{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,5,28]],"date-time":"2025-05-28T04:15:25Z","timestamp":1748405725787,"version":"3.41.0"},"reference-count":27,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"6","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,6]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>To report the characteristics and the surgical outcomes of full-thickness macular holes (MHs) accidently caused by laser devices and analyze the visual predictors.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>Thirty-three eyes that underwent vitrectomy for laser-induced MHs were included. Full ophthalmic examinations and optical coherence tomography were used for assessment at baseline and at follow-ups. Preoperative and 6 months postoperative features were analyzed, respectively, as potential predictors of final visual acuity (VA).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>Eleven eyes were injured by a neodymium-doped yttrium aluminum garnet laser and 22 by a handheld laser. Five of 33 eyes had a focal subfoveal choroidal depression preoperatively. Macular hole closure was achieved in 87.9% eyes. In total, 79.3% eyes had VA improvement of two or more lines. Compromised VA improvement was associated with preoperative choroidal depression (<jats:italic toggle=\"yes\">P<\/jats:italic> = 0.026, odds ratio = 0.068, 95% confidence interval [CI]: 0.006\u20130.729). Worse final best-corrected visual acuity was associated with worse preoperative best-corrected visual acuity (<jats:italic toggle=\"yes\">P<\/jats:italic> = 0.001, regression coefficient [B] = 0.497, 95% CI: 0.221\u20130.774), preoperative choroidal depression (<jats:italic toggle=\"yes\">P<\/jats:italic> = 0.014, B = 0.353, 95% CI: 0.078\u20130.628), neodymium-doped yttrium aluminum garnet laser injury (<jats:italic toggle=\"yes\">P<\/jats:italic> = 0.030, B=\u22120.244, 95% CI: \u22120.461 to \u22120.026), larger MH diameter (<jats:italic toggle=\"yes\">P<\/jats:italic> = 0.023, B = 0.031, 95% CI: 0.005\u20130.058), failed MH closure (<jats:italic toggle=\"yes\">P<\/jats:italic> = 0.003, B=\u22120.472, 95% CI: \u22120.775 to \u22120.169), larger ellipsoid zone defect at 6 months (<jats:italic toggle=\"yes\">P<\/jats:italic> = 0.002, B = 0.053, 95% CI: 0.024\u20130.082), and thinner foveal neuroretina thickness at 6 months (<jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.001, B=\u22120.365, 95% CI: \u22120.520 to \u22120.211).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion:<\/jats:title>\n            <jats:p>Vitrectomy is effective in closing laser-induced MHs and improving VA. Preoperative factors including worse preoperative best-corrected visual acuity, choroidal depression, neodymium-doped yttrium aluminum garnet laser injury, and larger MH diameter and postoperative factors including failed MH closure, larger ellipsoid zone defect, and thinner foveal neuroretina at 6 months are predictive factors for worse final VA.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/iae.0000000000004415","type":"journal-article","created":{"date-parts":[[2025,1,27]],"date-time":"2025-01-27T23:01:43Z","timestamp":1738018903000},"page":"1097-1107","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["CHARACTERISTICS AND SURGICAL OUTCOMES OF LASER-INDUCED FULL-THICKNESS MACULAR HOLES"],"prefix":"10.1097","volume":"45","author":[{"given":"Ying","family":"Cui","sequence":"first","affiliation":[{"name":"Department of Ophthalmology, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing, China; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wu","family":"Liu","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing, China; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yaxing","family":"Wang","sequence":"additional","affiliation":[{"name":"Beijing Institute of Ophthalmology, Beijing Tongren Hospital, Capital Medical University, Beijing, China."