{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,19]],"date-time":"2026-06-19T10:26:45Z","timestamp":1781864805469,"version":"3.54.5"},"reference-count":33,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","license":[{"start":{"date-parts":[[2025,5,1]],"date-time":"2025-05-01T00:00:00Z","timestamp":1746057600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,5]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>Anterior chamber air injection (ACAI) is a surgical technique used to decrease the occurrence of postoperative intraocular lens (IOL) haptic dislocation after phacovitrectomy with gas\/air tamponade. The impact of this technique on IOL stability remains uncertain, prompting the design of this study to investigate further.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>This study included 51 eyes of 51 patients who underwent phacovitrectomy with gas\/air tamponade. The patients were divided into two groups: Group 1 (ACAI group, 26 eyes) and Group 2 (non-ACAI group, 25 eyes). Intraocular lens position is used to determine the IOL axial movement. The study analyzed changes in lens\/IOL decentration, tilt, and aqueous depth using repeated measures analysis of variance. The linear regression model was used to investigate the factors influencing the IOL stability.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>There was no significant difference in IOL decentration, tilt, mean prediction error, and mean absolute error between the two groups. Anterior chamber air injection not only caused the IOL position to move axially forward but also the aqueous depth to take longer to stabilize. Preoperative lens tilt is a significant factor influencing postoperative IOL tilt. In addition, sex, ACAI, and aqueous width are identified as factors that affect IOL position.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion:<\/jats:title>\n            <jats:p>ACAI is a factor that can affect IOL instability, and the surgeon needs to consider the necessity of ACAI when performing phacovitrectomy with gas\/air tamponade.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/iae.0000000000004382","type":"journal-article","created":{"date-parts":[[2025,1,6]],"date-time":"2025-01-06T23:00:21Z","timestamp":1736204421000},"page":"854-862","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":2,"title":["EFFECT OF ANTERIOR CHAMBER AIR INJECTION ON INTRAOCULAR LENS STABILITY AFTER PHACOVITRECTOMY WITH GAS\/AIR TAMPONADE"],"prefix":"10.1097","volume":"45","author":[{"given":"Zigan","family":"Zhou","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bi","family":"Sun","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xingyi","family":"Wu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuhao","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Binghua","family":"Guo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chen","family":"Yang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhong","family":"Lin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3104-1553","authenticated-orcid":false,"given":"Ronghan","family":"Wu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20250422","doi-asserted-by":"crossref","first-page":"1415","DOI":"10.1097\/IAE.0000000000000072","article-title":"Accuracy of intraocular lens power estimation in eyes having phacovitrectomy for rhegmatogenous retinal detachment","volume":"34","author":"Rahman","year":"2014","journal-title":"Retina"},{"key":"R2-20250422","doi-asserted-by":"crossref","first-page":"700","DOI":"10.1016\/j.oret.2020.01.022","article-title":"Prospective comparison of intraocular lens dynamics and refractive error between phacovitrectomy and phacoemulsification alone","volume":"4","author":"Sato","year":"2020","journal-title":"Ophthalmol Retina"},{"key":"R3-20250422","doi-asserted-by":"crossref","first-page":"2026","DOI":"10.1097\/IAE.0b013e3182561fab","article-title":"Comparison of intraoperative complications of phacoemulsification between sequential and combined procedures of pars plana vitrectomy and cataract surgery","volume":"32","author":"Lee","year":"2012","journal-title":"Retina"},{"key":"R4-20250422","doi-asserted-by":"crossref","first-page":"1648","DOI":"10.1016\/S0161-6420(97)30071-2","article-title":"Long-term visual outcomes in patients with successful macular hole surgery","volume":"104","author":"Leonard","year":"1997","journal-title":"Ophthalmology"},{"key":"R5-20250422","doi-asserted-by":"crossref","first-page":"291","DOI":"10.1016\/S0002-9394(02)01972-4","article-title":"Combined phacoemulsification, intraocular lens implantation, and vitrectomy for eyes with coexisting cataract and vitreoretinal pathology","volume":"135","author":"Demetriades","year":"2003","journal-title":"Am