{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,19]],"date-time":"2026-06-19T11:59:13Z","timestamp":1781870353608,"version":"3.54.5"},"reference-count":28,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","funder":[{"DOI":"10.13039\/501100014820","name":"Li Ka Shing Faculty of Medicine, University of Hong Kong","doi-asserted-by":"crossref","award":["Start-up Fund"],"award-info":[{"award-number":["Start-up Fund"]}],"id":[{"id":"10.13039\/501100014820","id-type":"DOI","asserted-by":"crossref"}]},{"DOI":"10.13039\/501100003803","name":"University of Hong Kong","doi-asserted-by":"crossref","award":["General Research Fund (17105723)"],"award-info":[{"award-number":["General Research Fund (17105723)"]}],"id":[{"id":"10.13039\/501100003803","id-type":"DOI","asserted-by":"crossref"}]},{"DOI":"10.13039\/501100003803","name":"University of Hong Kong","doi-asserted-by":"crossref","award":["Small Equipment Fund"],"award-info":[{"award-number":["Small Equipment Fund"]}],"id":[{"id":"10.13039\/501100003803","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,4]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>To validate the presence of residual nonemulsified silicone oil (SO) after conventional surgical removal techniques used in vitreoretinal surgery and provide insights for optimizing surgical parameters and reducing subsequent emulsification-related complications.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>The two surgical steps of repeated fluid\u2013air exchange, including aspiration and infusion, were simulated in vitro to investigate their effectiveness in removing residual nonemulsified SO under various clinical settings. Aspiration was performed at three different positions about the SO interface (i.e., within the SO phase, at the SO\/balanced salt solution interface, and within the balanced salt solution phase) with a 25-gauge probe. An infusion was positioned near the SO\/balanced salt solution interface with an intraoperatively standardized flow rate (5 mL\/minute). In a further ex vivo study, the volume of residual nonemulsified SO (collected by Dichloromethane) was quantified by Flourier-transform infrared spectroscopy in both repeated fluid\u2013air exchange and passive drainage groups.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>In the in vitro model, regardless of which position a 25-gauge probe was located, residual nonemulsified SO could not be effectively removed even under high aspiration levels (<jats:italic toggle=\"yes\">P<\/jats:italic> &gt; 0.05). Continuous balanced salt solution infusion led to small SO droplet formation. Residual SO in both nonemulsified and emulsified forms was observed in the ex vivo model subjected to repeated fluid\u2013air exchange. The volume of residual nonemulsified SO was quantified, ranging from 2.75 to 24.71 <jats:italic toggle=\"yes\">\u00b5<\/jats:italic>L, without significant difference among experimental groups (<jats:italic toggle=\"yes\">P<\/jats:italic> &gt; 0.05).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion:<\/jats:title>\n            <jats:p>Complete residual nonemulsified SO removal was technically challenging by conventional surgical techniques. This residual nonemulsified SO could serve as a source of ongoing SO emulsification.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/iae.0000000000004353","type":"journal-article","created":{"date-parts":[[2024,12,9]],"date-time":"2024-12-09T22:00:25Z","timestamp":1733781625000},"page":"630-638","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":2,"title":["RESIDUAL SILICONE OIL DOES APPEAR AFTER CONVENTIONAL REMOVAL AND CONTRIBUTES TO POSTOPERATIVE EMULSIFICATION"],"prefix":"10.1097","volume":"45","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3258-7742","authenticated-orcid":false,"given":"Ying","family":"Chen","sequence":"first","affiliation":[{"name":"Department of Ophthalmology, The University of Hong Kong, Hong Kong SAR, China;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kenneth Kai Wang","family":"Li","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, The University of Hong Kong, Hong Kong SAR, China;"},{"name":"Department of Ophthalmology, United Christian Hospital, Hong Kong SAR, China;"},{"name":"Department of Ophthalmology, Tseung Kwan O Hospital, Hong Kong SAR, China;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David H.","family":"Steel","sequence":"additional","affiliation":[{"name":"Sunderland Eye Infirmary, Sunderland, United Kingdom;"},{"name":"Bioscience Institute, Newcastle University, Newcastle upon Tyne, United Kingdom; and"},{"name":"Department of Eye and Vision Science, University of Liverpool, Liverpool, United Kingdom."