{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,24]],"date-time":"2026-09-24T21:39:08Z","timestamp":1790285948512,"version":"4.1.0"},"reference-count":26,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,3]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>The aim of the study is to explore the effectiveness of using monochrome mode with Brilliant Blue G during vitrectomy surgery with the NGENUITY 3D Visualization System.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>Vitrectomy cases involving BBG-stained internal limiting membrane peeling with the NGENUITY 3D Visualization System (Alcon Laboratories, Inc.) at Juntendo University Urayasu Hospital from October 2022 to February 2023 were selected. The contrast ratios between peeled and stained internal limiting membrane areas under three settings were assessed: normal, yellow, and monochrome. In the monochrome setting, a yellow hue was used with zero saturation, while the Friedman test compared these ratios.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>Nineteen patients (19 eyes; 7 males, 12 females; average age 68.5 \u00b1 10.3 years) with retinal conditions such as epiretinal membrane (n = 11), macular hole (n = 4), macular traction syndrome (n = 3), and retinoschisis (n = 1) were included. We obtained contrast ratios of 1.57 \u00b1 0.21 (normal), 1.60 \u00b1 0.21 (yellow), and 1.92 \u00b1 0.29 (monochrome). The monochrome setting showed significantly higher contrast than that shown by the normal and yellow settings (<jats:italic toggle=\"yes\">P<\/jats:italic> = 0.0001, <jats:italic toggle=\"yes\">P<\/jats:italic> = 0.0005), with no difference between the normal and yellow settings (<jats:italic toggle=\"yes\">P<\/jats:italic> = 0.903).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion:<\/jats:title>\n            <jats:p>Monochrome mode in NGENUITY with Brilliant Blue G potentially enhances contrast and increases visibility during internal limiting membrane peeling.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/iae.0000000000004330","type":"journal-article","created":{"date-parts":[[2024,11,21]],"date-time":"2024-11-21T21:01:14Z","timestamp":1732222874000},"page":"486-490","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":4,"title":["INCREASING THE VISIBILITY DURING INTERNAL LIMITING MEMBRANE PEELING IN VITRECTOMY SURGERY"],"prefix":"10.1097","volume":"45","author":[{"given":"Keiji","family":"Matsumoto","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yoshihito","family":"Sakanishi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tatsuya","family":"Fujii","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ayumi","family":"Usui-Ouchi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Toshiro","family":"Sakuma","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nobuyuki","family":"Ebihara","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20250226","doi-asserted-by":"crossref","first-page":"1208","DOI":"10.4103\/ijo.IJO_2028_20","article-title":"Vitrectomy without encircling band for rhegmatogenous retinal detachment with inferior break utilizing 3D heads up viewing system","volume":"69","author":"Narde","year":"2021","journal-title":"Indian J Ophthalmol"},{"key":"R2-20250226","doi-asserted-by":"crossref","first-page":"432","DOI":"10.1136\/bjophthalmol-2019-314123","article-title":"Utility of digitally assisted vitreoretinal surgery systems (DAVS) for high-volume vitreoretinal surgery centre: a pilot study","volume":"104","author":"Babu","year":"2020","journal-title":"Br J Ophthalmol"},{"key":"R3-20250226","doi-asserted-by":"crossref","first-page":"1768","DOI":"10.1097\/IAE.0000000000002236","article-title":"Resolution, depth of field, and physician satisfaction during digitally assisted vitreoretinal surgery","volume":"39","author":"Freeman","year":"2019","journal-title":"Retina"},{"key":"R4-20250226","doi-asserted-by":"crossref","first-page":"746","DOI":"10.1002\/micr.1920161109","article-title":"Microsurgery