{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,30]],"date-time":"2025-12-30T20:08:34Z","timestamp":1767125314328,"version":"3.44.0"},"reference-count":27,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"9","funder":[{"name":"Key Technologies Research and Development Program of Anhui Province","award":["2022YFC2404203"],"award-info":[{"award-number":["2022YFC2404203"]}]},{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"crossref","award":["82070980"],"award-info":[{"award-number":["82070980"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,9]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>To describe a simplified technique for correcting intraocular lens (IOL) decentration during scleral-sutured IOL fixation surgery.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>During surgery, Purkinje images were used to assess IOL positioning. A straightforward IOL decentration adjustment technique was used when necessary. Patients in whom IOL position were corrected and who were followed up for at least 3 months after surgery were included in the study.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>From June 2023 to February 2024, six patients with noticeable IOL decentration were successfully treated using this technique. After a mean follow-up of 3.17 \u00b1 0.37 months, there was a significant change in spherical equivalent (preoperative +10.55 \u00b1 2.48 diopter [D], postoperative \u22121.58 \u00b1 2.19 D). While the best-corrected visual acuity, refractive cylinder, intraocular pressure, and corneal endothelium density remained unchanged. Importantly, the IOL was well-centered in all six patients, with average horizontal and vertical IOL decentration of 0.21 \u00b1 0.16 mm and 0.20 \u00b1 0.15 mm, respectively.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion:<\/jats:title>\n            <jats:p>This simple IOL decentration correction technique demonstrated favorable results and may enhance IOL positioning in scleral fixation procedures.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/iae.0000000000004401","type":"journal-article","created":{"date-parts":[[2025,1,22]],"date-time":"2025-01-22T16:01:01Z","timestamp":1737561661000},"page":"1799-1803","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["Simplified Technique for Correcting Intraocular Lens Decentration in Scleral-Sutured Fixation Surgery"],"prefix":"10.1097","volume":"45","author":[{"given":"Jiemei","family":"Shi","sequence":"first","affiliation":[{"name":"Department of Ophthalmology and Vision Science, Eye and ENT Hospital, Fudan University, Shanghai, People's Republic of China; and"},{"name":"Key Laboratory of Myopia and Related Eye Diseases, NHC, Shanghai, People's Republic of China."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yuan","family":"Zong","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology and Vision Science, Eye and ENT Hospital, Fudan University, Shanghai, People's Republic of China; and"},{"name":"Key Laboratory of Myopia and Related Eye Diseases, NHC, Shanghai, People's Republic of China."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kaicheng","family":"Wu","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology and Vision Science, Eye and ENT Hospital, Fudan University, Shanghai, People's Republic of China; and"},{"name":"Key Laboratory of Myopia and Related Eye Diseases, NHC, Shanghai, People's Republic of China."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chunhui","family":"Jiang","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology and Vision Science, Eye and ENT Hospital, Fudan University, Shanghai, People's Republic of China; and"},{"name":"Key Laboratory of Myopia and Related Eye Diseases, NHC, Shanghai, People's Republic of China."