{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,14]],"date-time":"2025-11-14T15:04:14Z","timestamp":1763132654999,"version":"3.45.0"},"reference-count":24,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"12","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,12]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>This study investigated the use of human amniotic membrane graft transplantation for treating recurrent large macular holes in highly myopic patients, particularly in cases resistant to standard surgical methods.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>\n                      Seven eyes from six highly myopic patients with recurrent large macular holes (&gt;400\n                      <jats:italic toggle=\"yes\">\u00b5<\/jats:italic>\n                      m) underwent human amniotic membrane transplantation supported by perfluorocarbon liquid and ophthalmic viscoelastic devices. All patients had previously undergone pars plana vitrectomy with internal limiting membrane peeling. The human amniotic membrane graft, sized to cover the macular area, was carefully positioned with perfluorocarbon liquid and ophthalmic viscoelastic device assistance to enhance surgical control and prevent graft displacement.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>Complete macular hole closure was achieved in most cases. Best-corrected visual acuity was either preserved or improved, with no complications such as retinal detachment or graft displacement. The modified technique also reduced the need for prolonged prone positioning, minimizing postoperative discomfort for patients.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Human amniotic membrane graft transplantation with perfluorocarbon liquid and ophthalmic viscoelastic device is a safe and effective method for managing large, recurrent macular holes in highly myopic eyes. This technique enhances graft handling, simplifies surgery, and achieves high closure rates with stable visual outcomes, offering a promising solution when conventional methods are inadequate.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/iae.0000000000004556","type":"journal-article","created":{"date-parts":[[2025,7,2]],"date-time":"2025-07-02T17:00:13Z","timestamp":1751475613000},"page":"2413-2419","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Human Amniotic Membrane Graft Transplantation for Treating Recurrent High Myopic Large Macular Hole"],"prefix":"10.1097","volume":"45","author":[{"given":"Chunya","family":"Kang","sequence":"first","affiliation":[{"name":"Department of Education, Keelung Chang Gung Memorial Hospital, Keelung, Taiwan;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eugene Yu-Chuan","family":"Kang","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Chang Gung Memorial Hospital, Linkou Medical Center, Taoyuan, Taiwan;"},{"name":"College of Medicine, Chang Gung University, Taoyuan, Taiwan;"},{"name":"Department of Ophthalmology, Vagelos College of Physicians and Surgeons, Columbia University Irving Medical Center, New York, New York; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hung-Da","family":"Chou","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Chang Gung Memorial Hospital, Linkou Medical Center, Taoyuan, Taiwan;"},{"name":"College of Medicine, Chang Gung University, Taoyuan, Taiwan;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nan-Kai","family":"Wang","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Chang Gung Memorial Hospital, Linkou Medical Center, Taoyuan, Taiwan;"},{"name":"College of Medicine, Chang Gung University, Taoyuan, Taiwan;"},{"name":"Department of Ophthalmology, Vagelos College of Physicians and Surgeons, Columbia University Irving Medical Center, New York, New York; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kuan-Jen","family":"Chen","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Chang Gung Memorial Hospital, Linkou Medical Center, Taoyuan, Taiwan;"},{"name":"College of Medicine, Chang Gung University, Taoyuan, Taiwan;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yih-Shiou","family":"Hwang","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Chang Gung Memorial Hospital, Linkou Medical Center, Taoyuan, Taiwan;"},{"name":"College of Medicine, Chang Gung University, Taoyuan, Taiwan;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wei-Chi","family":"Wu","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Chang Gung Memorial Hospital, Linkou Medical Center, Taoyuan, Taiwan;"},{"name":"College of Medicine, Chang Gung University, Taoyuan, Taiwan;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chi-Chun","family":"Lai","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Chang Gung Memorial Hospital, Linkou Medical Center, Taoyuan, Taiwan;"},{"name":"College of Medicine, Chang Gung University, Taoyuan, Taiwan;"},{"name":"Department of Ophthalmology, Keelung Chang Gung Memorial Hospital, Keelung, Taiwan."