{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,23]],"date-time":"2026-04-23T21:17:30Z","timestamp":1776979050319,"version":"3.51.4"},"reference-count":31,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2024,4]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>To investigate surgical results for medium-sized (251\u2013400 <jats:italic toggle=\"yes\">\u00b5<\/jats:italic>m) macular holes (MHs).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>This retrospective observational study involved 266 eyes of 262 consecutive patients who underwent internal limiting membrane (ILM) peeling (147 eyes in the ILM peeling group) or inverted ILM flap cover technique (119 eyes in the inverted flap group) for primary medium-sized full-thickness MHs. Macular hole associated with retinal detachment, recurrent MH, and traumatic MH were excluded.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>The primary closure rate for overall medium-sized MHs was 100% (119 of 119 eyes) in the inverted flap group, which was significantly higher than that (94.6% [139\/147 eyes]; <jats:italic toggle=\"yes\">P<\/jats:italic> = 0.010) in the ILM peeling group. Notably, even after adjusting for the minimum MH diameter, presence of high myopia, or preexisting posterior vitreous detachment, the primary closure rate was significantly better in the inverted flap group than in the ILM peeling group (Cochran\u2013Mantel\u2013Haenszel test, overall adjusted <jats:italic toggle=\"yes\">P<\/jats:italic> = 0.006, 0.009, 0.005, respectively). The preoperative and postoperative restoration of the outer retinal layers and visual acuity were comparable between the inverted ILM flap and ILM peeling techniques.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion:<\/jats:title>\n            <jats:p>Primary closure for medium-sized MHs was significantly superior in the inverted flap group than in the ILM peeling group.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/iae.0000000000004022","type":"journal-article","created":{"date-parts":[[2023,12,13]],"date-time":"2023-12-13T22:00:09Z","timestamp":1702504809000},"page":"635-641","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":5,"title":["A COMPARATIVE STUDY OF MEDIUM-SIZED MACULAR HOLE SURGERY WITH INVERTED INTERNAL LIMITING MEMBRANE FLAP TECHNIQUE VERSUS CONVENTIONAL PEELING"],"prefix":"10.1097","volume":"44","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7397-8654","authenticated-orcid":false,"given":"Masanori","family":"Iwasaki","sequence":"first","affiliation":[{"name":"Department of Ophthalmology, Nihon University School of Medicine, Tokyo, Japan;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5801-8893","authenticated-orcid":false,"given":"Hiroyuki","family":"Nakashizuka","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Nihon University School of Medicine, Tokyo, Japan;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3323-4148","authenticated-orcid":false,"given":"Koji","family":"Tanaka","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Nihon University School of Medicine, Tokyo, Japan;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yu","family":"Wakatsuki","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Nihon University School of Medicine, Tokyo, Japan;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hajime","family":"Onoe","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Nihon University School of Medicine, Tokyo, Japan;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takuya","family":"Sakakibara","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Nihon University School of Medicine, Tokyo, Japan;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Naoya","family":"Nakagawa","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Nihon University School of Medicine, Tokyo, Japan;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Taishi","family":"Fujimiya","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Nihon University School of Medicine, Tokyo, Japan;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sawako","family":"Koutari","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Nihon University School of Medicine, Tokyo, Japan;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yorihisa","family":"Kitagawa","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Nihon University School of Medicine, Tokyo, Japan;"},{"name":"Kobari General Hospital;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hattori","family":"Takayuki","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Nihon University School of Medicine, Tokyo, Japan;"},{"name":"Kasukabe Medical Center; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ryusaburo","family":"Mori","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Nihon University School of Medicine, Tokyo, Japan;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hiroyuki","family":"Shimada","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Nihon University School of Medicine, Tokyo, Japan;"},{"name":"Miyahara Eye Clinic."