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20250819","doi-asserted-by":"crossref","first-page":"50","DOI":"10.1097\/ICU.0000000000000632","article-title":"Scleral fixation of intraocular lenses","volume":"31","author":"Jacob","year":"2020","journal-title":"Curr Opin Ophthalmol"},{"key":"R2-20250819","doi-asserted-by":"crossref","first-page":"662","DOI":"10.1016\/j.jcrs.2018.10.049","article-title":"Effects of decentration and tilt on the optical performance of 6 aspheric intraocular lens designs in a model eye","volume":"45","author":"Lawu","year":"2019","journal-title":"J Cataract Refract Surg"},{"key":"R3-20250819","doi-asserted-by":"crossref","first-page":"878","DOI":"10.1016\/S0161-6420(99)00504-7","article-title":"Intraocular lens tilt and decentration, anterior chamber depth, and refractive error after trans-scleral suture fixation surgery","volume":"106","author":"Hayashi","year":"1999","journal-title":"Ophthalmology"},{"key":"R4-20250819","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1136\/bjo.2006.099945","article-title":"Influence of tilt and decentration of scleral-sutured intraocular lens on ocular higher-order wavefront aberration","volume":"91","author":"Oshika","year":"2007","journal-title":"Br J Ophthalmol"},{"key":"R5-20250819","doi-asserted-by":"crossref","first-page":"1602","DOI":"10.1097\/IAE.0000000000001147","article-title":"Combined 27-gauge pars plana vitrectomy and scleral fixation of an Akreos AO60 intraocular lens using Gore-Tex suture","volume":"36","author":"Khan","year":"2016","journal-title":"Retina"},{"key":"R6-20250819","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1016\/j.ophtha.2013.08.043","article-title":"Sutureless 27-gauge needle-guided intrascleral intraocular lens implantation with lamellar scleral dissection","volume":"121","author":"Yamane","year":"2014","journal-title":"Ophthalmology"},{"key":"R7-20250819","doi-asserted-by":"crossref","first-page":"1308","DOI":"10.1097\/j.jcrs.0000000000000615","article-title":"Adjustment of intraocular lens tilt during intrascleral fixation assisted by intraoperative OCT","volume":"47","author":"Fukumoto","year":"2021","journal-title":"J Cataract Refract Surg"},{"key":"R8-20250819","doi-asserted-by":"crossref","first-page":"2089","DOI":"10.1097\/IAE.0000000000003799","article-title":"Scleral suture intraocular lens fixation under microscope-intraoperative optical coherence tomography","volume":"43","author":"Shi","year":"2023","journal-title":"Retina"},{"key":"R9-20250819","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1016\/S0886-3350(88)80086-5","article-title":"Measurement of intraocular lens decentration and tilt in vivo","volume":"14","author":"Phillips","year":"1988","journal-title":"J Cataract Refract Surg"},{"key":"R10-20250819","doi-asserted-by":"crossref","first-page":"3517461","DOI":"10.1155\/2017\/3517461","article-title":"Tilt, decentration, and internal higher-order aberrations of sutured posterior-chamber intraocular lenses in patients with open globe injuries","volume":"2017","author":"Zhu","year":"2017","journal-title":"J Ophthalmol"},{"key":"R11-20250819","doi-asserted-by":"crossref","first-page":"839","DOI":"10.1007\/s10792-018-0883-5","article-title":"A comparative study of transscleral suture-fixated and scleral-fixated intraocular lens implantation","volume":"39","author":"Mizuno","year":"2019","journal-title":"Int Ophthalmol"},{"key":"R12-20250819","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1016\/j.jcrs.2005.06.050","article-title":"Ab externo scleral suture loop fixation for posterior chamber intraocular lens decentration: clinical results","volume":"32","author":"Chan","year":"2006","journal-title":"J Cataract Refract Surg"},{"key":"R13-20250819","doi-asserted-by":"crossref","first-page":"1259","DOI":"10.1016\/S0161-6420(90)32422-3","article-title":"Rapid determination of intraocular lens tilt and decentration through the undilated pupil","volume":"97","author":"Guyton","year":"1990","journal-title":"Ophthalmology"},{"key":"R14-20250819","doi-asserted-by":"crossref","first-page":"167","DOI":"10.1136\/bjo.2009.162180","article-title":"Z-suture: a new knotless technique for transscleral suture fixation of intraocular implants","volume":"94","author":"Szurman","year":"2010","journal-title":"Br J Ophthalmol"},{"key":"R15-20250819","doi-asserted-by":"crossref","first-page":"712","DOI":"10.1136\/bjophthalmol-2019-314054","article-title":"Long-term outcome of scleral-sutured posterior chamber intraocular lens: a case series","volume":"104","author":"Bausili Portabella","year":"2020","journal-title":"Br J