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20251114","doi-asserted-by":"crossref","first-page":"299","DOI":"10.1001\/jamaophthalmol.2016.5870","article-title":"Incidence of and risk factors for developing idiopathic macular hole among a diverse group of patients throughout the United States","volume":"135","author":"Ali","year":"2017","journal-title":"JAMA Ophthalmol"},{"key":"R2-20251114","doi-asserted-by":"crossref","first-page":"62","DOI":"10.1007\/s40135-020-00231-3","article-title":"Management of large or recurrent macular holes","volume":"8","author":"Robles-Holmes","year":"2020","journal-title":"Curr Ophthalmol Rep"},{"key":"R3-20251114","doi-asserted-by":"crossref","first-page":"1263","DOI":"10.1097\/IAE.0000000000002020","article-title":"The current surgical management of large, recurrent, or persistent macular holes","volume":"38","author":"Tam","year":"2018","journal-title":"Retina"},{"key":"R4-20251114","doi-asserted-by":"crossref","first-page":"3230695","DOI":"10.1155\/2019\/3230695","article-title":"Macular hole in myopic eyes: a narrative review of the current surgical techniques","volume":"2019","author":"De Giacinto","year":"2019","journal-title":"J Ophthalmol"},{"key":"R5-20251114","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1007\/s00417-013-2555-5","article-title":"Anatomical and visual outcomes in high myopic macular hole (HM-MH) without retinal detachment: a review","volume":"252","author":"Alkabes","year":"2014","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"R6-20251114","doi-asserted-by":"crossref","first-page":"1946","DOI":"10.1097\/IAE.0000000000002699","article-title":"Human amniotic membrane to close recurrent, high myopic macular holes in pathologic myopia with axial length of \u226530 mm","volume":"40","author":"Caporossi","year":"2020","journal-title":"Retina"},{"key":"R7-20251114","doi-asserted-by":"crossref","first-page":"1015","DOI":"10.1136\/bjo.87.8.1015","article-title":"Types of macular hole closure and their clinical implications","volume":"87","author":"Kang","year":"2003","journal-title":"Br J Ophthalmol"},{"key":"R8-20251114","doi-asserted-by":"crossref","first-page":"116","DOI":"10.1186\/s12886-020-01393-1","article-title":"Sub-perfluoro-n-octane injection of ocular viscoelastic device assisted inverted internal limiting membrane flap for macular hole retinal detachment surgery: a novel technique","volume":"20","author":"Lai","year":"2020","journal-title":"BMC Ophthalmol"},{"key":"R9-20251114","doi-asserted-by":"crossref","first-page":"296","DOI":"10.1016\/j.ajo.2020.09.023","article-title":"Nasal or temporal internal limiting membrane flap assisted by sub-perfluorocarbon viscoelastic injection for macular hole repair","volume":"223","author":"Chou","year":"2021","journal-title":"Am J Ophthalmol"},{"key":"R10-20251114","doi-asserted-by":"crossref","first-page":"190","DOI":"10.1186\/s12886-025-03969-1","article-title":"Sub-perfluorocarbon ophthalmic viscoelastic injection (SPOT) technique for macular hole retinal detachment surgery","volume":"25","author":"Chou","year":"2025","journal-title":"BMC Ophthalmol"},{"key":"R11-20251114","doi-asserted-by":"crossref","first-page":"95","DOI":"10.1016\/j.oret.2021.10.009","article-title":"Inaccurate measurements confound the study of myopic macular hole","volume":"6","author":"Scoles","year":"2022","journal-title":"Ophthalmol Retina"},{"key":"R12-20251114","doi-asserted-by":"crossref","first-page":"921","DOI":"10.1097\/IAE.0000000000001252","article-title":"Recurrent macular holes in the era of small-gauge vitrectomy: a review of incidence, risk factors, and outcomes","volume":"37","author":"Abbey","year":"2017","journal-title":"Retina"},{"key":"R13-20251114","doi-asserted-by":"crossref","first-page":"S95","DOI":"10.1097\/IAE.0000000000002320","article-title":"A