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20250605","doi-asserted-by":"crossref","first-page":"1150","DOI":"10.1016\/S0161-6420(01)00581-4","article-title":"Long-term follow-up of unoperated macular holes","volume":"108","author":"Casuso","year":"2001","journal-title":"Ophthalmology"},{"key":"R2-20250605","doi-asserted-by":"crossref","first-page":"311","DOI":"10.1097\/00006982-200507001-00009","article-title":"A histopathologic study of macular cysts and holes","volume":"25","author":"Frangieh","year":"2005","journal-title":"Retina"},{"key":"R3-20250605","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1001\/archopht.118.1.41","article-title":"The visual performance and metamorphopsia of patients with macular holes","volume":"118","author":"Saito","year":"2000","journal-title":"Arch Ophthalmol"},{"key":"R4-20250605","doi-asserted-by":"crossref","first-page":"371","DOI":"10.1016\/0002-9394(88)90300-5","article-title":"Vitrectomy for impending idiopathic macular holes","volume":"105","author":"Smiddy","year":"1988","journal-title":"Am J Ophthalmol"},{"key":"R5-20250605","doi-asserted-by":"crossref","first-page":"1392","DOI":"10.1016\/S0161-6420(99)00730-7","article-title":"Macular hole surgery with internal-limiting membrane peeling and intravitreous air","volume":"106","author":"Park","year":"1999","journal-title":"Ophthalmology"},{"key":"R6-20250605","doi-asserted-by":"crossref","first-page":"316","DOI":"10.1038\/s41433-020-0844-x","article-title":"Factors affecting anatomical and visual outcome after macular hole surgery: findings from a large prospective UK cohort","volume":"35","author":"Steel","year":"2021","journal-title":"Eye (Lond)"},{"key":"R7-20250605","doi-asserted-by":"crossref","first-page":"341","DOI":"10.1097\/00006982-200406000-00001","article-title":"Vitrectomy for chronic macular holes","volume":"24","author":"Stec","year":"2004","journal-title":"Retina"},{"key":"R8-20250605","doi-asserted-by":"crossref","first-page":"118","DOI":"10.1016\/j.ajo.2010.07.007","article-title":"Axial length and outcomes of macular hole surgery assessed by spectral-domain optical coherence tomography","volume":"151","author":"Suda","year":"2011","journal-title":"Am J Ophthalmol"},{"key":"R9-20250605","doi-asserted-by":"crossref","first-page":"2018","DOI":"10.1016\/j.ophtha.2010.02.011","article-title":"Inverted internal limiting membrane flap technique for large macular holes","volume":"117","author":"Michalewska","year":"2010","journal-title":"Ophthalmology"},{"key":"R10-20250605","doi-asserted-by":"crossref","first-page":"2251","DOI":"10.1097\/IAE.0000000000003622","article-title":"Conventional internal limiting membrane peeling versus inverted flap for small-to-medium idiopathic macular hole: a randomized trial","volume":"42","author":"Ventre","year":"2022","journal-title":"Retina"},{"key":"R11-20250605","doi-asserted-by":"crossref","first-page":"771","DOI":"10.1016\/j.survophthal.2021.02.010","article-title":"Inverted internal limiting membrane flap technique for myopic macular hole: a meta-analysis","volume":"66","author":"Chatziralli","year":"2021","journal-title":"Surv Ophthalmol"},{"key":"R12-20250605","doi-asserted-by":"crossref","first-page":"713","DOI":"10.1159\/000515283","article-title":"Inverted internal limiting membrane flap technique versus internal limiting membrane peeling for large macular holes: a meta-analysis of randomized controlled trials","volume":"64","author":"Yu","year":"2021","journal-title":"Ophthalmic Res"},{"key":"R13-20250605","doi-asserted-by":"crossref","first-page":"633","DOI":"10.1016\/S0002-9394(02)02240-7","article-title":"Long-term anatomic and visual acuity outcomes after initial anatomic success with macular hole surgery","volume":"135","author":"Scott","year":"2003","journal-title":"Am J Ophthalmol"},{"key":"R14-20250605","doi-asserted-by":"crossref","first-page":"2611","DOI":"10.1016\/j.ophtha.2013.07.042","article-title":"The international vitreomacular traction study group classification of vitreomacular adhesion, traction, and macular hole","volume":"120","author":"Duker","year":"2013","journal-title":"Ophthalmology"},{"key":"R15-20250605","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1097\/IAE.0000000000001985","article-title":"Internal limiting membrane peeling versus inverted flap technique for treatment of full-thickness macular holes a comparative study in a large series of patients","volume":"38","author":"Rizzo","year":"2018","journal-title":"Retina"},{"key":"R16-20250605","doi-asserted-by":"crossref","first-page":"1955","DOI":"10.1097\/IAE.0000000000002707","article-title":"Effect of inverted internal limiting membrane flap on closure rate, postoperative visual acuity, and restoration of outer retinal layers in primary idiopathic macular hole surgery","volume":"40","author":"Baumann","year":"2020","journal-title":"Retina"},{"key":"R17-20250605","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1016\/j.ajo.2021.08.016","article-title":"Single-layer inverted internal limiting membrane flap versus conventional peel for small- or medium-sized full-thickness macular