{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,17]],"date-time":"2026-02-17T14:00:38Z","timestamp":1771336838847,"version":"3.50.1"},"reference-count":28,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"10","license":[{"start":{"date-parts":[[2024,9,12]],"date-time":"2024-09-12T00:00:00Z","timestamp":1726099200000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2024,10]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>To investigate the anatomical changes and surgical outcomes of hemi-temporal internal limiting membrane (ILM) peeling and conventional ILM peeling for idiopathic macular hole (MH).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>This randomized controlled trial was conducted at 3 centers and included 50 participants with MHs of &lt;400 <jats:italic toggle=\"yes\">\u00b5<\/jats:italic>m in minimum diameter for a duration of &lt;6 months. All participants had undergone vitrectomy with either hemi-temporal ILM peeling (Hemi group) or 360\u00b0 ILM peeling (360\u00b0 group) with an injection of 5% sulfur hexafluoride gas, with or without simultaneous cataract surgery, from July 2017 to January 2021. The rate of MH closure and distance of retinal migration were examined.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>Of 50 eyes randomized in the 3 centers, the Hemi group comprised 23 eyes, the 360\u00b0 group 23 eyes, and 4 eyes were eliminated from final analysis. There was a significantly higher rate of primary MH closure in the 360\u00b0 group (Hemi group: 73.9% vs. 360\u00b0 group: 100%, <jats:italic toggle=\"yes\">P<\/jats:italic> = 0.009). Retinal migration to the optic disk on the nasal side was significantly shorter in the Hemi group at 1, 3, and 6 months postoperatively than in the 360\u00b0 group. There was no significant difference between the two groups in retinal migration to the optic disk on the temporal side.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion:<\/jats:title>\n            <jats:p>Nasal retinal migration in patients who underwent the hemi-temporal ILM peeling method was significantly less than in those who underwent the 360\u00b0 ILM peeling method. However, less nasal retinal migration did not contribute to the MH closure rate.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/iae.0000000000004196","type":"journal-article","created":{"date-parts":[[2024,6,21]],"date-time":"2024-06-21T21:00:10Z","timestamp":1719003610000},"page":"1793-1799","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":2,"title":["RETINAL MIGRATION AND SURGICAL OUTCOME AFTER HEMI-TEMPORAL INTERNAL LIMITING MEMBRANE PEELING VERSUS CONVENTIONAL PEELING FOR MACULAR HOLE"],"prefix":"10.1097","volume":"44","author":[{"given":"Tatsuya","family":"Jujo","sequence":"first","affiliation":[{"name":"Department of Ophthalmology, St. Marianna University School of Medicine, Kawasaki, Japan;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Akira","family":"Shiono","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, St. Marianna University School of Medicine, Kawasaki, Japan;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Keiji","family":"Sato","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, St. Marianna University School of Medicine, Kawasaki, Japan;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Reio","family":"Sekine","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, St. Marianna University School of Medicine, Kawasaki, Japan;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Naoto","family":"Uchiyama","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, St. Marianna University School of Medicine, Kawasaki, Japan;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kota","family":"Kakehashi","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, St. Marianna University School of Medicine, Kawasaki, Japan;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Akiko","family":"Endo","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, St. Marianna University School of Medicine, Kawasaki, Japan;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Akira","family":"Arakawa","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, St. Marianna University, Yokohama City Seibu Hospital; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Youichiro","family":"Shinkai","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Kyoto Prefectural University of Medicine, Kyoto, Japan."