{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,7,14]],"date-time":"2025-07-14T20:40:07Z","timestamp":1752525607284,"version":"3.41.2"},"reference-count":13,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"11","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2024,11]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>The purpose of this study was to describe a modified technique for sutureless intrascleral intraocular lens fixation in patients without capsular support: the reverse 4-flanged technique.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>A 2.2-mm corneal incision was made for aphakic patients. The 6-0 polypropylene sutures were threaded through a 30-gauge needle outside the eye. An MDJ injector was employed to insert the intraocular lens into the eye. A suture-needle snare with 7-0 polypropylene was used to exteriorize the superior end of the sutures through the sclerotomy. The 6-0 polypropylene was heated with a cautery to create the flanges.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>Nine eyes of nine patients underwent the reverse 4-flanged technique. The median follow-up time was 182 days (range 174\u2013195). Best-corrected distance visual acuity improved from 20\/400 [hand movement\u201420\/33] to 20\/120 [20\/400\u201320\/21]. No vitreous hemorrhage, retinal detachment, endophthalmitis, intraocular lens luxation, or flange exposure was recorded during the follow-up.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion:<\/jats:title>\n            <jats:p>The reverse 4-flanged technique maintains the advantages of the original 4-flanged technique in terms of intraocular lens stability while reducing the incision size and surgical maneuvers performed inside the eye. This modification promises to be a reliable, safe, and relatively simple technique to correct aphakia in the absence of capsular support.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/iae.0000000000004101","type":"journal-article","created":{"date-parts":[[2024,4,2]],"date-time":"2024-04-02T17:00:55Z","timestamp":1712077255000},"page":"2030-2034","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Reverse 4-Flanged Technique for Intrascleral Fixation of a Foldable Hydrophobic Intraocular Lens in the Absence of Capsular Support Through a 2.2-mm Corneal Incision"],"prefix":"10.1097","volume":"44","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8846-8307","authenticated-orcid":false,"given":"Daniel","family":"Romero-Valero","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jose Juan","family":"Mart\u00ednez Toldos","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20250714","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1097\/ICU.0000000000000720","article-title":"Flanged fixation: Yamane technique and its application","volume":"32","author":"Yamane","year":"2021","journal-title":"Curr Opin Ophthalmol"},{"key":"R2-20250714","doi-asserted-by":"crossref","first-page":"1136","DOI":"10.1016\/j.ophtha.2017.03.036","article-title":"Flanged intrascleral intraocular lens fixation with double-needle technique","volume":"124","author":"Yamane","year":"2017","journal-title":"Ophthalmology"},{"key":"R3-20250714","doi-asserted-by":"crossref","first-page":"265","DOI":"10.1097\/j.jcrs.0000000000000310","article-title":"Scleral fixation of a 4-eyelet foldable intraocular lens in patients with aphakia using a 4-flanged technique","volume":"47","author":"Canabrava","year":"2021","journal-title":"J Cataract Refract Surg"},{"key":"R4-20250714","doi-asserted-by":"crossref","first-page":"E93","DOI":"10.1097\/j.jcrs.0000000000000800","article-title":"Suture-needle snare for scleral fixation","volume":"47","author":"Weinlander","year":"2021","journal-title":"J Cataract Refract Surg"},{"key":"R5-20250714","doi-asserted-by":"crossref","first-page":"1342","DOI":"10.1097\/j.jcrs.0000000000001024","article-title":"Attaining optimal flange size with 5-0 and 6-0 polypropylene sutures for scleral fixation","volume":"48","author":"Kronschl\u00e4ger","year":"2022","journal-title":"J Cataract Refract Surg"},{"key":"R6-20250714","doi-asserted-by":"crossref","first-page":"527","DOI":"10.1097\/ICO.0000000000002185","article-title":"Four-flanged intrascleral intraocular lens fixation technique: no flaps, no knots, no glue","volume":"39","author":"Canabrava","year":"2020","journal-title":"Cornea"},{"key":"R7-20250714","doi-asserted-by":"crossref","first-page":"565","DOI":"10.1097\/j.jcrs.0000000000001154","article-title":"Double-flanged polypropylene technique: 5-year results","volume":"49","author":"Canabrava","year":"2023","journal-title":"J Cataract Refract Surg"},{"key":"R8-20250714","doi-asserted-by":"crossref","first-page":"1387","DOI":"10.1097\/j.jcrs.0000000000000260","article-title":"Adjustable 6-0 polypropylene flanged technique for scleral fixation, part 1: primary fixation IOLs in aphakia, capsular stabilizing devices, and aniridia implants","volume":"46","author":"Assia","year":"2020","journal-title":"J Cataract Refract Surg"},{"key":"R9-20250714","doi-asserted-by":"crossref","first-page":"476","DOI":"10.1097\/j.jcrs.0000000000000474","article-title":"Intrascleral 4-flanged technique for in-the-bag intraocular lens subluxation","volume":"47","author":"Mahler","year":"2021","journal-title":"J Cataract Refract Surg."},{"key":"R10-20250714","doi-asserted-by":"crossref","first-page":"1227","DOI":"10.1097\/j.jcrs.0000000000000600","article-title":"Modification of intraocular lens insertion using 4-flanged fixation with a standard cartridge and a 2.4 mm corneal incision in eyes with no capsular support","volume":"47","author":"Mahler","year":"2021","journal-title":"J Cataract Refract Surg."},{"key":"R11-20250714","doi-asserted-by":"crossref","first-page":"e000157","DOI":"10.1136\/bmjophth-2018-000157","article-title":"Opacification of hydrophilic intraocular lenses associated with vitrectomy and injection of intraocular gas","volume":"3","author":"Marcovich","year":"2018","journal-title":"BMJ Open Ophthalmol"},{"key":"R12-20250714","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1016\/j.jcrs.2014.10.025","article-title":"Localized opacification of hydrophilic acrylic intraocular lenses after procedures using intracameral injection of air or gas","volume":"41","author":"Werner","year":"2015","journal-title":"J Cataract Refract Surg"},{"key":"R13-20250714","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1016\/j.ajo.2021.11.021","article-title":"Should we abandon hydrophilic intraocular lenses?","volume":"237","author":"Grzybowski","year":"2022","journal-title":"Am J Ophthalmol"}],"container-title":["Retina"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/IAE.0000000000004101","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,7,14]],"date-time":"2025-07-14T20:00:26Z","timestamp":1752523226000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/IAE.0000000000004101"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,11]]},"references-count":13,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.1097\/iae.0000000000004101","relation":{},"ISSN":["0275-004X","1539-2864"],"issn-type":[{"type":"print","value":"0275-004X"},{"type":"electronic","value":"1539-2864"}],"subject":[],"published":{"date-parts":[[2024,11]]}}}