{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,7,2]],"date-time":"2025-07-02T04:24:33Z","timestamp":1751430273258,"version":"3.41.0"},"reference-count":23,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"7","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,7]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>To quantitatively evaluate hand tremors during retinal vascular cannulation surgery with a microneedle and investigate if a customized passive surgical robot suppresses hand tremors.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>A surgical simulation eye was modified, and an analysis system was used that synchronized the surgical video and accelerometer attached to the tail of the microneedle syringe. A cannulation target mimicking the optic disc and retinal vessels was designed in the bottom of the artificial eye. Two vitreous surgeons used this system to evaluate hand tremor 15 seconds before cannulation and 60 seconds during cannulation with and without the robot.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>Fifteen seconds before cannulation, the mean horizontal, vertical, and combined components of hand tremor were 3.8 \u00b1 1.7, 0.93 \u00b1 0.48, and 4.0 \u00b1 1.7 mG without the robot, decreasing to 3.3 \u00b1 1.6, 0.87 \u00b1 0.52, and 3.5 \u00b1 1.8 mG, respectively, with the robot. Significant reductions were observed in the horizontal (<jats:italic toggle=\"yes\">P<\/jats:italic> = 0.012) and combined components (<jats:italic toggle=\"yes\">P<\/jats:italic> = 0.020). Sixty seconds during cannulation, the mean horizontal, vertical, and combined components of hand tremor were 3.3 \u00b1 1.0, 0.53 \u00b1 0.24, and 3.4 \u00b1 1.0 mG, respectively, without the robot. These components significantly decreased with the robot to 2.2 \u00b1 0.7, 0.40 \u00b1 0.15, and 2.2 \u00b1 0.7 mG, respectively, for all components (<jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.001). Hand tremor decreased significantly by 35% in the combined components during cannulation with the robot.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion:<\/jats:title>\n            <jats:p>The customized passive surgical support robot reduces hand tremor during simulated retinal vascular cannulation surgery.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/iae.0000000000004447","type":"journal-article","created":{"date-parts":[[2025,3,10]],"date-time":"2025-03-10T23:00:11Z","timestamp":1741647611000},"page":"1427-1432","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["EVALUATION OF HAND TREMOR SUPPRESSION USING A PASSIVE SURGICAL SUPPORT ROBOT IN SIMULATED RETINAL VASCULAR CANNULATION"],"prefix":"10.1097","volume":"45","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-6236-6580","authenticated-orcid":false,"given":"Shin","family":"Tanaka","sequence":"first","affiliation":[{"name":"Department of Ophthalmology and Micro-Technology, Yokohama City University, Yokohama City, Japan;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yuta","family":"Taniguchi","sequence":"additional","affiliation":[{"name":"Tokyo Electron Miyagi Ltd., Kurokawa-gun, Miyagi, Japan;"},{"name":"Department of Bioengineering, The University of Tokyo, Tokyo, Japan; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hiroshi","family":"Enaida","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Saga University Faculty of Medicine, Saga, Japan."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kentaro","family":"Nakamura","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology and Micro-Technology, Yokohama City University, Yokohama City, Japan;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hiroaki","family":"Sakai","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Saga University Faculty of Medicine, Saga, Japan."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Soichiro","family":"Yamamoto","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Saga University Faculty of Medicine, Saga, Japan."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shohei","family":"Kitahata","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology and Micro-Technology, Yokohama City University, Yokohama City, Japan;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tatsuya","family":"Inoue","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology and Micro-Technology, Yokohama City University, Yokohama City, Japan;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Toshiro","family":"Yamanaka","sequence":"additional","affiliation":[{"name":"Department of Bioengineering, The University of Tokyo, Tokyo, Japan; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fumihito","family":"Arai","sequence":"additional","affiliation":[{"name":"Department of Bioengineering, The University of Tokyo, Tokyo, Japan; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kazuaki","family":"Kadonosono","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology and Micro-Technology, Yokohama City University, Yokohama City, Japan;"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20250701","doi-asserted-by":"crossref","first-page":"564","DOI":"10.1007\/s004210050635","article-title":"Bilateral organization of physiological tremor in the upper limb","volume":"80","author":"Morrison","year":"1999","journal-title":"Eur J Appl Physiol Occup Physiol"},{"key":"R2-20250701","doi-asserted-by":"crossref","first-page":"3723","DOI":"10.1007\/s00417-022-05718-2","article-title":"Overcoming the impact of physiologic tremors in ophthalmology","volume":"260","author":"Singh","year":"2022","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"R3-20250701","doi-asserted-by":"crossref","first-page":"358","DOI":"10.1001\/archneur.1982.00510180036009","article-title":"A normative study of postural tremor of the hand","volume":"39","author":"Wade","year":"1982","journal-title":"Arch Neurol"},{"key":"R4-20250701","doi-asserted-by":"crossref","first-page":"1195","DOI":"10.1136\/bjophthalmol-2018-313318","article-title":"Robot-assisted tremor control for performance enhancement of retinal microsurgeons","volume":"103","author":"Roizenblatt","year":"2019","journal-title":"Br J