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yasushi","family":"Kitaoka","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, St. Marianna University School of Medicine, Kawasaki, Japan;"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2024,9,12]]},"reference":[{"key":"R1-20250605","doi-asserted-by":"crossref","first-page":"744","DOI":"10.1001\/archopht.117.6.744","article-title":"Macular hole formation: new data provided by optical coherence tomography","volume":"117","author":"Gaudric","year":"1999","journal-title":"Arch Ophthalmol"},{"key":"R2-20250605","doi-asserted-by":"crossref","first-page":"654","DOI":"10.1001\/archopht.1991.01080050068031","article-title":"Vitreous surgery for idiopathic macular holes. Results of a pilot study","volume":"109","author":"Kelly","year":"1991","journal-title":"Arch Ophthalmol"},{"key":"R3-20250605","doi-asserted-by":"crossref","first-page":"1939","DOI":"10.1016\/S0161-6420(00)00331-6","article-title":"Macular hole surgery with and without internal limiting membrane peeling","volume":"107","author":"Brooks","year":"2000","journal-title":"Ophthalmology"},{"key":"R4-20250605","doi-asserted-by":"crossref","first-page":"971","DOI":"10.1016\/j.ajo.2014.01.026","article-title":"Retinal displacement toward optic disc after internal limiting membrane peeling for idiopathic macular hole","volume":"157","author":"Ishida","year":"2014","journal-title":"Am J Ophthalmol"},{"key":"R5-20250605","doi-asserted-by":"crossref","first-page":"629","DOI":"10.1167\/iovs.12-10907","article-title":"Macular migration toward the optic disc after inner limiting membrane peeling for diabetic macular edema","volume":"54","author":"Yoshikawa","year":"2013","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R6-20250605","doi-asserted-by":"crossref","first-page":"1779","DOI":"10.1097\/IAE.0000000000002215","article-title":"Hemi-temporal internal limiting membrane peeling is as effective and safe as conventional full peeling for macular hole surgery","volume":"39","author":"Shiono","year":"2019","journal-title":"Retina"},{"key":"R7-20250605","first-page":"631","article-title":"Brilliant blue G selectively stains the internal limiting membrane\/brilliant blue G-assisted membrane peeling","volume":"26","author":"Enaida","year":"2006","journal-title":"Retina"},{"key":"R8-20250605","doi-asserted-by":"crossref","first-page":"695","DOI":"10.1097\/IAE.0000000000000768","article-title":"Measurement of retinal displacement and metamorphopsia after epiretinal membrane or macular hole surgery","volume":"36","author":"Rodrigues","year":"2016","journal-title":"Retina"},{"key":"R9-20250605","doi-asserted-by":"crossref","first-page":"1408","DOI":"10.18240\/ijo.2021.09.17","article-title":"Displacement of the retina after idiopathic macular hole surgery with different internal limiting membrane peeling patterns","volume":"14","author":"Liu","year":"2021","journal-title":"Int J Ophthalmol"},{"key":"R10-20250605","doi-asserted-by":"crossref","first-page":"871","DOI":"10.1038\/eye.2013.99","article-title":"Displacement of foveal area toward optic disc after macular hole surgery with internal limiting membrane peeling","volume":"27","author":"Kawano","year":"2013","journal-title":"Eye (Lond)"},{"key":"R11-20250605","doi-asserted-by":"crossref","first-page":"1512","DOI":"10.1038\/s41433-018-0107-2","article-title":"Non-inverted pedicle internal limiting membrane transposition for large macular holes","volume":"32","author":"Hu","year":"2018","journal-title":"Eye (Lond)"},{"key":"R12-20250605","doi-asserted-by":"crossref","first-page":"2018","DOI":"10.1016\/j.ophtha.2010.02.011","article-title":"Inverted internal limiting membrane flap technique for large macular holes","volume":"117","author":"Michalewska","year":"2010","journal-title":"Ophthalmology"},{"key":"R13-20250605","doi-asserted-by":"crossref","first-page":"1255","DOI":"10.3109\/02713683.2013.811261","article-title":"Macular slippage after macular hole surgery with internal limiting membrane peeling","volume":"38","author":"Nakagomi","year":"2013","journal-title":"Curr Eye Res"},{"key":"R14-20250605","doi-asserted-by":"crossref","first-page":"754","DOI":"10.1038\/eye.2011.48","article-title":"Improvement of horizontal macular contraction after surgical removal of epiretinal membranes","volume":"25","author":"Yang","year":"2011","journal-title":"Eye (Lond)"},{"key":"R15-20250605","doi-asserted-by":"crossref","first-page":"1014","DOI":"10.1016\/j.ajo.2013.01.021","article-title":"Displacement of the retina and its recovery after vitrectomy in idiopathic epiretinal membrane","volume":"155","author":"Nitta","year":"2013","journal-title":"Am