{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,20]],"date-time":"2026-04-20T02:58:04Z","timestamp":1776653884870,"version":"3.51.2"},"reference-count":9,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"11","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2024,11]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>To describe the technique of modified girth-hitch suture for one-side transscleral fixation to rescue a single-haptic dislocation.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>In this surgical technique report, dislocated scleral-fixated posterior-chamber intraocular lenses (IOLs) were secured to the sclera using a 10-0 polypropylene suture looped around the IOL haptic. Three types of IOL were secured in this study (four cases of one-piece polymethyl methacrylate (PMMA) IOL, one case of three-piece acrylic IOL with PMMA loop, and one case of acrylic foldable IOL with a two-plate loop design).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>Six patients, who had subluxation of the scleral-fixated posterior-chamber IOL due to single-knot dehiscence, underwent refixation of scleral-fixated IOL surgery using this technique. In all cases, successful repositioning with stable and central fixation of the IOLs was achieved. No intraoperative or postoperative complications were noted.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion:<\/jats:title>\n            <jats:p>Internal refixation with a girth-hitch suture is a relatively quick and convenient method for the management of a dislocated IOL haptic on one side.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/iae.0000000000004076","type":"journal-article","created":{"date-parts":[[2024,3,6]],"date-time":"2024-03-06T16:01:01Z","timestamp":1709740861000},"page":"2026-2029","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":2,"title":["A Modified Girth-Hitch Suture Technique to Rescue Single-Haptic Dislocation of Scleral-Fixated Intraocular Lenses"],"prefix":"10.1097","volume":"44","author":[{"given":"Mu\u0308cella","family":"Ar\u0131kan Yorgun","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yelda Y\u0131ld\u0131z","family":"Ta\u015f\u00e7\u0131","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Toklu","family":"Yasin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20250714","doi-asserted-by":"crossref","first-page":"1320","DOI":"10.1016\/j.jcrs.2004.12.060","article-title":"Late dislocation of scleral-sutured posterior chamber intraocular lenses","volume":"31","author":"Price","year":"2005","journal-title":"J Cataract Refract Surg"},{"key":"R2-20250714","doi-asserted-by":"crossref","first-page":"1118","DOI":"10.1016\/S0161-6420(02)01026-6","article-title":"Luxated intraocular lens fixation using intravitreal cow hitch (girth) knot","volume":"109","author":"Hanemoto","year":"2002","journal-title":"Ophthalmology"},{"key":"R3-20250714","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1097\/ICB.0000000000000483","article-title":"Scleral suture fixation technique for one-piece acrylic intraocular lens","volume":"12","author":"Leung","year":"2018","journal-title":"Retin Cases Brief Rep"},{"key":"R4-20250714","doi-asserted-by":"crossref","first-page":"265","DOI":"10.1016\/S0002-9394(00)00727-3","article-title":"Dislocated intraocular lens fixation using intraocular cowhitch knot","volume":"131","author":"Hanemoto","year":"2001","journal-title":"Am J Ophthalmol"},{"key":"R5-20250714","doi-asserted-by":"crossref","first-page":"676","DOI":"10.1016\/j.ajo.2004.05.014","article-title":"Surgical technique for repositioning subluxated previously scleral-fixated intraocular lenses","volume":"138","author":"Balta","year":"2004","journal-title":"Am J Ophthalmol"},{"key":"R6-20250714","doi-asserted-by":"crossref","first-page":"179","DOI":"10.3928\/23258160-20190301-08","article-title":"Modified cow-hitch suture for repositioning of subluxated scleral-fixated rigid intraocular lens","volume":"50","author":"Ma","year":"2019","journal-title":"Ophthalmic Surg Lasers Imaging Retina"},{"key":"R7-20250714","doi-asserted-by":"crossref","first-page":"1577","DOI":"10.1016\/S0886-3350(00)00476-4","article-title":"Repositioning a subluxated sutured intraocular lens in a vitrectomized eye","volume":"26","author":"Lee","year":"2000","journal-title":"J Cataract Refractive Surg"},{"key":"R8-20250714","doi-asserted-by":"crossref","first-page":"532","DOI":"10.1177\/112067210301300604","article-title":"Luxated intraocular lens fixation using anterior chamber slipknot of the haptic to the sclera: a simple procedure to fixate intraocular lens to the sclera","volume":"13","author":"Micelli Ferrari","year":"2003","journal-title":"Eur J Ophthalmol"},{"key":"R9-20250714","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1016\/j.jcrs.2009.07.048","article-title":"Modified Siepser sliding knot technique for scleral fixation of subluxated posterior chamber intraocular lens","volume":"36","author":"Ma","year":"2010","journal-title":"J Cataract Refract Surg"}],"container-title":["Retina"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/IAE.0000000000004076","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,7,14]],"date-time":"2025-07-14T20:00:12Z","timestamp":1752523212000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/IAE.0000000000004076"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,11]]},"references-count":9,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.1097\/iae.0000000000004076","relation":{},"ISSN":["0275-004X","1539-2864"],"issn-type":[{"value":"0275-004X","type":"print"},{"value":"1539-2864","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,11]]}}}