without a microscope: laboratory evaluation of a three-dimensional on-screen microsurgery system","volume":"16","author":"Franken","year":"1995","journal-title":"Microsurgery"},{"key":"R5-20250226","doi-asserted-by":"crossref","first-page":"102","DOI":"10.1080\/02713683.2018.1526305","article-title":"The preliminary experiences with three-dimensional heads-up display viewing system for vitreoretinal surgery under various status","volume":"44","author":"Zhang","year":"2019","journal-title":"Curr Eye Res"},{"key":"R6-20250226","doi-asserted-by":"crossref","first-page":"115","DOI":"10.4103\/sni.sni_36_18","article-title":"Microvascular anastomosis under 3D exoscope or endoscope magnification: a proof-of-concept study","volume":"9","author":"Belykh","year":"2018","journal-title":"Surg Neurol Int"},{"key":"R7-20250226","doi-asserted-by":"crossref","first-page":"1087","DOI":"10.1007\/s004649901179","article-title":"The effect of a second-generation 3D endoscope on the laparoscopic precision of novices and experienced surgeons","volume":"13","author":"Taffinder","year":"1999","journal-title":"Surg Endosc"},{"key":"R8-20250226","doi-asserted-by":"crossref","first-page":"816","DOI":"10.1089\/end.2014.0759","article-title":"A comparative study of distinct ocular symptoms after performing laparoscopic surgical tasks using a three-dimensional surgical imaging system and a conventional two-dimensional surgical imaging system","volume":"29","author":"Zhou","year":"2015","journal-title":"J Endourol"},{"key":"R9-20250226","doi-asserted-by":"crossref","first-page":"644","DOI":"10.1016\/j.jsurg.2016.12.002","article-title":"Skills comparison in pediatric residents using a 2-Dimensional versus a 3-Dimensional high- definition camera in a pediatric laparoscopic simulator","volume":"74","author":"Guan\u00e0","year":"2017","journal-title":"J Surg Educ"},{"key":"R10-20250226","doi-asserted-by":"crossref","first-page":"e717","DOI":"10.1097\/GOX.0000000000000727","article-title":"Heads-up 3D microscopy: an ergonomic and educational approach to microsurgery","volume":"4","author":"Mendez","year":"2016","journal-title":"Plast Reconstr Surg Glob Open"},{"key":"R11-20250226","doi-asserted-by":"crossref","first-page":"2109","DOI":"10.1097\/IAE.0000000000003442","article-title":"Use of the three-dimensional viewing system and microscope tilting to extend the peripheral retinal view","volume":"43","author":"Sandali","year":"2023","journal-title":"Retina"},{"key":"R12-20250226","doi-asserted-by":"crossref","first-page":"1116","DOI":"10.1001\/archopht.118.8.1116","article-title":"Staining of internal limiting membrane in macular hole surgery","volume":"118","author":"Kadonosono","year":"2000","journal-title":"Arch Ophthalmol"},{"key":"R13-20250226","doi-asserted-by":"crossref","first-page":"836","DOI":"10.1016\/S0002-9394(02)01816-0","article-title":"Indocyanine green-assisted peeling of the internal limiting membrane in macular hole surgery affects visual outcome: a clinicopathologic correlation","volume":"134","author":"Haritoglou","year":"2002","journal-title":"Am J Ophthalmol"},{"key":"R14-20250226","doi-asserted-by":"crossref","first-page":"178","DOI":"10.1016\/S0002-9394(01)00976-X","article-title":"Indocyanine green staining and removal of internal limiting membrane in macular hole surgery: histology and outcome","volume":"132","author":"Kwok","year":"2001","journal-title":"Am J Ophthalmol"},{"key":"R15-20250226","doi-asserted-by":"crossref","first-page":"2609","DOI":"10.1016\/j.ophtha.2012.06.048","article-title":"Comparison of vitrectomy with brilliant blue G or indocyanine green on retinal microstructure and function of eyes with macular hole","volume":"119","author":"Baba","year":"2012","journal-title":"Ophthalmology"},{"key":"R16-20250226","doi-asserted-by":"crossref","first-page":"4426","DOI":"10.1167\/iovs.07-0358","article-title":"Intracellular events in retinal glial cells exposed to ICG and