J Ophthalmol"},{"key":"R16-20250605","doi-asserted-by":"crossref","first-page":"2897","DOI":"10.1111\/j.1742-4658.2007.05823.x","article-title":"Biomechanical properties of native basement membranes","volume":"274","author":"Candiello","year":"2007","journal-title":"FEBS J"},{"key":"R17-20250605","doi-asserted-by":"crossref","first-page":"965","DOI":"10.1097\/01.iae.0000250001.45661.95","article-title":"Biomechanical significance of the human internal limiting lamina","volume":"26","author":"Wollensak","year":"2006","journal-title":"Retina"},{"key":"R18-20250605","doi-asserted-by":"crossref","first-page":"319","DOI":"10.1038\/nrn2631","article-title":"Microtubule assembly, organization and dynamics in axons and dendrites","volume":"10","author":"Conde","year":"2009","journal-title":"Nat Rev Neurosci"},{"key":"R19-20250605","doi-asserted-by":"crossref","first-page":"680","DOI":"10.1136\/bjo.82.6.680","article-title":"Axon deviation in the human lamina cribrosa","volume":"82","author":"Morgan","year":"1998","journal-title":"Br J Ophthalmol"},{"key":"R20-20250605","doi-asserted-by":"crossref","first-page":"1005","DOI":"10.1136\/bjo.2008.151266","article-title":"Value of internal limiting membrane peeling in surgery for idiopathic macular hole stage 2 and 3: a randomised clinical trial","volume":"93","author":"Christensen","year":"2009","journal-title":"Br J Ophthalmol"},{"key":"R21-20250605","doi-asserted-by":"crossref","first-page":"1586","DOI":"10.1167\/iovs.10-6287","article-title":"Internal limiting membrane peeling versus no peeling for idiopathic full-thickness macular hole: a pragmatic randomized controlled trial","volume":"52","author":"Lois","year":"2011","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R22-20250605","doi-asserted-by":"crossref","first-page":"649","DOI":"10.1016\/j.ophtha.2013.10.020","article-title":"Vitrectomy with internal limiting membrane peeling versus no peeling for idiopathic full-thickness macular hole","volume":"121","author":"Spiteri Cornish","year":"2014","journal-title":"Ophthalmology"},{"key":"R23-20250605","doi-asserted-by":"crossref","first-page":"1998","DOI":"10.1016\/j.ophtha.2013.06.001","article-title":"No face-down positioning and broad internal limiting membrane peeling in the surgical repair of idiopathic macular holes","volume":"120","author":"Iezzi","year":"2013","journal-title":"Ophthalmology"},{"key":"R24-20250605","doi-asserted-by":"crossref","first-page":"179","DOI":"10.1097\/00006982-199717030-00001","article-title":"Macular hole surgery without face-down positioning: a pilot study","volume":"17","author":"Tornambe","year":"1997","journal-title":"Retina"},{"key":"R25-20250605","doi-asserted-by":"crossref","first-page":"373","DOI":"10.1097\/00006982-199616050-00002","article-title":"Intraocular tamponade duration and success of macular hole surgery","volume":"16","author":"Thompson","year":"1996","journal-title":"Retina"},{"key":"R26-20250605","doi-asserted-by":"crossref","first-page":"1514","DOI":"10.1016\/S0161-6420(02)01093-X","article-title":"Effects of preoperative and postoperative epiretinal membranes on macular hole closure and visual restoration","volume":"109","author":"Cheng","year":"2002","journal-title":"Ophthalmology"},{"key":"R27-20250605","doi-asserted-by":"crossref","first-page":"395","DOI":"10.1076\/ceyr.27.6.395.18189","article-title":"Ultrastructure of the vitreoretinal interface following the removal of the internal limiting membrane using indocyanine green","volume":"27","author":"Nakamura","year":"2003","journal-title":"Curr Eye Res"},{"key":"R28-20250605","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1016\/j.jcjo.2016.07.009","article-title":"Spectral domain optical coherence tomography-guided versus 1-week facedown-posturing after macular hole surgery","volume":"52","author":"Xu","year":"2017","journal-title":"Can J Ophthalmol"}],"container-title":["Retina"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/IAE.0000000000004196","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,5]],"date-time":"2025-06-05T17:02:48Z","timestamp":1749142968000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/IAE.0000000000004196"}},"subtitle":["A Multicenter, Randomized, Controlled Trial"],"short-title":[],"issued":{"date-parts":[[2024,9,12]]},"references-count":28,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.1097\/iae.0000000000004196","relation":{},"ISSN":["0275-004X"],"issn-type":[{"value":"0275-004X","type":"print"}],"subject":[],"published":{"date-parts":[[2024,9,12]]}}}