{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,4]],"date-time":"2026-08-04T16:00:03Z","timestamp":1785859203588,"version":"3.56.0"},"reference-count":26,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"7","license":[{"start":{"date-parts":[[2025,7,1]],"date-time":"2025-07-01T00:00:00Z","timestamp":1751328000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,7]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>To evaluate the surgical outcomes of a novel modified scleral-fixated Rayner intraocular lens (IOL) with Gore-Tex suture.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Method:<\/jats:title>\n                    <jats:p>Retrospective chart review of patients who had sclera fixation Rayner IOL and pars plana vitrectomy using Gore-Tex suture without scleral flap between November 2021 and June 2024 was conducted. Data included best-corrected visual acuity, spherical equivalent, and complications. Difference between postoperative spherical equivalent and preoperative predicted refraction are calculated as the prediction error.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Result:<\/jats:title>\n                    <jats:p>\n                      Hundred and three patients (103 eyes) with a mean age of 64.7 \u00b1 13.0 years are included. Seventy-three patients are male, and best-corrected visual acuity improved from logarithm of minimum angle of resolution 1.12 \u00b1 0.66 (20\/263 Snellen) to 0.50 \u00b1 0.56 (20\/63 Snellen) (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001). The mean postoperative spherical equivalent was \u22121.32 \u00b1 1.49 D, and the mean prediction error was \u22120.81 \u00b1 1.16 D. Refractive outcomes showed 76.7% of patients were within \u00b11.5 D and 92.2% were within \u00b12.5 D of the refractive target. Postoperative complications included transient elevated intraocular pressure (7.77%), transient hypotony (1.94%), cystoid macular edema (6.80%), vitreous hemorrhage (1.94%), stitch exposure (2.91%), and IOL tilt or subluxation (2.91%).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>The novel modified scleral fixation technique was safe with transient and tolerable complications. The study observed an average myopic shift of 0.81 D in refractive outcomes.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/iae.0000000000004451","type":"journal-article","created":{"date-parts":[[2025,3,26]],"date-time":"2025-03-26T12:44:36Z","timestamp":1742993076000},"page":"1339-1346","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":2,"title":["SURGICAL AND REFRACTIVE OUTCOMES OF A NOVEL MODIFIED SCLERA-FIXATED RAYNER INTRAOCULAR LENS USING GORE-TEX SUTURE"],"prefix":"10.1097","volume":"45","author":[{"given":"Chung-Hao","family":"Hsiao","sequence":"first","affiliation":[{"name":"Department of Ophthalmology, Taichung Veterans General Hospital, Taichung, Taiwan; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuan-Shao","family":"Cheng","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Taichung Veterans General Hospital, Taichung, Taiwan; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wen-Jung","family":"Lo","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Taichung Veterans General Hospital, Taichung, Taiwan; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hung-Ju","family":"Chen","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Taichung Veterans General Hospital, Taichung, Taiwan; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chia-Jen","family":"Chang","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Taichung Veterans General Hospital, Taichung, Taiwan; and"},{"name":"Department of Post-Baccalaureate Medicine, National Chung Hsing University, Taichung, Taiwan."