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiangyu","family":"Shi","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing, China; and"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20250527","doi-asserted-by":"crossref","first-page":"803","DOI":"10.1136\/bjo.81.9.802b","article-title":"Vitrectomy and autologous thrombocyte adhesion of an accidental macular hole caused by Nd:YAG laser","volume":"81","author":"Potth\u00f6fer","year":"1997","journal-title":"Br J Ophthalmol"},{"key":"R2-20250527","doi-asserted-by":"crossref","first-page":"355","DOI":"10.1016\/S0002-9394(00)00547-X","article-title":"Amsler grid examination and optical coherence tomography of a macular hole caused by accidental Nd:YAG laser injury","volume":"130","author":"Sakaguchi","year":"2000","journal-title":"Am J Ophthalmol"},{"key":"R3-20250527","doi-asserted-by":"crossref","first-page":"714","DOI":"10.1097\/00006982-200310000-00020","article-title":"Vitrectomy with indocyanine green-guided inner limiting membrane peeling for a Q-switched Nd:YAG laser-induced macular hole","volume":"23","author":"Ben-Simon","year":"2003","journal-title":"Retina"},{"key":"R4-20250527","doi-asserted-by":"crossref","first-page":"537","DOI":"10.1016\/S0002-9394(02)02075-5","article-title":"Optical coherence tomographic evaluation of a surgically treated traumatic macular hole secondary to Nd:YAG laser injury","volume":"135","author":"Sou","year":"2003","journal-title":"Am J Ophthalmol"},{"key":"R5-20250527","doi-asserted-by":"crossref","first-page":"571","DOI":"10.1038\/sj.eye.6702660","article-title":"Traumatic macular hole secondary to Nd:YAG laser","volume":"21","author":"Gao","year":"2007","journal-title":"Eye (Lond)"},{"key":"R6-20250527","doi-asserted-by":"crossref","first-page":"80","DOI":"10.1159\/000321631","article-title":"Vitrectomy and microperimetry of an accidental macular hole caused by Nd:YAG laser","volume":"1","author":"Chen","year":"2010","journal-title":"Case Rep Ophthalmol"},{"key":"R7-20250527","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1016\/j.tjo.2016.05.005","article-title":"Vitrectomy for macular hole following Nd:YAG laser injury","volume":"6","author":"Stein","year":"2016","journal-title":"Taiwan J Ophthalmol"},{"key":"R8-20250527","doi-asserted-by":"crossref","first-page":"345","DOI":"10.1016\/j.pdpdt.2017.07.001","article-title":"Focal choroidal excavation and a traumatic macular hole secondary to accidental Q-switched Nd:YAG laser","volume":"19","author":"Shuai","year":"2017","journal-title":"Photodiagnosis Photodyn Ther"},{"key":"R9-20250527","doi-asserted-by":"crossref","first-page":"e18185","DOI":"10.1097\/MD.0000000000018185","article-title":"Inverted internal limiting membrane flap technique and an autologous platelet concentrate to treat an Nd: YAG laser-induced macular hole: a case report","volume":"98","author":"Yang","year":"2019","journal-title":"Medicine (Baltimore)"},{"key":"R10-20250527","doi-asserted-by":"crossref","first-page":"101391","DOI":"10.1016\/j.ajoc.2022.101391","article-title":"A case of Nd:YAG laser-induced traumatic macular hole with good visual prognosis after vitrectomy with inverted internal limiting membrane technique","volume":"25","author":"Kuwayama","year":"2022","journal-title":"Am J Ophthalmol Case Rep"},{"key":"R11-20250527","doi-asserted-by":"crossref","first-page":"566","DOI":"10.1016\/j.ophtha.2013.09.006","article-title":"High-power handheld blue laser-induced maculopathy: the results of the King Khaled Eye Specialist Hospital Collaborative Retina Study Group","volume":"121","author":"Alsulaiman","year":"2014","journal-title":"Ophthalmology"},{"key":"R12-20250527","doi-asserted-by":"crossref","first-page":"668.e1","DOI":"10.1016\/j.jpeds.2013.11.019","article-title":"High-powered laser pointer injury resulting in macular hole formation","volume":"164","author":"Dhoot","year":"2014","journal-title":"J Pediatr"},{"key":"R13-20250527","doi-asserted-by":"crossref","first-page":"1780","DOI":"10.1016\/S0140-6736(14)60757-1","article-title":"Bilateral macular hole from a handheld laser pointer","volume":"383","author":"Petrou","year":"2014","journal-title":"Lancet"},{"key":"R14-20250527","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1016\/j.ajo.2015.04.014","article-title":"Full-thickness macular hole secondary to high-power handheld blue laser: natural history and management outcomes","volume":"160","author":"Alsulaiman","year":"2015","journal-title":"Am J Ophthalmol"},{"key":"R15-20250527","doi-asserted-by":"crossref","first-page":"1078","DOI":"10.1038\/eye.2017.41","article-title":"Surgical