{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,4]],"date-time":"2026-08-04T16:20:57Z","timestamp":1785860457542,"version":"3.56.0"},"reference-count":23,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"7","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,7]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>To compare the anatomical and functional outcomes of the inverted internal limiting membrane (ILM) flap technique and ILM insertion technique for the treatment of large macular holes (MHs).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>\n                      Seventy-four consecutive eyes with large MHs (minimum diameter \u2265400\n                      <jats:italic toggle=\"yes\">\u00b5<\/jats:italic>\n                      m) were included. All patients underwent 25-gauge pars plana vitrectomy with inverted ILM flap technique (n = 40) or ILM insertion technique (n = 34). Swept source optical coherence tomography was performed before surgery and 12 months postoperatively. The rate of MH closure, postoperative best-corrected visual acuity, and swept source optical coherence tomography findings were evaluated at 12 months after surgery.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Macular hole closure was achieved in 34 eyes (85%) of the inverted ILM flap group and in 30 eyes (88.2%) of the ILM insertion group. There was no significant difference in the rate of MH closure (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.685). The mean best-corrected visual acuity improved from 1.30 \u00b1 0.81 logarithm of minimum angle of resolution (Snellen: 20\/400) at baseline to 0.64 \u00b1 0.67 logarithm of minimum angle of resolution (Snellen: 20\/87) at 12 months in the inverted ILM flap group, which was significantly better than that in the insertion ILM group (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.047). At 12 months, the mean external limiting membrane defect sizes were 106.68 \u00b1 196.25\n                      <jats:italic toggle=\"yes\">\u00b5<\/jats:italic>\n                      m in the inverted ILM flap group and 234.12 \u00b1 296.06\n                      <jats:italic toggle=\"yes\">\u00b5<\/jats:italic>\n                      m in the ILM insertion group, whereas the mean ellipsoid zone defect sizes were 167.08 \u00b1 223.08\n                      <jats:italic toggle=\"yes\">\u00b5<\/jats:italic>\n                      m and 261.58 \u00b1 290.92\n                      <jats:italic toggle=\"yes\">\u00b5<\/jats:italic>\n                      m, respectively. The mean external limiting membrane defect sizes were significantly smaller in the inverted ILM flap group than in the ILM insertion group (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.039). However, there was no significant difference in mean ellipsoid zone defect sizes between the two groups (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.160).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Both the inverted ILM flap and the insertion ILM techniques were associated with high rates of MH closure in large MHs. The inverted ILM flap technique seemed to be more effective surgery for large MHs compared with the ILM insertion technique in improving visual outcomes.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/iae.0000000000004443","type":"journal-article","created":{"date-parts":[[2025,3,3]],"date-time":"2025-03-03T17:00:22Z","timestamp":1741021222000},"page":"1353-1359","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":2,"title":["COMPARING THE INVERTED INTERNAL LIMITING MEMBRANE FLAP TECHNIQUE WITH THE INTERNAL LIMITING MEMBRANE INSERTION TECHNIQUE FOR TREATMENT OF LARGE MACULAR HOLES"],"prefix":"10.1097","volume":"45","author":[{"given":"Miao","family":"Zeng","sequence":"first","affiliation":[{"name":"Department of Ophthalmology, Central Theater Command General Hospital of PLA (Clinical Medicine Center of Eye Fundus Laser in Hubei Provience), Wuhan, Hubei, China; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chunyan","family":"Cai","sequence":"additional","affiliation":[{"name":"Aier Eye Hospital of