holes","volume":"235","author":"Chou","year":"2022","journal-title":"Am J Ophthalmol"},{"key":"R18-20250605","doi-asserted-by":"crossref","first-page":"828","DOI":"10.1016\/j.oret.2022.04.003","article-title":"Air versus sulfur hexafluoride gas tamponade for small and medium sized macular holes: a randomized noninferiority trial","volume":"6","author":"Lindtj\u00f8rn","year":"2022","journal-title":"Ophthalmol Retina"},{"key":"R19-20250605","doi-asserted-by":"crossref","first-page":"2521","DOI":"10.1007\/s00417-013-2347-y","article-title":"Assessment of OCT measurements as prognostic factors in myopic macular hole surgery without foveoschisis","volume":"251","author":"Alkabes","year":"2013","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"R20-20250605","doi-asserted-by":"crossref","first-page":"332","DOI":"10.1097\/00006982-200108000-00006","article-title":"The role of vitreoretinal surgery in the management of myopic macular hole without retinal detachment","volume":"21","author":"Garc\u00eda-Arum\u00ed","year":"2001","journal-title":"Retina"},{"key":"R21-20250605","doi-asserted-by":"crossref","first-page":"743","DOI":"10.1097\/IAE.0000000000002013","article-title":"Macular hole hydrodissection surgical technique for the treatment of persistent, chronic, and large macular holes","volume":"39","author":"Felfeli","year":"2019","journal-title":"Retina"},{"key":"R22-20250605","doi-asserted-by":"crossref","first-page":"752","DOI":"10.1016\/S0002-9394(14)72781-3","article-title":"Reappraisal of biomicroscopic classification of stages of development of a macular hole","volume":"119","author":"Gass","year":"1995","journal-title":"Am J Ophthalmol"},{"key":"R23-20250605","doi-asserted-by":"crossref","first-page":"152","DOI":"10.1016\/j.ophtha.2022.08.028","article-title":"The effect of macular hole duration on surgical outcomes: an individual participant data study of randomized controlled trials","volume":"130","author":"Murphy","year":"2023","journal-title":"Ophthalmology"},{"key":"R24-20250605","doi-asserted-by":"crossref","first-page":"4847","DOI":"10.1167\/iovs.17-21756","article-title":"The role of inverted internal limiting membrane flap in macular hole closure","volume":"58","author":"Shiode","year":"2017","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R25-20250605","doi-asserted-by":"crossref","first-page":"1564","DOI":"10.1136\/bjo.2010.195826","article-title":"Re-operation of idiopathic full-thickness macular holes after initial surgery with internal limiting membrane peel","volume":"95","author":"D'Souza","year":"2011","journal-title":"Br J Ophthalmol"},{"key":"R26-20250605","doi-asserted-by":"crossref","first-page":"757","DOI":"10.1016\/j.oret.2017.10.012","article-title":"Outcomes of eyes with failed primary surgery for idiopathic macular hole","volume":"2","author":"Yek","year":"2018","journal-title":"Ophthalmol Retina"},{"key":"R27-20250605","doi-asserted-by":"crossref","first-page":"100","DOI":"10.1016\/j.ajo.2015.03.019","article-title":"Correlation between the dynamic postoperative visual outcome and the restoration of foveal microstructures after macular hole surgery","volume":"160","author":"Chang","year":"2015","journal-title":"Am J Ophthalmol"},{"key":"R28-20250605","doi-asserted-by":"crossref","first-page":"453","DOI":"10.1097\/IAE.0b013e3181571398","article-title":"Correlation of visual recovery and presence of photoreceptor inner\/outer segment junction in optical coherence images after successful macular hole repair","volume":"28","author":"Baba","year":"2008","journal-title":"Retina"},{"key":"R29-20250605","doi-asserted-by":"crossref","first-page":"1815","DOI":"10.1016\/j.ophtha.2010.01.017","article-title":"Foveal microstructure and visual acuity in surgically closed macular holes: spectral-domain optical coherence tomographic analysis","volume":"117","author":"Wakabayashi","year":"2010","journal-title":"Ophthalmology"},{"key":"R30-20250605","doi-asserted-by":"crossref","first-page":"423","DOI":"10.1016\/j.preteyeres.2009.07.001","article-title":"Cellular signaling and factors involved in M\u00fcller cell gliosis: neuroprotective and detrimental effects","volume":"28","author":"Bringmann","year":"2009","journal-title":"Prog Retin Eye Res"},{"key":"R31-20250605","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1159\/000507501","article-title":"Magnification effect of foveal avascular zone measurement using optical coherence tomography angiography","volume":"5","author":"Suda","year":"2020","journal-title":"Biomed Hub"}],"container-title":["Retina"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/IAE.0000000000004022","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,5]],"date-time":"2025-06-05T17:02:18Z","timestamp":1749142938000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/IAE.0000000000004022"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,4]]},"references-count":31,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.1097\/iae.0000000000004022","relation":{},"ISSN":["0275-004X"],"issn-type":[{"value":"0275-004X","type":"print"}],"subject":[],"published":{"date-parts":[[2024,4]]}}}