J Ophthalmol"},{"key":"R6-20250422","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1016\/j.ophtha.2009.06.043","article-title":"A 27-gauge instrument system for transconjunctival sutureless microincision vitrectomy surgery","volume":"117","author":"Oshima","year":"2010","journal-title":"Ophthalmology"},{"key":"R7-20250422","doi-asserted-by":"crossref","first-page":"1807","DOI":"10.1016\/S0161-6420(02)01179-X","article-title":"A new 25-gauge instrument system for transconjunctival sutureless vitrectomy surgery","volume":"109","author":"Fujii","year":"2002","journal-title":"Ophthalmology"},{"key":"R8-20250422","doi-asserted-by":"crossref","first-page":"1925","DOI":"10.2147\/OPTH.S37864","article-title":"Faster recovery after 25-gauge microincision vitrectomy surgery than after 20-gauge vitrectomy in patients with proliferative diabetic retinopathy","volume":"6","author":"Sato","year":"2012","journal-title":"Clin Ophthalmol"},{"key":"R9-20250422","doi-asserted-by":"crossref","first-page":"1126","DOI":"10.1097\/j.jcrs.0000000000000219","article-title":"Characteristics and factors associated with intraocular lens tilt and decentration after cataract surgery","volume":"46","author":"Chen","year":"2020","journal-title":"J Cataract Refract Surg"},{"key":"R10-20250422","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1167\/tvst.10.3.26","article-title":"Characteristics and risk factors of intraocular lens tilt and decentration of phacoemulsification after pars plana vitrectomy","volume":"10","author":"Tan","year":"2021","journal-title":"Transl Vis Sci Technol"},{"key":"R11-20250422","doi-asserted-by":"crossref","first-page":"3438","DOI":"10.3390\/jcm11123438","article-title":"Comparison of postoperative stability of intraocular lenses after phacovitrectomy for rhegmatogenous retinal detachment","volume":"11","author":"Akiyama","year":"2022","journal-title":"J Clin Med"},{"key":"R12-20250422","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1007\/s10384-020-00737-0","article-title":"Impact of vitrectomy and air tamponade on aspheric intraocular lens tilt and decentration and ocular higher-order aberrations: phacovitrectomy versus cataract surgery","volume":"64","author":"Iwama","year":"2020","journal-title":"Jpn J Ophthalmol"},{"key":"R13-20250422","doi-asserted-by":"crossref","first-page":"511","DOI":"10.1016\/j.ophtha.2019.10.021","article-title":"Effect of gas tamponade on the intraocular lens position and refractive error after phacovitrectomy: a swept-source anterior segment OCT analysis","volume":"127","author":"Shiraki","year":"2020","journal-title":"Ophthalmology"},{"key":"R14-20250422","doi-asserted-by":"crossref","first-page":"1318","DOI":"10.1097\/j.jcrs.0000000000000997","article-title":"Predicting the risk of clinically significant intraocular lens tilt and decentration in vitrectomized eyes","volume":"48","author":"Zhang","year":"2022","journal-title":"J Cataract Refract Surg"},{"key":"R15-20250422","doi-asserted-by":"crossref","first-page":"705","DOI":"10.1016\/S0161-6420(95)30965-7","article-title":"Endophthalmitis after pars plana vitrectomy. The postvitrectomy endophthalmitis study group","volume":"102","author":"Cohen","year":"1995","journal-title":"Ophthalmology"},{"key":"R16-20250422","doi-asserted-by":"crossref","first-page":"1207","DOI":"10.1097\/IAE.0000000000001401","article-title":"Intracameral air in phacovitrectomy for maintaining intraocular lens position","volume":"37","author":"Tye","year":"2017","journal-title":"Retina"},{"key":"R17-20250422","doi-asserted-by":"crossref","first-page":"10230","DOI":"10.1038\/s41598-018-28609-1","article-title":"Short-term dynamics after single- and three-piece acrylic intraocular lens implantation: a swept-source anterior segment optical coherence tomography study","volume":"8","author":"Sato","year":"2018","journal-title":"Sci Rep"},{"key":"R18-20250422","doi-asserted-by":"crossref","first-page":"e0184066","DOI":"10.1371\/journal.pone.0184066","article-title":"Assessment of tilt and decentration of crystalline lens and intraocular lens relative to the corneal topographic axis using anterior segment optical coherence tomography","volume":"12","author":"Kimura","year":"2017","journal-title":"PLoS One"},{"key":"R19-20250422","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1167\/iovs.61.5.40","article-title":"Morphologic features of crystalline lens in patients with primary angle closure disease observed by CASIA 2 optical coherence tomography","volume":"61","author":"Wang","year":"2020","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R20-20250422","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1016\/j.ophtha.2017.08.027","article-title":"Accuracy of intraocular lens calculation