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1044-2668","authenticated-orcid":false,"given":"Yau Kei","family":"Chan","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, The University of Hong Kong, Hong Kong SAR, China;"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20250331","doi-asserted-by":"crossref","first-page":"870","DOI":"10.1016\/S0161-6420(88)33080-0","article-title":"Complications associated with the use of silicone oil in 150 eyes after retina-vitreous surgery","volume":"95","author":"Federman","year":"1988","journal-title":"Ophthalmology"},{"key":"R2-20250331","doi-asserted-by":"crossref","first-page":"201","DOI":"10.1111\/aos.12212","article-title":"Neuronal complications of intravitreal silicone oil: an updated review","volume":"92","author":"Grzybowski","year":"2014","journal-title":"Acta Ophthalmol"},{"key":"R3-20250331","doi-asserted-by":"crossref","first-page":"9721","DOI":"10.1167\/iovs.11-8586","article-title":"Emulsification of silicone oil and eye movements","volume":"52","author":"Chan","year":"2011","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R4-20250331","doi-asserted-by":"crossref","first-page":"240","DOI":"10.1111\/aos.14604","article-title":"Silicone oil in vitreoretinal surgery: indications, complications, new developments and alternative long-term tamponade agents","volume":"99","author":"Chen","year":"2021","journal-title":"Acta Ophthalmologica"},{"key":"R5-20250331","doi-asserted-by":"crossref","first-page":"1671","DOI":"10.1007\/s00417-014-2866-1","article-title":"Quantifying silicone oil emulsification in patients: are we only seeing the tip of the iceberg?","volume":"253","author":"Chan","year":"2015","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"R6-20250331","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1007\/BF00951805","article-title":"Fluid air exchange in vitreo retinal surgery","volume":"18","author":"Berrod","year":"1994","journal-title":"Int Ophthalmol"},{"key":"R7-20250331","doi-asserted-by":"crossref","first-page":"88","DOI":"10.1007\/BF00172269","article-title":"Emulsification of silicone oils with specific physicochemical characteristics","volume":"229","author":"Heidenkummer","year":"1991","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"R8-20250331","first-page":"647","article-title":"Factors contributing to the emulsification of intraocular silicone and fluorosilicone oils","volume":"31","author":"Nakamura","year":"1990","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R9-20250331","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1159\/000328207","article-title":"Vitrectomy fluidics","volume":"226","author":"Steel","year":"2011","journal-title":"Ophthalmologica"},{"key":"R10-20250331","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1097\/00006982-198300320-00013","article-title":"New instrumentation for fluid-air exchange","volume":"3","author":"Brucker","year":"1983","journal-title":"Retina"},{"key":"R11-20250331","doi-asserted-by":"crossref","first-page":"597","DOI":"10.1097\/00006982-200210000-00010","article-title":"Comparison of silicone oil removal with passive drainage alone versus passive drainage combined with air-fluid exchange","volume":"22","author":"Dabil","year":"2002","journal-title":"Retina"},{"key":"R12-20250331","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1167\/tvst.12.4.21","article-title":"Silicone oil tamponade removal: which technique is more effective? An x-ray photoemission spectroscopy study","volume":"12","author":"Rossi","year":"2023","journal-title":"Transl Vis Sci Tech"},{"key":"R13-20250331","doi-asserted-by":"crossref","first-page":"1697","DOI":"10.1007\/s00417-017-3701-2","article-title":"Effect of fluid-air exchange on reducing residual silicone oil after silicone oil removal","volume":"255","author":"Shiihara","year":"2017","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"R14-20250331","first-page":"8184607","article-title":"Comparison of repeated fluid-air exchange and passive drainage for removing residual emulsified silicone oil droplets","volume":"2020","author":"Yu","year":"2020","journal-title":"J Ophthalmol"},{"key":"R15-20250331","doi-asserted-by":"crossref","first-page":"1014","DOI":"10.1167\/iovs.14-15061","article-title":"A low-molecular-weight oil