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20250702","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1177\/2474126417690650","article-title":"Scleral-fixated intraocular lenses: past and present","volume":"1","author":"Stem","year":"2017","journal-title":"J vitreoretinal Dis"},{"key":"R2-20250702","doi-asserted-by":"crossref","first-page":"1404","DOI":"10.4103\/ijo.IJO_2192_20","article-title":"Anterior chamber intraocular lens - an effective alternative in traumatic and surgical aphakia in the era of scleral-fixated intraocular lens","volume":"69","author":"Mahapatra","year":"2021","journal-title":"Indian J Ophthalmol"},{"key":"R3-20250702","doi-asserted-by":"crossref","first-page":"1875","DOI":"10.1038\/s41433-019-0759-6","article-title":"Outcomes and complications of iris-fixated intraocular lenses in cases with inadequate capsular support and complex ophthalmic history","volume":"34","author":"Dzhaber","year":"2020","journal-title":"Eye"},{"key":"R4-20250702","doi-asserted-by":"crossref","first-page":"452","DOI":"10.1177\/2474126420978870","article-title":"Long-term stability of sutured scleral fixation of a posterior chamber intraocular lens with 10-0 polypropylene for more than 30 years","volume":"5","author":"Kokame","year":"2021","journal-title":"J Vitreoretinal Dis"},{"key":"R5-20250702","doi-asserted-by":"crossref","first-page":"1377","DOI":"10.1097\/IAE.0000000000001692","article-title":"Combined pars plana vitrectomy and scleral fixation of an intraocular lens using gore-tex suture: one-Year outcomes","volume":"38","author":"Khan","year":"2018","journal-title":"Retina"},{"key":"R6-20250702","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1016\/j.ophtha.2013.08.043","article-title":"Sutureless 27-gauge needle-guided intrascleral intraocular lens implantation with lamellar scleral dissection","volume":"121","author":"Yamane","year":"2014","journal-title":"Ophthalmology"},{"key":"R7-20250702","doi-asserted-by":"crossref","first-page":"9349323","DOI":"10.1155\/2021\/9349323","article-title":"Scleral fixation of Akreos AO60 intraocular lens using gore-tex suture: an eye on visual outcomes and postoperative complications","volume":"2021","author":"Leuzinger-Dias","year":"2021","journal-title":"J Ophthalmol"},{"key":"R8-20250702","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1016\/j.ajo.2018.01.034","article-title":"Long-term outcome of pars plana vitrectomy and sutured scleral-fixated posterior chamber intraocular lens implantation or repositioning","volume":"189","author":"Kokame","year":"2018","journal-title":"Am J Ophthalmol"},{"key":"R9-20250702","doi-asserted-by":"crossref","first-page":"308","DOI":"10.1016\/j.ajo.2005.09.012","article-title":"Long-term outcome of combined pars plana vitrectomy and scleral fixated sutured posterior chamber intraocular lens implantation","volume":"141","author":"Vote","year":"2006","journal-title":"Am J Ophthalmol"},{"key":"R10-20250702","doi-asserted-by":"crossref","first-page":"371","DOI":"10.1016\/j.ajo.2007.05.014","article-title":"Long-term safety and functional outcome of combined pars plana vitrectomy and scleral-fixated sutured posterior chamber lens implantation","volume":"144","author":"Bading","year":"2007","journal-title":"Am J Ophthalmol"},{"key":"R11-20250702","doi-asserted-by":"crossref","first-page":"1480","DOI":"10.1097\/j.jcrs.0000000000000309","article-title":"Intraoperative performance and long-term postoperative outcomes after scleral fixation of IOLs with polytetrafluoroethylene suture","volume":"46","author":"Bhojwani","year":"2020","journal-title":"J Cataract Refractive Surg"},{"key":"R12-20250702","doi-asserted-by":"crossref","first-page":"907","DOI":"10.1016\/j.athoracsur.2010.08.038","article-title":"Half-leaflet suspension with a thin Gore-Tex suture for aortic leaflet prolapse","volume":"91","author":"Shimamoto","year":"2011","journal-title":"Ann Thorac Surg"},{"key":"R13-20250702","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1177\/2474126419895691","article-title":"Outcomes and complications of concurrent pars plana vitrectomy and scleral-fixated intraocular lens placement using gore-tex suture","volume":"4","author":"Day","year":"2020","journal-title":"J Vitreoretinal Dis"},{"key":"R14-20250702","doi-asserted-by":"crossref","first-page":"2145","DOI":"10.2147\/OPTH.S174211","article-title":"Clinical outcomes of 4-point scleral fixated 1-piece hydrophobic acrylic equiconvex intraocular lens using polytetrafluoroethylene suture","volume":"12","author":"Patel","year":"2018","journal-title":"Clin Ophthalmol"},{"key":"R15-20250702","doi-asserted-by":"crossref","first-page":"1477","DOI":"10.1097\/IAE.0000000000000233","article-title":"Scleral