Wuhan University, Wuhan, Hubei, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiao","family":"Chen","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Central Theater Command General Hospital of PLA (Clinical Medicine Center of Eye Fundus Laser in Hubei Provience), Wuhan, Hubei, China; and"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20250702","doi-asserted-by":"crossref","first-page":"1366","DOI":"10.1016\/j.ophtha.2009.01.052","article-title":"Population-based incidence of macular holes","volume":"116","author":"McCannel","year":"2009","journal-title":"Ophthalmology"},{"issue":"pt 2","key":"R2-20250702","doi-asserted-by":"crossref","first-page":"256","DOI":"10.1038\/eye.1998.60","article-title":"Systemic risk factors for idiopathic macular holes: a case-control study","volume":"12","author":"Evans","year":"1998","journal-title":"Eye (Lond)"},{"key":"R3-20250702","doi-asserted-by":"crossref","first-page":"1263","DOI":"10.1097\/IAE.0000000000002020","article-title":"The current surgical management of large, recurrent, or persistent macular holes","volume":"38","author":"Tam","year":"2018","journal-title":"Retina"},{"key":"R4-20250702","doi-asserted-by":"crossref","first-page":"2184","DOI":"10.1097\/IAE.0000000000001861","article-title":"Mechanism of \u201cflap closure\u201d after the inverted internal limiting membrane flap technique","volume":"38","author":"Boninska","year":"2018","journal-title":"Retina"},{"key":"R5-20250702","doi-asserted-by":"crossref","first-page":"654","DOI":"10.1001\/archopht.1991.01080050068031","article-title":"Vitreous surgery for idiopathic macular holes. Results of a pilot study","volume":"109","author":"Kelly","year":"1991","journal-title":"Arch Ophthalmol"},{"key":"R6-20250702","first-page":"CD009080","article-title":"Vitrectomy for idiopathic macular hole","volume":"2015","author":"Parravano","year":"2015","journal-title":"Cochrane Database Syst Rev"},{"key":"R7-20250702","doi-asserted-by":"crossref","first-page":"769","DOI":"10.1016\/S0002-9394(00)00358-5","article-title":"Internal limiting membrane removal in the management of full-thickness macular holes","volume":"129","author":"Mester","year":"2000","journal-title":"Am J Ophthalmol"},{"key":"R8-20250702","doi-asserted-by":"crossref","first-page":"2018","DOI":"10.1016\/j.ophtha.2010.02.011","article-title":"Inverted internal limiting membrane flap technique for large macular holes","volume":"117","author":"Michalewska","year":"2010","journal-title":"Ophthalmology"},{"key":"R9-20250702","doi-asserted-by":"crossref","first-page":"118","DOI":"10.1016\/j.ajo.2010.07.007","article-title":"Axial length and outcomes of macular hole surgery assessed by spectral-domain optical coherence tomography","volume":"151","author":"Suda","year":"2011","journal-title":"Am J Ophthalmol"},{"key":"R10-20250702","doi-asserted-by":"crossref","first-page":"1844","DOI":"10.1097\/IAE.0000000000000555","article-title":"Temporal inverted internal limiting membrane flap technique versus classic inverted internal limiting membrane flap technique: a Comparative Study","volume":"35","author":"Michalewska","year":"2015","journal-title":"Retina"},{"key":"R11-20250702","doi-asserted-by":"crossref","first-page":"2183","DOI":"10.1007\/s00417-022-05587-9","article-title":"360\u00b0 inverted internal limiting membrane flap technique for idiopathic macular holes\u2009\u2264\u2009250 \u00b5m,\u2009>\u2009250 and\u2009\u2264\u2009400 \u00b5m, and\u2009>\u2009400\u00a0 \u00b5m","volume":"260","author":"Kastl","year":"2022","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"R12-20250702","doi-asserted-by":"crossref","first-page":"1841","DOI":"10.1007\/s00417-020-04655-2","article-title":"Effects of inverted internal limiting membrane technique and insertion technique on outer retinal restoration associated with glial proliferation in large macular holes","volume":"258","author":"Iwasaki","year":"2020","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"R13-20250702","doi-asserted-by":"crossref","first-page":"664","DOI":"10.1097\/IAE.0000000000000042","article-title":"Inverted internal limiting