{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,26]],"date-time":"2025-02-26T13:40:24Z","timestamp":1740577224230,"version":"3.38.0"},"reference-count":15,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","license":[{"start":{"date-parts":[[2025,2,17]],"date-time":"2025-02-17T00:00:00Z","timestamp":1739750400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,3]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>To present a new technique for lens explantation, involving intraocular lens (IOL) cleavage in the vitreous chamber using two forceps and successive removal from the anterior chamber.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>Retrospective monocentric analysis of 10 eyes affected by IOL subluxation\/luxation who underwent IOL explantation and 23-G vitrectomy. After separating the capsular bag rests from the IOL using the vitrectomy probe, serrated forceps were used to grab the IOL, while microscissors performed an \u201cinitiation\u201d cut at the midpoint of the lens plate. A second pair of serrated forceps grabbed the IOL plate on the other side. Then, the two forceps were slowly pulled one apart from the other, exerting a separative force perpendicular to the initiation cut and causing the IOL to cleave in two pieces. In case of asymmetric cleavage, a second cleavage was performed. The pieces of the IOL were then moved to the anterior chamber and removed through a clear corneal incision.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>Intraoperative mean IOL removal time was 14.1 \u00b1 6.5 minutes. The IOLs (seven 1-piece and three three-pieces IOLs) were successfully explanted with this technique in all patients. Overall, four cases underwent exclusive IOL explantation, and the eyes were left aphakic. Postoperatively, best corrected visual acuity improved in all patients at 1-week follow-up, and no intraoperative or postoperative adverse events were reported. Cornea was completely clear in every case since postoperative Day 1.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion:<\/jats:title>\n            <jats:p>Bimanual cleavage technique for IOL removal ensured safer IOL handling in the larger vitreous chamber and minimized the procedures to be performed in the anterior chamber.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/iae.0000000000004168","type":"journal-article","created":{"date-parts":[[2024,6,5]],"date-time":"2024-06-05T18:01:07Z","timestamp":1717610467000},"page":"574-578","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["An Alternative Technique For Intraocular Lens Removal: Bimanual Cleavage In The Vitreous Chamber"],"prefix":"10.1097","volume":"45","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2979-1638","authenticated-orcid":false,"given":"Matteo Mario","family":"Carl\u00e0","sequence":"first","affiliation":[{"name":"Ophthalmology Department, Catholic University \u201cSacro Cuore\u201d, Rome, Italy;"},{"name":"Ophthalmology Department, \u201cFondazione Policlinico Universitario A. Gemelli, IRCCS\u201d, Rome, Italy; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Carlos","family":"Mateo","sequence":"additional","affiliation":[{"name":"Instituto de Microcirugia Ocular, Barcelona, Spain."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2025,2,17]]},"reference":[{"key":"R1-20250226","doi-asserted-by":"crossref","first-page":"942","DOI":"10.1097\/j.jcrs.0000000000000605","article-title":"Late in-the-bag intraocular lens dislocation","volume":"47","author":"Kristianslund","year":"2021","journal-title":"J Cataract Refract Surg"},{"key":"R2-20250226","doi-asserted-by":"crossref","first-page":"12877","DOI":"10.1038\/s41598-019-49030-2","article-title":"Incidence of intraocular lens exchange after cataract surgery","volume":"9","author":"Abdalla Elsayed","year":"2019","journal-title":"Sci Rep"},{"key":"R3-20250226","doi-asserted-by":"crossref","first-page":"504","DOI":"10.3928\/23258160-20190806-05","article-title":"Indications and outcomes for the removal of intraocular lens implants in a retinal surgery practice","volume":"50","author":"Patel","year":"2019","journal-title":"Ophthalmic