BBG","volume":"48","author":"Kawahara","year":"2007","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R17-20250226","doi-asserted-by":"crossref","first-page":"4056","DOI":"10.3390\/jcm11144056","article-title":"Use of black-and-white digital filters to optimize visualization in cataract surgery","volume":"11","author":"Sandali","year":"2022","journal-title":"J Clin Med"},{"key":"R19-20250226","doi-asserted-by":"crossref","first-page":"812","DOI":"10.1097\/IAE.0b013e3182807629","article-title":"Internal limiting membrane contrast after staining with indocyanine green and brilliant blue G during macular surgery","volume":"33","author":"Kadonosono","year":"2013","journal-title":"Retina"},{"key":"R20-20250226","first-page":"631","article-title":"Brilliant blue G selectively stains the internal limiting membrane\/brilliant blue G-assisted membrane peeling","volume":"26","author":"Enaida","year":"2006","journal-title":"Retina"},{"key":"R21-20250226","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1007\/s10384-023-01042-2","article-title":"Color enhancement and achromatization to increase the visibility of indocyanine green-stained internal limiting membrane during digitally assisted vitreoretinal surgery","volume":"68","author":"Imai","year":"2024","journal-title":"Jpn J Ophthalmol"},{"key":"R22-20250226","doi-asserted-by":"crossref","first-page":"6404","DOI":"10.3390\/jcm11216404","article-title":"Electroretinographic assessments of macular function after brilliant blue G staining for inner limiting membrane peeling","volume":"11","author":"Terauchi","year":"2022","journal-title":"J Clin Med"},{"key":"R23-20250226","doi-asserted-by":"crossref","first-page":"2752","DOI":"10.4103\/ijo.IJO_2816_20","article-title":"Evaluation of retinal functional changes after macular hole surgery using heavy brilliant blue G dye for internal limiting membrane staining: a prospective, single blind, randomized controlled trial","volume":"69","author":"Kannan","year":"2021","journal-title":"Indian J Ophthalmol"},{"key":"R24-20250226","doi-asserted-by":"crossref","first-page":"534","DOI":"10.1007\/s10384-022-00942-z","article-title":"Outer retinal microstructure and visual function after macular hole surgery with and without Brilliant Blue G","volume":"66","author":"Komiya","year":"2022","journal-title":"Jpn J Ophthalmol"},{"key":"R25-20250226","doi-asserted-by":"crossref","first-page":"689","DOI":"10.1007\/s10384-021-00851-7","article-title":"Inner retinal structure and visual function after idiopathic epiretinal membrane surgery with and without brilliant blue G","volume":"65","author":"Takeyama","year":"2021","journal-title":"Jpn J Ophthalmol"},{"key":"R26-20250226","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1080\/08820538.2021.1928717","article-title":"Brilliant Blue G toxicity in macular hole surgeries: a report on combined phototoxicity and dye-induced macular damage","volume":"37","author":"Soni","year":"2022","journal-title":"Semin Ophthalmol"},{"key":"R27-20250226","doi-asserted-by":"crossref","first-page":"1265","DOI":"10.1080\/02713683.2020.1737136","article-title":"Clinical study on the initial experiences of French vitreoretinal surgeons with heads-up surgery","volume":"45","author":"Pal\u00e1cios","year":"2020","journal-title":"Curr Eye Res"}],"container-title":["Retina"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/IAE.0000000000004330","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,2,26]],"date-time":"2025-02-26T13:03:00Z","timestamp":1740574980000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/IAE.0000000000004330"}},"subtitle":["Evaluation of Monochrome Mode with Brilliant Blue G Staining Using the NGENUITY 3D Visualization System"],"short-title":[],"issued":{"date-parts":[[2025,3]]},"references-count":26,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/iae.0000000000004330","relation":{},"ISSN":["0275-004X","1539-2864"],"issn-type":[{"value":"0275-004X","type":"print"},{"value":"1539-2864","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,3]]}}}