membrane flap technique for surgical repair of myopic macular holes","volume":"34","author":"Michalewska","year":"2014","journal-title":"Retina"},{"key":"R14-20250702","doi-asserted-by":"crossref","first-page":"752","DOI":"10.1016\/S0002-9394(14)72781-3","article-title":"Reappraisal of biomicroscopic classification of stages of development of a macular hole","volume":"119","author":"Gass","year":"1995","journal-title":"Am J Ophthalmol"},{"key":"R15-20250702","doi-asserted-by":"crossref","first-page":"245","DOI":"10.1136\/bjophthalmol-2017-311770","article-title":"Comparative analysis of large macular hole surgery using an internal limiting membrane insertion versus inverted flap technique","volume":"103","author":"Park","year":"2019","journal-title":"Br J Ophthalmol"},{"key":"R16-20250702","first-page":"1120672119892427","article-title":"Conventional internal limiting membrane peeling versus temporal inverted internal limiting membrane flap for large macular holes","author":"Avci","year":"2019","journal-title":"Eur J Ophthalmol"},{"key":"R17-20250702","doi-asserted-by":"crossref","first-page":"1073","DOI":"10.1007\/s00417-017-3598-9","article-title":"Macular hole closure patterns associated with different internal limiting membrane flap techniques","volume":"255","author":"Rossi","year":"2017","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"R18-20250702","doi-asserted-by":"crossref","first-page":"1465","DOI":"10.1097\/IAE.0000000000002186","article-title":"Surgical outcomes after inverted internal limiting membrane flap versus conventional peeling for very large macular holes","volume":"39","author":"Narayanan","year":"2019","journal-title":"Retina"},{"key":"R19-20250702","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1159\/000343061","article-title":"Early imaging of macular hole closure: a diagnostic technique and its quality for gas-filled eyes with spectral domain optical coherence tomography","volume":"229","author":"Yamashita","year":"2013","journal-title":"Ophthalmologica"},{"key":"R20-20250702","doi-asserted-by":"crossref","first-page":"48","DOI":"10.1159\/000368437","article-title":"Dynamics of macular hole closure in gas-filled eyes within 24 h of surgery observed with swept source optical coherence tomography","volume":"53","author":"Kikushima","year":"2015","journal-title":"Ophthalmic Res"},{"key":"R21-20250702","doi-asserted-by":"crossref","first-page":"473","DOI":"10.1016\/j.ajo.2008.09.020","article-title":"Associations between macular findings by optical coherence tomography and visual outcomes after epiretinal membrane removal","volume":"147","author":"Suh","year":"2009","journal-title":"Am J Ophthalmol"},{"key":"R22-20250702","doi-asserted-by":"crossref","first-page":"775","DOI":"10.1038\/eye.2011.55","article-title":"Fourier-domain optical coherence tomography of eyes with idiopathic epiretinal membrane: correlation between macular morphology and visual function","volume":"25","author":"Pilli","year":"2011","journal-title":"Eye (Lond)"},{"key":"R23-20250702","doi-asserted-by":"crossref","first-page":"3161","DOI":"10.1007\/s00417-022-05676-9","article-title":"Visual improvement and regeneration of retinal layers in eyes with small, medium, and large idiopathic full-thickness macular holes treated with the inverted internal limiting membrane flap technique over a period of 12 months","volume":"260","author":"Bleidi\u00dfel","year":"2022","journal-title":"Graefes Arch Clin Exp Ophthalmol"}],"container-title":["Retina"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1097\/IAE.0000000000004443","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,4]],"date-time":"2026-08-04T15:25:35Z","timestamp":1785857135000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1097\/IAE.0000000000004443"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,7]]},"references-count":23,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/iae.0000000000004443","relation":{},"ISSN":["0275-004X","1539-2864"],"issn-type":[{"value":"0275-004X","type":"print"},{"value":"1539-2864","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,7]]}}}