Surg Lasers Imaging Retina"},{"key":"R4-20250226","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1016\/j.ophtha.2013.08.043","article-title":"Sutureless 27-gauge needle-guided intrascleral intraocular lens implantation with lamellar scleral dissection","volume":"121","author":"Yamane","year":"2014","journal-title":"Ophthalmology"},{"key":"R5-20250226","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1016\/j.jcrs.2013.11.003","article-title":"Simplified and safe method of sutureless intrascleral posterior chamber intraocular lens fixation: Y-fixation technique","volume":"40","author":"Ohta","year":"2014","journal-title":"J Cataract Refract Surg"},{"key":"R6-20250226","doi-asserted-by":"crossref","first-page":"1428","DOI":"10.4103\/ijo.IJO_664_17","article-title":"A simple technique of intraocular lenses explantation for single-piece foldable lenses","volume":"65","author":"Bhaumik","year":"2017","journal-title":"Indian J Ophthalmol"},{"key":"R7-20250226","first-page":"925","article-title":"Intraocular lens exchange-removing the optic intact","volume":"9","author":"Lee","year":"2016","journal-title":"Int J Ophthalmol"},{"key":"R8-20250226","doi-asserted-by":"crossref","first-page":"499","DOI":"10.3928\/1081597X-20120531-01","article-title":"Intraocular lens explantation technique for one-piece acrylic lenses","volume":"28","author":"Henderson","year":"2012","journal-title":"J Refract Surg"},{"key":"R9-20250226","doi-asserted-by":"crossref","first-page":"1217","DOI":"10.1016\/S0886-3350(02)01357-3","article-title":"Complications and clinical outcomes of intraocular lens exchange in patients with calcified hydrogel lenses","volume":"28","author":"Yu","year":"2002","journal-title":"J Cataract Refract Surg"},{"key":"R10-20250226","doi-asserted-by":"crossref","first-page":"254","DOI":"10.1055\/s-0028-1109302","article-title":"Hydrogel intraocular lens exchange: five-year experience","volume":"226","author":"Theoulakis","year":"2009","journal-title":"Klin Monbl Augenheilkd"},{"key":"R11-20250226","doi-asserted-by":"crossref","first-page":"1340","DOI":"10.1016\/j.jcrs.2006.02.062","article-title":"Hydrophilic acrylic intraocular lens exchange: five-year experience","volume":"32","author":"Gashau","year":"2006","journal-title":"J Cataract Refract Surg"},{"key":"R12-20250226","doi-asserted-by":"crossref","first-page":"e70","DOI":"10.1097\/j.jcrs.0000000000000695","article-title":"Intraocular lens extraction using the cartridge pull-through technique","volume":"47","author":"Fukuoka","year":"2021","journal-title":"J Cataract Refract Surg"},{"key":"R13-20250226","doi-asserted-by":"crossref","first-page":"1072","DOI":"10.1097\/j.jcrs.0000000000000161","article-title":"Twist and out intraocular lens removal","volume":"46","author":"Pandit","year":"2020","journal-title":"J Cataract Refract Surg"},{"key":"R14-20250226","doi-asserted-by":"crossref","first-page":"969","DOI":"10.1016\/j.ophtha.2006.09.017","article-title":"Possible predisposing factors for in-the-bag and out-of-the-bag intraocular lens dislocation and outcomes of intraocular lens exchange surgery","volume":"114","author":"Hayashi","year":"2007","journal-title":"Ophthalmology"},{"key":"R15-20250226","first-page":"372","article-title":"Intraocular lens explantation after cataract surgery: indications, results, and explantation techniques","volume":"6","author":"Fernandez-Buenaga","year":"2017","journal-title":"Asia Pac J Ophthalmol (Phila)"}],"container-title":["Retina"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/IAE.0000000000004168","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,2,26]],"date-time":"2025-02-26T13:00:51Z","timestamp":1740574851000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/IAE.0000000000004168"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,2,17]]},"references-count":15,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/iae.0000000000004168","relation":{},"ISSN":["0275-004X","1539-2864"],"issn-type":[{"type":"print","value":"0275-004X"},{"type":"electronic","value":"1539-2864"}],"subject":[],"published":{"date-parts":[[2025,2,17]]}}}