Ophthalmol"},{"key":"R5-20250701","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1097\/IIO.0000000000000507","article-title":"Robotics-assisted tools in macular surgery","volume":"64","author":"Kadonosono","year":"2024","journal-title":"Int Ophthalmol Clin"},{"key":"R6-20250701","doi-asserted-by":"crossref","first-page":"5790","DOI":"10.1167\/iovs.11-7327","article-title":"An experimental study of retinal endovascular surgery with a microfabricated needle","volume":"52","author":"Kadonosono","year":"2011","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R7-20250701","doi-asserted-by":"crossref","first-page":"1360","DOI":"10.1038\/s41598-018-19747-7","article-title":"Intra-retinal arterial cannulation using a microneedle for central retinal artery occlusion","volume":"8","author":"Kadonosono","year":"2018","journal-title":"Sci Rep"},{"key":"R8-20250701","doi-asserted-by":"crossref","first-page":"327","DOI":"10.1159\/000489696","article-title":"Retinal endovascular surgery with tissue plasminogen activator injection for central retinal artery occlusion","volume":"9","author":"Takata","year":"2018","journal-title":"Case Rep Ophthalmol"},{"key":"R9-20250701","doi-asserted-by":"crossref","first-page":"1676","DOI":"10.1007\/s10439-018-2053-3","article-title":"In-human robot-assisted retinal vein cannulation, a world first","volume":"46","author":"Gijbels","year":"2018","journal-title":"Ann Biomed Eng"},{"key":"R10-20250701","doi-asserted-by":"crossref","first-page":"e0162037","DOI":"10.1371\/journal.pone.0162037","article-title":"Robotic assisted cannulation of occluded retinal veins","volume":"11","author":"de Smet","year":"2016","journal-title":"PLoS One"},{"key":"R11-20250701","doi-asserted-by":"crossref","first-page":"1538","DOI":"10.1016\/j.ophtha.2009.03.001","article-title":"Robot-assisted vitreoretinal surgery: development of a prototype and feasibility studies in an animal model","volume":"116","author":"Ueta","year":"2009","journal-title":"Ophthalmology"},{"key":"R12-20250701","doi-asserted-by":"crossref","first-page":"2091","DOI":"10.1097\/IAE.0000000000002720","article-title":"Robot-assisted vitreoretinal surgery improves surgical accuracy compared with manual surgery: a randomized trial in a simulated setting","volume":"40","author":"Forslund Jacobsen","year":"2020","journal-title":"Retina"},{"key":"R13-20250701","doi-asserted-by":"crossref","first-page":"e661","DOI":"10.1016\/j.wneu.2018.07.237","article-title":"Intelligent surgeon's arm supporting system iArmS in microscopic neurosurgery utilizing robotic technology","volume":"119","author":"Goto","year":"2018","journal-title":"World Neurosurg"},{"key":"R14-20250701","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1227\/NEU.0b013e318271ee66","article-title":"The concept and feasibility of EXPERT: intelligent armrest using robotics technology","volume":"72","author":"Goto","year":"2013","journal-title":"Neurosurgery"},{"key":"R15-20250701","doi-asserted-by":"crossref","first-page":"515","DOI":"10.1177\/1553350620929864","article-title":"The iArmS robotic armrest prolongs endoscope lens-wiping intervals in endoscopic sinus surgery","volume":"27","author":"Okuda","year":"2020","journal-title":"Surg Innov"},{"key":"R16-20250701","doi-asserted-by":"crossref","first-page":"637","DOI":"10.1007\/s10384-023-01017-3","article-title":"Customization of a passive surgical support robot to specifications for ophthalmic surgery and preliminary evaluation","volume":"67","author":"Yamamoto","year":"2023","journal-title":"Jpn J Ophthalmol"},{"key":"R17-20250701","doi-asserted-by":"crossref","first-page":"2091","DOI":"10.1097\/IAE.0000000000004226","article-title":"Investigation of hand tremor suppression by a customized passive surgical support robot during internal limiting membrane peeling","volume":"44","author":"Yamamoto","year":"2024","journal-title":"Retina"},{"key":"R18-20250701","doi-asserted-by":"crossref","first-page":"e0196131","DOI":"10.1371\/journal.pone.0196131","article-title":"A surgical simulator for peeling the inner limiting membrane during wet conditions","volume":"13","author":"Omata","year":"2018","journal-title":"PLoS One"},{"key":"R19-20250701","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1038\/s41378-022-00417-8","article-title":"A force measurement platform for a vitreoretinal surgical simulator using an artificial eye module integrated with a quartz crystal resonator","volume":"8","author":"Taniguchi","year":"2022","journal-title":"Microsyst Nanoeng"},{"key":"R20-20250701","doi-asserted-by":"crossref","first-page":"1169","DOI":"10.1177\/0018720820916629","article-title":"In situ tremor in vitreoretinal surgery","volume":"63","author":"Li","year":"2021","journal-title":"Hum Factors"},{"key":"R21-20250701","doi-asserted-by":"crossref","first-page":"997","DOI":"10.1007\/s10439-009-9664-7","article-title":"The role of posture, magnification, and grip force on microscopic accuracy","volume":"37","author":"Safwat","year":"2009","journal-title":"Ann Biomed Eng"},{"key":"R22-20250701","doi-asserted-by":"crossref","first-page":"164","DOI":"10.1016\/j.brainres.2010.11.047","article-title":"Finger tremor can be voluntarily reduced during a tracking task","volume":"1370","author":"Daneault","year":"2011","journal-title":"Brain Res"},{"key":"R23-20250701","doi-asserted-by":"crossref","first-page":"19369","DOI":"10.1038\/s41598-023-46267-w","article-title":"Macular vessel density in central retinal artery occlusion with retinal arterial cannulation","volume":"13","author":"Soga","year":"2023","journal-title":"Sci Rep"}],"container-title":["Retina"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/IAE.0000000000004447","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,7,1]],"date-time":"2025-07-01T22:00:13Z","timestamp":1751407213000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/IAE.0000000000004447"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,7]]},"references-count":23,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/iae.0000000000004447","relation":{},"ISSN":["0275-004X","1539-2864"],"issn-type":[{"type":"print","value":"0275-004X"},{"type":"electronic","value":"1539-2864"}],"subject":[],"published":{"date-parts":[[2025,7]]}}}