treatment and optical coherence tomographic evaluation for accidental laser-induced full-thickness macular holes","volume":"31","author":"Qi","year":"2017","journal-title":"Eye (Lond)"},{"key":"R16-20250527","doi-asserted-by":"crossref","first-page":"2420","DOI":"10.1056\/NEJMicm1714488","article-title":"Macular hole from a laser pointer","volume":"378","author":"Androudi","year":"2018","journal-title":"N Engl J Med"},{"key":"R17-20250527","doi-asserted-by":"crossref","first-page":"749","DOI":"10.1111\/aos.13856","article-title":"Laser pointer maculopathy\u2014on the rise?","volume":"96","author":"Torp-Pedersen","year":"2018","journal-title":"Acta Ophthalmol"},{"key":"R18-20250527","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1186\/s12886-021-01893-8","article-title":"Vitrectomy for laser-induced full-thickness macular hole","volume":"21","author":"Wang","year":"2021","journal-title":"Bmc Ophthalmol"},{"key":"R19-20250527","doi-asserted-by":"crossref","first-page":"314","DOI":"10.1097\/ICB.0000000000000963","article-title":"High-powered blue-light laser-induced maculopathy in an adolescent: multi-modal imaging, evolution, and management","volume":"16","author":"Botsford","year":"2022","journal-title":"Retin Cases Brief Rep"},{"key":"R20-20250527","doi-asserted-by":"crossref","first-page":"P41","DOI":"10.1177\/1120672121990633","article-title":"Internal limiting membrane peeling without vitrectomy for laser-induced macular holes in two children","volume":"32","author":"Chen","year":"2022","journal-title":"Eur J Ophthalmol"},{"key":"R21-20250527","doi-asserted-by":"crossref","first-page":"177","DOI":"10.1097\/ICB.0000000000001374","article-title":"The evolution of full-thickness macular hole after short exposure to high-powered handheld laser pointer","volume":"18","author":"Keshet","year":"2024","journal-title":"Retin Cases Brief Rep"},{"key":"R22-20250527","doi-asserted-by":"crossref","first-page":"2611","DOI":"10.1016\/j.ophtha.2013.07.042","article-title":"The International Vitreomacular Traction Study Group classification of vitreomacular adhesion, traction, and macular hole","volume":"120","author":"Duker","year":"2013","journal-title":"Ophthalmology"},{"key":"R23-20250527","doi-asserted-by":"crossref","first-page":"339","DOI":"10.1159\/000510149","article-title":"Surgical treatment for traumatic macular holes: reconstructive changes in foveal microstructures and visual predictors analysis","volume":"244","author":"Wang","year":"2021","journal-title":"Ophthalmologica"},{"key":"R24-20250527","doi-asserted-by":"crossref","first-page":"605","DOI":"10.1097\/00004032-198905000-00001","article-title":"Laser output characteristics","volume":"56","author":"Birngruber","year":"1989","journal-title":"Health Phys"},{"key":"R25-20250527","doi-asserted-by":"crossref","first-page":"929","DOI":"10.1001\/archopht.1997.01100160099023","article-title":"Surgical treatment of a macular hole secondary to accidental laser burn","volume":"115","author":"Ciulla","year":"1997","journal-title":"Arch Ophthalmol"},{"key":"R26-20250527","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1159\/000355492","article-title":"Predicting visual outcome following surgery for idiopathic macular holes","volume":"231","author":"Kusuhara","year":"2014","journal-title":"Ophthalmologica"},{"key":"R27-20250527","doi-asserted-by":"crossref","first-page":"92","DOI":"10.1097\/00006982-200402000-00013","article-title":"Laser-induced macular holes demonstrate impaired choroidal perfusion","volume":"24","author":"Allen","year":"2004","journal-title":"Retina"}],"container-title":["Retina"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/IAE.0000000000004415","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,27]],"date-time":"2025-05-27T14:47:10Z","timestamp":1748357230000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/IAE.0000000000004415"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,6]]},"references-count":27,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/iae.0000000000004415","relation":{},"ISSN":["0275-004X","1539-2864"],"issn-type":[{"type":"print","value":"0275-004X"},{"type":"electronic","value":"1539-2864"}],"subject":[],"published":{"date-parts":[[2025,6]]}}}