Ophthalmol"},{"key":"R16-20250819","doi-asserted-by":"crossref","first-page":"693","DOI":"10.1136\/bjo.2009.161349","article-title":"Four-point scleral fixation of posterior chamber intraocular lenses without scleral flaps","volume":"94","author":"Almashad","year":"2010","journal-title":"Br J Ophthalmol"},{"key":"R17-20250819","doi-asserted-by":"crossref","first-page":"2059","DOI":"10.1097\/IAE.0000000000003601","article-title":"Four-point scleral fixation of an Akreos adapt AO intraocular lens using double-strand 9-0 polypropylene suture","volume":"43","author":"Chen","year":"2023","journal-title":"Retina"},{"key":"R18-20250819","doi-asserted-by":"crossref","first-page":"805706","DOI":"10.1155\/2015\/805706","article-title":"Epidemiology, etiology, and prevention of late IOL-capsular bag complex dislocation: review of the literature","volume":"2015","author":"Ascaso","year":"2015","journal-title":"J Ophthalmol"},{"key":"R19-20250819","doi-asserted-by":"crossref","first-page":"1136","DOI":"10.1016\/j.ophtha.2017.03.036","article-title":"Flanged intrascleral intraocular lens fixation with double-needle technique","volume":"124","author":"Yamane","year":"2017","journal-title":"Ophthalmology"},{"key":"R20-20250819","doi-asserted-by":"crossref","first-page":"771","DOI":"10.1111\/aos.14108","article-title":"Cost-effectiveness analysis in a randomized trial of late in-the-bag intraocular lens dislocation surgery: repositioning versus exchange","volume":"97","author":"Kristianslund","year":"2019","journal-title":"Acta Ophthalmol"},{"key":"R21-20250819","doi-asserted-by":"crossref","first-page":"6181","DOI":"10.1038\/s41598-024-54694-6","article-title":"Repositioned versus exchanged flanged intraocular lens fixation for intraocular lens dislocation","volume":"14","author":"Kang","year":"2024","journal-title":"Sci Rep"},{"key":"R22-20250819","doi-asserted-by":"crossref","first-page":"417","DOI":"10.1016\/S0039-6257(97)00140-9","article-title":"Intraocular lens complications requiring removal or exchange","volume":"42","author":"Carlson","year":"1998","journal-title":"Surv Ophthalmol"},{"key":"R23-20250819","first-page":"35","article-title":"Centering IOLs using Purkinje images","volume":"35","author":"Chang","year":"2011","journal-title":"Cataract Refract Surg Today"},{"key":"R24-20250819","doi-asserted-by":"crossref","first-page":"863","DOI":"10.1016\/j.ajo.2014.06.028","article-title":"The subject-fixated coaxially sighted corneal light reflex: a clinical marker for centration of refractive treatments and devices","volume":"158","author":"Chang","year":"2014","journal-title":"Am J Ophthalmol"},{"key":"R25-20250819","doi-asserted-by":"crossref","first-page":"400","DOI":"10.1111\/j.1444-0938.2010.00514.x","article-title":"Intraocular lens alignment from Purkinje and Scheimpflug imaging","volume":"93","author":"Rosales","year":"2010","journal-title":"Clin Exp Optom"},{"key":"R26-20250819","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1016\/S0886-3350(00)00638-6","article-title":"Tilt and decentration after primary and secondary transsclerally sutured posterior chamber intraocular lens implantation","volume":"27","author":"Durak","year":"2001","journal-title":"J Cataract Refract Surg"},{"key":"R27-20250819","doi-asserted-by":"crossref","first-page":"100","DOI":"10.1186\/s12886-016-0283-4","article-title":"Comparisons of the in-the-bag stabilities of single-piece and three-piece intraocular lenses for age-related cataract patients: a randomized controlled trial","volume":"16","author":"Zhong","year":"2016","journal-title":"BMC Ophthalmol"}],"container-title":["Retina"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/IAE.0000000000004401","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,19]],"date-time":"2025-08-19T15:00:37Z","timestamp":1755615637000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/IAE.0000000000004401"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,9]]},"references-count":27,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/iae.0000000000004401","relation":{},"ISSN":["0275-004X","1539-2864"],"issn-type":[{"type":"print","value":"0275-004X"},{"type":"electronic","value":"1539-2864"}],"subject":[],"published":{"date-parts":[[2025,9]]}}}