{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,22]],"date-time":"2026-06-22T23:59:34Z","timestamp":1782172774826,"version":"3.54.5"},"reference-count":15,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"11","license":[{"start":{"date-parts":[[2025,11,1]],"date-time":"2025-11-01T00:00:00Z","timestamp":1761955200000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,11]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>To describe a technique for implanting capsular hooks made from a 7-0 polypropylene sutures, used for sutureless scleral fixation of the capsular bag in cases of lens subluxation.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>A 26-G needle was used to guide the 7-0 polypropylene suture into the eye. The suture was then extracted and thermally shaped into a hook. A needle holder clamped the built-in suture needle, allowing it to pass through the superficial layer of the sclera at the puncture site. Both hands coordinated the subsequent procedure: The suture was pulled externally, while the hook was advanced internally to vertically engage with the capsular bag at the site of continuous curvilinear capsulorhexis.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>This technique was applied to 11 eyes of 11 patients. The best-corrected visual acuity improved from a preoperative mean of 1.15 \u00b1 0.39 logarithm of the minimum angle of resolution [logMAR] (Snellen 20\/206) to 0.18 \u00b1 0.15 logMAR (Snellen 20\/29) at the final follow-up. Throughout the follow-up period, the capsular hook exerted stable vertical traction on the capsular bag at the site of the continuous curvilinear capsulorhexis without slippage.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>The capsular hooks made from 7-0 polypropylene sutures provide an effective alternative method for stabilizing the capsular bag in cases of moderate to severe lens subluxation.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/iae.0000000000004481","type":"journal-article","created":{"date-parts":[[2025,4,8]],"date-time":"2025-04-08T16:00:56Z","timestamp":1744128056000},"page":"2187-2191","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":2,"title":["Implantable Capsular Hook Technique for Sutureless Scleral Fixation of the Capsular Bag in Lens Subluxation"],"prefix":"10.1097","volume":"45","author":[{"ORCID":"https:\/\/orcid.org\/0009-0003-8734-119X","authenticated-orcid":false,"given":"Chunming","family":"Chen","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yan","family":"Shao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hong","family":"Zhong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chengyao","family":"Qin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zehao","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wenxiu","family":"Sun","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Min","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20251021","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1097\/ICU.0b013e3282f2ccc8","article-title":"Surgical strategies for the management of zonular compromise","volume":"19","author":"Blecher","year":"2008","journal-title":"Curr Opin Ophthalmol"},{"key":"R2-20251021","doi-asserted-by":"crossref","first-page":"315","DOI":"10.1016\/S0886-3350(02)01534-1","article-title":"Efficacy of a capsular tension ring for phacoemulsification in eyes with zonular dialysis","volume":"29","author":"Jacob","year":"2003","journal-title":"J Cataract Refract Surg"},{"key":"R3-20251021","doi-asserted-by":"crossref","first-page":"1091","DOI":"10.1111\/ceo.13975","article-title":"Management of the subluxated crystalline lens: a review","volume":"49","author":"Chee","year":"2021","journal-title":"Clin Exp Ophthalmol"},{"key":"R4-20251021","doi-asserted-by":"crossref","first-page":"1668","DOI":"10.1016\/S0886-3350(03)00238-4","article-title":"Modified capsular tension ring for patients with congenital loss of zonular support","volume":"29","author":"Cionni","year":"2003","journal-title":"J Cataract Refract Surg"},{"key":"R5-20251021","doi-asserted-by":"crossref","first-page":"1477","DOI":"10.1136\/bjo.2007.131169","article-title":"Cionni endocapsular ring implantation in Marfan's Syndrome","volume":"91","author":"Bahar","year":"2007","journal-title":"Br J Ophthalmol"},{"key":"R6-20251021","doi-asserted-by":"crossref","first-page":"2653","DOI":"10.1007\/s10792-017-0746-5","article-title":"Double-flanged-haptic and capsular tension ring or segment for sutureless fixation in zonular instability","volume":"38","author":"Canabrava","year":"2018","journal-title":"Int Ophthalmol"},{"key":"R7-20251021","doi-asserted-by":"crossref","first-page":"333","DOI":"10.1097\/j.jcrs.0000000000000116","article-title":"Novel double-flanged technique for managing Marfan syndrome and microspherophakia","volume":"46","author":"Canabrava","year":"2020","journal-title":"J Cataract Refract Surg"},{"key":"R8-20251021","doi-asserted-by":"crossref","first-page":"1299","DOI":"10.1016\/S0886-3350(98)80218-6","article-title":"Management of profound zonular dialysis or weakness with a new endocapsular ring designed for scleral fixation","volume":"24","author":"Cionni","year":"1998","journal-title":"J Cataract Refract Surg"},{"key":"R9-20251021","doi-asserted-by":"crossref","first-page":"1372","DOI":"10.1016\/j.jcrs.2009.02.046","article-title":"Capsule anchor to manage subluxated lenses: initial clinical experience","volume":"35","author":"Assia","year":"2009","journal-title":"J Cataract Refract Surg"},{"key":"R10-20251021","doi-asserted-by":"crossref","first-page":"1088","DOI":"10.1097\/j.jcrs.0000000000000985","article-title":"Flanged iris hook for capsular bag stabilization","volume":"48","author":"Soyler","year":"2022","journal-title":"J Cataract Refract Surg"},{"key":"R11-20251021","doi-asserted-by":"crossref","first-page":"118","DOI":"10.1097\/j.jcrs.0000000000000838","article-title":"Sutureless technique for repositioning and scleral fixation of the capsular bag-intraocular lens complex with permanent use of iris retractors","volume":"48","author":"Krix-Jachym","year":"2022","journal-title":"J Cataract Refract Surg"},{"key":"R12-20251021","doi-asserted-by":"crossref","first-page":"1386","DOI":"10.1016\/j.jcrs.2011.06.015","article-title":"Repositioning and scleral fixation of subluxated lenses using a T-shaped capsule stabilization hook","volume":"37","author":"Yaguchi","year":"2011","journal-title":"J Cataract Refract Surg"},{"key":"R13-20251021","doi-asserted-by":"crossref","first-page":"1958","DOI":"10.1016\/j.jcrs.2014.10.009","article-title":"Glued capsular hook: technique for fibrin glue-assisted sutureless transscleral fixation of the capsular bag in subluxated cataracts and intraocular lenses","volume":"40","author":"Jacob","year":"2014","journal-title":"J Cataract Refract Surg"},{"key":"R14-20251021","doi-asserted-by":"crossref","first-page":"S33","DOI":"10.1097\/IAE.0000000000002425","article-title":"Intrascleral fixation of implantable polypropylene capsular hook(s): a sutureless technique to fixate the capsular bag for intraocular lens implantation in subluxated lenses","volume":"39","author":"Ou","year":"2019","journal-title":"Retina"},{"key":"R15-20251021","doi-asserted-by":"crossref","first-page":"295","DOI":"10.1097\/j.jcrs.0000000000001367","article-title":"Attaining the optimal flange technique for transscleral capsular bag stabilization using iris hooks","volume":"50","author":"Schlatter","year":"2024","journal-title":"J Cataract Refract Surg"}],"container-title":["Retina"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/IAE.0000000000004481","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,21]],"date-time":"2025-10-21T19:00:46Z","timestamp":1761073246000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/IAE.0000000000004481"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,11]]},"references-count":15,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/iae.0000000000004481","relation":{},"ISSN":["0275-004X","1539-2864"],"issn-type":[{"value":"0275-004X","type":"print"},{"value":"1539-2864","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,11]]}}}