; 0.05). The IOL was well-centered with a horizontal and a vertical tilt of 0.74 \u00b1 0.60\u00b0 and 1.13 \u00b1 0.65\u00b0, and decentration of 0.28 \u00b1 0.12 mm and 0.30 \u00b1 0.13 mm. The estimated IOL-induced astigmatism was \u22120.11 diopters (D) \u00b1 0.46 D.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion:<\/jats:title>\n            <jats:p>Real-time high-resolution images of the anterior segment acquired by the iOCT helped the surgeon to achieve satisfactory results in scleral suture IOL fixation.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/iae.0000000000003799","type":"journal-article","created":{"date-parts":[[2023,3,30]],"date-time":"2023-03-30T21:20:04Z","timestamp":1680211204000},"page":"2089-2095","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":3,"title":["Scleral Suture Intraocular Lens Fixation Under Microscope\u2013Intraoperative Optical Coherence Tomography"],"prefix":"10.1097","volume":"43","author":[{"given":"Jiemei","family":"Shi","sequence":"first","affiliation":[{"name":"Department of Ophthalmology and Vision Science, Eye and ENT Hospital, Fudan University, Shanghai, People's Republic of China;"},{"name":"Key Laboratory of Myopia of State Health Ministry, and Key Laboratory of Visual Impairment and Restoration of Shanghai, Shanghai, People's Republic of China; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tongjie","family":"Cheng","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology and Vision Science, Eye and ENT Hospital, Fudan University, Shanghai, People's Republic of China;"},{"name":"Key Laboratory of Myopia of State Health Ministry, and Key Laboratory of Visual Impairment and Restoration of Shanghai, Shanghai, People's Republic of China; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hongmei","family":"Zhao","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology and Vision Science, Eye and ENT Hospital, Fudan University, Shanghai, People's Republic of China;"},{"name":"Key Laboratory of Myopia of State Health Ministry, and Key Laboratory of Visual Impairment and Restoration of Shanghai, Shanghai, People's Republic of China; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jinyu","family":"Fan","sequence":"additional","affiliation":[{"name":"Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, Jiangsu Province, China."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tianliang","family":"Jiang","sequence":"additional","affiliation":[{"name":"Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, Jiangsu Province, China."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ning","family":"Tang","sequence":"additional","affiliation":[{"name":"Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, Jiangsu Province, China."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yunyao","family":"Li","sequence":"additional","affiliation":[{"name":"Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, Jiangsu Province, China."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kaicheng","family":"Wu","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology and Vision Science, Eye and ENT Hospital, Fudan University, Shanghai, People's Republic of China;"},{"name":"Key Laboratory of Myopia of State Health Ministry, and Key Laboratory of Visual Impairment and Restoration of Shanghai, Shanghai, People's Republic of China; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Guohua","family":"Shi","sequence":"additional","affiliation":[{"name":"Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, Jiangsu Province, China."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chunhui","family":"Jiang","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology and Vision Science, Eye and ENT Hospital, Fudan University, Shanghai, People's Republic of China;"},{"name":"Key Laboratory of Myopia of State Health Ministry, and Key Laboratory of Visual Impairment and Restoration of Shanghai, Shanghai, People's Republic of China; and"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20250605","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1097\/ICU.0000000000000260","article-title":"Management of dislocated intraocular lenses in eyes with insufficient capsular support","volume":"27","author":"Dajee","year":"2016","journal-title":"Curr Opin Ophthalmol"},{"key":"R2-20250605","doi-asserted-by":"crossref","first-page":"416","DOI":"10.1001\/archopht.1988.01060130442039","article-title":"Implantation of posterior chamber lens in the absence of capsular and zonular support","volume":"106","author":"Hu","year":"1988","journal-title":"Arch Ophthalmol"},{"key":"R3-20250605","doi-asserted-by":"crossref","first-page":"180","DOI":"10.1016\/j.ajoc.2018.02.025","article-title":"Adjustments of haptics length for tilted intraocular lens after intrascleral fixation","volume":"10","author":"Kurimori","year":"2018","journal-title":"Am J Ophthalmol Case Rep"},{"key":"R4-20250605","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1038\/eye.2015.255","article-title":"Intraoperative optical coherence tomography: past, present, and future","volume":"30","author":"Ehlers","year":"2016","journal-title":"Eye (Lond)"},{"key":"R5-20250605","doi-asserted-by":"crossref","first-page":"2212","DOI":"10.1016\/j.ophtha.2011.04.012","article-title":"Intraoperative microscope-mounted spectral domain optical coherence tomography for evaluation of retinal anatomy during macular surgery","volume":"118","author":"Ray","year":"2011","journal-title":"Ophthalmology"},{"key":"R6-20250605","doi-asserted-by":"crossref","first-page":"e20","DOI":"10.1097\/IAE.0000000000001979","article-title":"Intraoperative optical coherence tomography imaging of the peripheral vitreous and retina","volume":"38","author":"Nishitsuka","year":"2018","journal-title":"Retina"},{"key":"R7-20250605","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1167\/tvst.9.7.18","article-title":"Microscope-integrated intraoperative optical coherence tomography for anterior segment surgical maneuvers","volume":"9","author":"Fang","year":"2020","journal-title":"Transl Vis Sci Technol"},{"key":"R8-20250605","doi-asserted-by":"crossref","first-page":"167","DOI":"10.1136\/bjo.2009.162180","article-title":"Z-suture: a new knotless technique for transscleral suture fixation of intraocular implants","volume":"94","author":"Szurman","year":"2010","journal-title":"Br J Ophthalmol"},{"key":"R9-20250605","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1016\/j.jcrs.2005.06.050","article-title":"Ab externo scleral suture loop fixation for posterior chamber intraocular lens decentration: clinical results","volume":"32","author":"Chan","year":"2006","journal-title":"J Cataract Refract Surg"},{"key":"R10-20250605","doi-asserted-by":"crossref","first-page":"1809","DOI":"10.1097\/IAE.0000000000002536","article-title":"Management of dislocated crystalline lens with vitrectomy, perfluorocarbon liquid, and phacoemulsification, combined with modified capsular tension ring and in-the-bag intraocular lens implantation","volume":"42","author":"Zong","year":"2022","journal-title":"Retina"},{"key":"R11-20250605","doi-asserted-by":"crossref","first-page":"573","DOI":"10.1016\/S0886-3350(13)80002-8","article-title":"Determination of haptic position of transsclerally fixated posterior chamber intraocular lenses by ultrasound biomicroscopy","volume":"19","author":"Pavlin","year":"1993","journal-title":"J Cataract Refract Surg"},{"key":"R12-20250605","doi-asserted-by":"crossref","first-page":"1418","DOI":"10.1016\/S0886-3350(01)00791-X","article-title":"Ultrasound biomicroscopy of haptic position after transscleral fixation of posterior chamber intraocular lenses","volume":"27","author":"Sewelam","year":"2001","journal-title":"J Cataract Refract Surg"},{"key":"R13-20250605","doi-asserted-by":"crossref","first-page":"1247","DOI":"10.1016\/j.jcrs.2018.07.017","article-title":"Anatomy of the ciliary sulcus and the optimum site of needle passage for intraocular lens suture fixation in the living eye","volume":"44","author":"Sugiura","year":"2018","journal-title":"J Cataract Refract Surg"},{"key":"R14-20250605","doi-asserted-by":"crossref","first-page":"162","DOI":"10.1016\/j.jcrs.2016.10.029","article-title":"Modified technique for intrascleral fixation of posterior chamber intraocular lens without scleral flaps","volume":"43","author":"Zhang","year":"2017","journal-title":"J Cataract Refract Surg"},{"key":"R15-20250605","doi-asserted-by":"crossref","first-page":"1573","DOI":"10.1097\/j.jcrs.0000000000000832","article-title":"Dimensions of the limbus-ciliary sulcus region by OCT and correlation study in a large population","volume":"47","author":"Fern\u00e1ndez-Vigo","year":"2021","journal-title":"J Cataract Refract Surg"},{"key":"R16-20250605","doi-asserted-by":"crossref","first-page":"1308","DOI":"10.1097\/j.jcrs.0000000000000615","article-title":"Adjustment of intraocular lens tilt during intrascleral fixation assisted by intraoperative OCT","volume":"47","author":"Fukumoto","year":"2021","journal-title":"J Cataract Refract Surg"},{"key":"R17-20250605","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1016\/S0886-3350(00)00638-6","article-title":"Tilt and decentration after primary and secondary transsclerally sutured posterior chamber intraocular lens implantation","volume":"27","author":"Durak","year":"2001","journal-title":"J Cataract Refract Surg"},{"key":"R18-20250605","doi-asserted-by":"crossref","first-page":"180","DOI":"10.3928\/1081597X-20201222-01","article-title":"Transfixion of foldable intraocular lens with polytetrafluoroethylene suture for scleral fixation","volume":"37","author":"Pineda-Fern\u00e1ndez","year":"2021","journal-title":"J Refract Surg"}],"container-title":["Retina"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/IAE.0000000000003799","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,5]],"date-time":"2025-06-05T17:07:12Z","timestamp":1749143232000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/IAE.0000000000003799"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,12]]},"references-count":18,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.1097\/iae.0000000000003799","relation":{},"ISSN":["0275-004X"],"issn-type":[{"value":"0275-004X","type":"print"}],"subject":[],"published":{"date-parts":[[2023,12]]}}}