cleaner for removal of leftover silicone oil intraocular tamponade","volume":"56","author":"Chan","year":"2015","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R16-20250331","doi-asserted-by":"crossref","first-page":"1193","DOI":"10.1097\/IAE.0b013e31817c5a28","article-title":"23-gauge vitrectomy in 100 eyes: short-term visual outcomes and complications","volume":"28","author":"Lott","year":"2008","journal-title":"Retina"},{"key":"R17-20250331","first-page":"8","article-title":"Intraocular gas in vitreoretinal surgery","volume":"14","author":"Mohamed","year":"2010","journal-title":"Hong Kong J Ophthalmol"},{"key":"R18-20250331","doi-asserted-by":"crossref","first-page":"96","DOI":"10.1016\/j.saa.2016.05.036","article-title":"An investigation of the effect of silicone oil on polymer intraocular lenses by means of PALS, FT-IR and Raman spectroscopies","volume":"167","author":"Chamerski","year":"2016","journal-title":"Spectrochimica Acta Part A: Mol Biomol Spectrosc"},{"key":"R19-20250331","doi-asserted-by":"crossref","first-page":"291","DOI":"10.1136\/bjophthalmol-2019-313823","article-title":"Release of silicone oil and the off-label use of syringes in ophthalmology","volume":"104","author":"Melo","year":"2020","journal-title":"Br J Ophthalmol"},{"key":"R20-20250331","doi-asserted-by":"crossref","first-page":"111265","DOI":"10.1016\/j.colsurfb.2020.111265","article-title":"Study of wetting of the animal retinas by Water and organic liquids and its Implications for ophthalmology","volume":"195","author":"Rubowitz","year":"2020","journal-title":"Colloids Surf B Biointerfaces"},{"key":"R21-20250331","doi-asserted-by":"crossref","first-page":"1810","DOI":"10.1038\/s41433-024-03027-y","article-title":"Refinements in the use of silicone oil as an intraocular tamponade","volume":"38","author":"Wilson","year":"2024","journal-title":"Eye (Lond)"},{"key":"R22-20250331","doi-asserted-by":"crossref","first-page":"102541","DOI":"10.1016\/j.cis.2021.102541","article-title":"Emulsion characterization via microfluidic devices: a review on interfacial tension and stability to coalescence","volume":"299","author":"Ho","year":"2022","journal-title":"Adv Colloid Interf Sci"},{"key":"R23-20250331","first-page":"73","article-title":"Understanding the latest vitrectomy machines","volume":"10","author":"Chinskey","year":"2015","journal-title":"Retina Today"},{"key":"R24-20250331","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1097\/IAE.0000000000002837","article-title":"Anatomical and visual outcomes in stage 5 retinopathy of prematurity with microincision vitrectomy surgery","volume":"41","author":"Sen","year":"2021","journal-title":"Retina"},{"key":"R25-20250331","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1111\/j.1600-0420.2007.00988.x","article-title":"Fluid dynamics in three 25-gauge vitrectomy systems: principles for use in vitreoretinal surgery","volume":"86","author":"Magalhaes","year":"2008","journal-title":"Acta Ophthalmol"},{"key":"R26-20250331","doi-asserted-by":"crossref","first-page":"e232","DOI":"10.1111\/aos.14212","article-title":"Amphiphilic additives in silicone oil tamponade and emulsification: an eye on a chip study","volume":"98","author":"Lu","year":"2020","journal-title":"Acta Ophthalmol"},{"key":"R27-20250331","doi-asserted-by":"crossref","first-page":"e209","DOI":"10.1111\/aos.14539","article-title":"Assessing bulk emulsification at the silicone oil - saline solution interface in a 3D model of the eye","volume":"99","author":"Wang","year":"2021","journal-title":"Acta Ophthalmol"},{"key":"R28-20250331","doi-asserted-by":"crossref","first-page":"313","DOI":"10.1111\/aos.13982","article-title":"Adhesion of silicone oil and emulsification: an in vitro assessment using a microfluidic device and 'Eye-on-a-Chip","volume":"97","author":"Lu","year":"2019","journal-title":"Acta Ophthalmol"}],"container-title":["Retina"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/IAE.0000000000004353","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,3,31]],"date-time":"2025-03-31T19:13:32Z","timestamp":1743448412000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/IAE.0000000000004353"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4]]},"references-count":28,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/iae.0000000000004353","relation":{},"ISSN":["0275-004X","1539-2864"],"issn-type":[{"value":"0275-004X","type":"print"},{"value":"1539-2864","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,4]]}}}