formulas","volume":"125","author":"Melles","year":"2018","journal-title":"Ophthalmology"},{"key":"R21-20250422","doi-asserted-by":"crossref","first-page":"548","DOI":"10.1016\/j.jcrs.2014.06.033","article-title":"Intraocular lens power calculation for eyes with an axial length greater than 26.0 mm: comparison of formulas and methods","volume":"41","author":"Abulafia","year":"2015","journal-title":"J Cataract Refract Surg"},{"key":"R22-20250422","doi-asserted-by":"crossref","first-page":"2193","DOI":"10.1016\/j.ophtha.2015.07.003","article-title":"The first 100 eyes of standardized descemet stripping automated endothelial keratoplasty versus standardized descemet membrane endothelial keratoplasty","volume":"122","author":"Hamzaoglu","year":"2015","journal-title":"Ophthalmology"},{"key":"R23-20250422","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1111\/j.1442-9071.2010.02461.x","article-title":"Descemet-stripping automated endothelial keratoplasty: a successful alternative to repeat penetrating keratoplasty","volume":"39","author":"Lee","year":"2011","journal-title":"Clin Exp Ophthalmol"},{"key":"R24-20250422","doi-asserted-by":"crossref","first-page":"1116","DOI":"10.1016\/j.jcrs.2014.04.023","article-title":"Air reinjection and endothelial cell density in Descemet membrane endothelial keratoplasty: five-year follow-up","volume":"40","author":"Feng","year":"2014","journal-title":"J Cataract Refract Surg"},{"key":"R25-20250422","doi-asserted-by":"crossref","first-page":"2279","DOI":"10.1167\/iovs.10-6187","article-title":"Corneal endothelial toxicity of air and SF6","volume":"52","author":"Landry","year":"2011","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R26-20250422","doi-asserted-by":"crossref","first-page":"1757","DOI":"10.1016\/j.ophtha.2015.05.013","article-title":"Comparison of sulfur hexafluoride 20% versus air tamponade in descemet membrane endothelial keratoplasty","volume":"122","author":"G\u00fcell","year":"2015","journal-title":"Ophthalmology"},{"key":"R27-20250422","doi-asserted-by":"crossref","first-page":"118","DOI":"10.1159\/000499116","article-title":"Effect of air tamponade on tilt of the intraocular lens after phacovitrectomy","volume":"242","author":"Leisser","year":"2019","journal-title":"Ophthalmologica"},{"key":"R28-20250422","doi-asserted-by":"crossref","first-page":"388","DOI":"10.1111\/j.1600-0420.2006.00647.x","article-title":"Tilt and decentration of the intraocular lens following combined vitrectomy and pars plana lensectomy","volume":"84","author":"Ohara","year":"2006","journal-title":"Acta Ophthalmol Scand"},{"key":"R29-20250422","doi-asserted-by":"crossref","first-page":"403","DOI":"10.1016\/j.ajo.2015.05.029","article-title":"Protocols for studies of intraocular lens formula accuracy","volume":"160","author":"Hoffer","year":"2015","journal-title":"Am J Ophthalmol"},{"key":"R30-20250422","doi-asserted-by":"crossref","first-page":"2207","DOI":"10.1097\/IAE.0000000000001840","article-title":"Intraocular lens position in combined phacoemulsification and vitreoretinal surgery","volume":"38","author":"Ozates","year":"2018","journal-title":"Retina"},{"key":"R31-20250422","doi-asserted-by":"crossref","first-page":"e793","DOI":"10.1097\/SCS.0000000000003133","article-title":"Evaluation of eyeball and orbit in relation to gender and age","volume":"27","author":"\u00d6zer","year":"2016","journal-title":"J Craniofac Surg"},{"key":"R32-20250422","doi-asserted-by":"crossref","first-page":"2130","DOI":"10.1038\/s41433-021-01815-4","article-title":"Three-dimensional assessment of posterior capsule-intraocular lens interaction with and without primary posterior capsulorrhexis: an intraindividual randomized trial","volume":"36","author":"Yu","year":"2022","journal-title":"Eye"},{"key":"R33-20250422","doi-asserted-by":"crossref","first-page":"2278","DOI":"10.1016\/j.ophtha.2010.03.053","article-title":"Intraocular lens stability and refractive outcomes after cataract surgery using primary posterior continuous curvilinear capsulorrhexis","volume":"117","author":"Kim","year":"2010","journal-title":"Ophthalmology"}],"container-title":["Retina"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/IAE.0000000000004382","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,4,22]],"date-time":"2025-04-22T20:00:57Z","timestamp":1745352057000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/IAE.0000000000004382"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5]]},"references-count":33,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/iae.0000000000004382","relation":{},"ISSN":["0275-004X","1539-2864"],"issn-type":[{"value":"0275-004X","type":"print"},{"value":"1539-2864","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,5]]}}}