fixation of posterior chamber intraocular lenses using gore-tex suture with concurrent 23-gauge pars plana vitrectomy","volume":"34","author":"Khan","year":"2014","journal-title":"Retina"},{"key":"R16-20250702","doi-asserted-by":"crossref","first-page":"548","DOI":"10.1016\/j.oret.2019.02.012","article-title":"Refractive outcomes after pars plana vitrectomy and scleral fixated intraocular lens with gore-tex suture","volume":"3","author":"Su","year":"2019","journal-title":"Ophthalmol Retina"},{"key":"R17-20250702","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1186\/s12886-022-02759-3","article-title":"A novel surgical approach for fixation of a posterior chamber intraocular lens of Rayner 620 H with Gore-Tex suture","volume":"23","author":"Wang","year":"2023","journal-title":"BMC Ophthalmol"},{"key":"R18-20250702","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1007\/s00417-008-0926-0","article-title":"Resolving the clinical acuity categories \u201chand motion\u201d and \u201ccounting fingers\u201d using the Freiburg Visual Acuity Test (FrACT)","volume":"247","author":"Lange","year":"2009","journal-title":"Graefe's archive Clin Exp Ophthalmol"},{"key":"R19-20250702","doi-asserted-by":"crossref","first-page":"638","DOI":"10.1136\/bjophthalmol-2015-306839","article-title":"Scleral fixation of intraocular lenses using Gore-Tex suture: clinical outcomes and safety profile","volume":"100","author":"Khan","year":"2016","journal-title":"Br J Ophthalmol"},{"key":"R20-20250702","doi-asserted-by":"crossref","first-page":"15793","DOI":"10.1038\/s41598-021-95428-2","article-title":"Scleral fixation using a hydrophilic four-haptic lens and polytetrafluoroethylene suture","volume":"11","author":"Junqueira","year":"2021","journal-title":"Scientific Rep"},{"key":"R21-20250702","doi-asserted-by":"crossref","first-page":"4431","DOI":"10.2147\/OPTH.S282094","article-title":"Refractive outcomes of four-point scleral fixation of Akreos AO60 intraocular lens using gore-tex suture","volume":"14","author":"Patel","year":"2020","journal-title":"Clin Ophthalmol"},{"key":"R22-20250702","doi-asserted-by":"crossref","first-page":"971758","DOI":"10.1155\/2013\/971758","article-title":"Inflammation and macular oedema after pars plana vitrectomy","volume":"2013","author":"Romano","year":"2013","journal-title":"Mediators Inflamm"},{"key":"R23-20250702","doi-asserted-by":"crossref","first-page":"1849","DOI":"10.1007\/s10792-021-02182-5","article-title":"Surgical outcomes and prognostic factors in traumatic retinal detachment following closed-globe injuries","volume":"42","author":"Hsiao","year":"2022","journal-title":"Int Ophthalmol"},{"key":"R24-20250702","doi-asserted-by":"crossref","first-page":"1279","DOI":"10.2147\/OPTH.S157462","article-title":"In-and-out technique for intraocular lens scleral fixation","volume":"12","author":"Choi","year":"2018","journal-title":"Clin Ophthalmol"},{"key":"R25-20250702","doi-asserted-by":"crossref","first-page":"2125","DOI":"10.1007\/s00417-020-04721-9","article-title":"Refractive outcomes and accuracy of IOL power calculation with the SRK\/T formula for sutured, scleral-fixated Akreos AO60 intraocular lenses","volume":"258","author":"Ohr","year":"2020","journal-title":"Graefe's Archive Clin Exp Ophthalmol"},{"key":"R26-20250702","doi-asserted-by":"crossref","first-page":"95","DOI":"10.1016\/j.tjo.2013.06.001","article-title":"Myopic shift of sulcus suture-fixated posterior chamber intraocular lenses","volume":"3","author":"Huang","year":"2013","journal-title":"Taiwan J Ophthalmol"}],"container-title":["Retina"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1097\/IAE.0000000000004451","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,4]],"date-time":"2026-08-04T15:07:35Z","timestamp":1785856055000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1097\/IAE.0000000000004451"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,7]]},"references-count":26,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/iae.0000000000004451","relation":{},"ISSN":["0275-004X","1539-2864"],"issn-type":[{"value":"0275-004X","type":"print"},{"value":"1539-2864","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,7]]}}}