human amniotic membrane plug to promote retinal breaks repair and recurrent macular hole closure","volume":"39","author":"Rizzo","year":"2019","journal-title":"Retina"},{"key":"R14-20251114","doi-asserted-by":"crossref","first-page":"1479","DOI":"10.1097\/IAE.0000000000003505","article-title":"Amniotic membrane graft for the treatment of large refractory macular hole","volume":"42","author":"Khaqan","year":"2022","journal-title":"Retina"},{"key":"R15-20251114","doi-asserted-by":"crossref","first-page":"431","DOI":"10.1016\/j.oret.2022.01.006","article-title":"Human amniotic membrane plug for chronic or persistent macular holes","volume":"6","author":"Bamberger","year":"2022","journal-title":"Ophthalmol Retina"},{"key":"R16-20251114","doi-asserted-by":"crossref","first-page":"2411","DOI":"10.2147\/OPTH.S272060","article-title":"Human amniotic membrane plug for macular holes coexisting with rhegmatogenous retinal detachment","volume":"14","author":"Abouhussein","year":"2020","journal-title":"Clin Ophthalmol"},{"key":"R17-20251114","doi-asserted-by":"crossref","first-page":"613","DOI":"10.3928\/23258160-20240411-04","article-title":"A surgical approach for managing refractory macular holes using the human amniotic membrane patch technique","volume":"55","author":"Chen","year":"2024","journal-title":"Ophthalmic Surg Lasers Imaging Retina"},{"key":"R18-20251114","doi-asserted-by":"crossref","first-page":"98","DOI":"10.1001\/archophthalmol.2007.2","article-title":"Displacement of retained subfoveal perfluorocarbon liquid after vitreoretinal surgery","volume":"126","author":"Le Tien","year":"2008","journal-title":"Arch Ophthalmol"},{"key":"R19-20251114","doi-asserted-by":"crossref","first-page":"894991","DOI":"10.3389\/fmed.2022.894991","article-title":"A novel subfoveal perfluorocarbon liquid removal technique combining a 25-gauge retrobulbar needle with a built-in 30-gauge needle","volume":"9","author":"Yang","year":"2022","journal-title":"Front Med"},{"key":"R20-20251114","doi-asserted-by":"crossref","first-page":"1891","DOI":"10.1097\/IAE.0000000000004220","article-title":"Perfluorocarbon liquid use during vitrectomy for macula-off retinal detachment has no impact on macular folds and metamorphopsia","volume":"44","author":"Wurtz","year":"2024","journal-title":"Retina"},{"key":"R21-20251114","doi-asserted-by":"crossref","first-page":"358","DOI":"10.1186\/s12886-020-01600-z","article-title":"Outcomes of a postoperative perfluorocarbon liquid tamponade for complex retinal detachments: 12 years of experience in southern Thailand","volume":"20","author":"Bhurayanontachai","year":"2020","journal-title":"BMC Ophthalmol"},{"key":"R22-20251114","doi-asserted-by":"crossref","first-page":"392","DOI":"10.3341\/kjo.2013.27.5.392","article-title":"Surgical removal of retained subfoveal perfluorocarbon liquid through a therapeutic macular hole with intravitreal PFCL injection and gas tamponade","volume":"27","author":"Kim","year":"2013","journal-title":"Korean J Ophthalmol"},{"key":"R23-20251114","doi-asserted-by":"crossref","first-page":"9157518","DOI":"10.1155\/2020\/9157518","article-title":"Comparison between cryopreserved and dehydrated human amniotic membrane graft in treating challenging cases with macular hole and macular hole retinal detachment","volume":"2020","author":"Huang","year":"2020","journal-title":"J Ophthalmol"},{"key":"R24-20251114","doi-asserted-by":"crossref","first-page":"442","DOI":"10.1159\/000509339","article-title":"A human amniotic membrane plug to treat persistent macular hole","volume":"11","author":"Ventre","year":"2020","journal-title":"Case Rep Ophthalmol"}],"container-title":["Retina"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/IAE.0000000000004556","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,11,14]],"date-time":"2025-11-14T15:00:40Z","timestamp":1763132440000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/IAE.0000000000004556"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,12]]},"references-count":24,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/iae.0000000000004556","relation":{},"ISSN":["0275-004X","1539-2864"],"issn-type":[{"type":"print","value":"0275-004X"},{"type":"electronic","value":"1539-2864"}],"subject":[],"published":{"date-parts":[[2025,12]]}}}