{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,19]],"date-time":"2026-11-19T18:01:29Z","timestamp":1795111289685,"version":"4.10.3"},"reference-count":14,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"12","license":[{"start":{"date-parts":[[2025,12,1]],"date-time":"2025-12-01T00:00:00Z","timestamp":1764547200000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,12]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>This study describes a novel loop and sliding knot technique for the scleral fixation of the Akreos Adapt AO intraocular lens.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>A 27-G needle was inserted into the eye from two ipsilateral fixation sites, and passed through the intraocular lens eyelet, exiting from the same limbus incision. The suture was pulled out and inserted into the needle to form a loop. A 26-G needle guided the suture to pass through the superficial sclera between the 2 fixation sites. Part of the suture was pulled out and tied to the free suture to form a sliding knot. The knot was then buried in the scleral tunnel.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>A total of 12 patients (12 eyes) underwent this technique. The logarithm of the minimum angle of resolution (logMAR) for preoperative corrected visual acuity was 0.75 \u00b1 0.62 (Snellen 20\/112), which improved to 0.25 \u00b1 0.24 (Snellen 20\/35) at the final follow-up. The mean postoperative posterior chamber intraocular lens tilt was 2.64 \u00b1 1.28\u00b0. There were no cases of pupillary capture or suture-related complications during the follow-up period.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>The loop and sliding knot technique offers a simple and minimally invasive method for the four-point fixation of the Akreos Adapt AO intraocular lens.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/iae.0000000000004600","type":"journal-article","created":{"date-parts":[[2025,7,7]],"date-time":"2025-07-07T17:00:10Z","timestamp":1751907610000},"page":"2420-2423","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["A Loop and Sliding Knot Technique for Scleral Fixation of Akreos Adapt AO Intraocular Lens"],"prefix":"10.1097","volume":"45","author":[{"ORCID":"https:\/\/orcid.org\/0009-0003-8734-119X","authenticated-orcid":false,"given":"Chunming","family":"Chen","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hong","family":"Zhong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yan","family":"Shao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wenxiu","family":"Sun","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zehao","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chengyao","family":"Qin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Min","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20251114","doi-asserted-by":"crossref","first-page":"630","DOI":"10.1016\/j.jfo.2017.11.029","article-title":"Secondary intraocular lens implantation with absence of capsular support: scleral versus Iris fixation","volume":"41","author":"Nehme","year":"2018","journal-title":"J Fr Ophtalmol"},{"key":"R2-20251114","doi-asserted-by":"crossref","first-page":"15793","DOI":"10.1038\/s41598-021-95428-2","article-title":"Scleral fixation using a hydrophilic four-haptic lens and polytetrafluoroethylene suture","volume":"11","author":"Junqueira","year":"2021","journal-title":"Sci Rep"},{"key":"R3-20251114","doi-asserted-by":"crossref","first-page":"324","DOI":"10.1097\/IAE.0000000000003960","article-title":"Contribution factors of effective lens position, tilt, and decentration during flanged scleral fixation of intraocular lens: a model eye study","volume":"44","author":"Park","year":"2024","journal-title":"Retina"},{"key":"R4-20251114","doi-asserted-by":"crossref","first-page":"2362","DOI":"10.1097\/IAE.0000000000001595","article-title":"Novel surgical approach for fixation of a posterior chamber intraocular lens using gore-tex suture","volume":"37","author":"Mantopoulos","year":"2017","journal-title":"Retina"},{"key":"R5-20251114","doi-asserted-by":"crossref","first-page":"1421","DOI":"10.1016\/j.jcrs.2018.08.008","article-title":"New use of 8-0 polypropylene suture for four-point scleral fixation of secondary intraocular lenses","volume":"44","author":"John","year":"2018","journal-title":"J Cataract Refract Surg"},{"key":"R6-20251114","doi-asserted-by":"crossref","first-page":"1055","DOI":"10.1038\/s41433-018-0018-2","article-title":"Clinical outcomes of combined pars plana vitrectomy and trans-scleral 4-point suture fixation of a foldable intraocular lens","volume":"32","author":"Goel","year":"2018","journal-title":"Eye (Lond)"},{"key":"R7-20251114","doi-asserted-by":"crossref","first-page":"211","DOI":"10.1016\/j.jcrs.2015.10.068","article-title":"Small-incision 4-point scleral suture fixation of a foldable hydrophilic acrylic intraocular lens in the absence of capsule support","volume":"42","author":"Terveen","year":"2016","journal-title":"J Cataract Refract Surg"},{"key":"R8-20251114","doi-asserted-by":"crossref","first-page":"265","DOI":"10.1097\/j.jcrs.0000000000000310","article-title":"Scleral fixation of a 4-eyelet foldable intraocular lens in patients with aphakia using a 4-flanged technique","volume":"47","author":"Canabrava","year":"2021","journal-title":"J Cataract Refract Surg"},{"key":"R9-20251114","doi-asserted-by":"crossref","first-page":"S21","DOI":"10.1097\/IAE.0000000000002138","article-title":"Minimally invasive Ab interno four-point scleral fixation of intraocular lens","volume":"39","author":"Hadayer","year":"2019","journal-title":"Retina"},{"key":"R10-20251114","doi-asserted-by":"crossref","first-page":"1227","DOI":"10.1097\/j.jcrs.0000000000000600","article-title":"Modification of intraocular lens insertion using 4-flanged fixation with a standard cartridge and a 2.4 mm corneal incision in eyes with no capsular support","volume":"47","author":"Mahler","year":"2021","journal-title":"J Cataract Refract Surg"},{"key":"R11-20251114","doi-asserted-by":"crossref","first-page":"1","DOI":"10.3341\/kjo.2007.21.1.1","article-title":"Comparison of surgically induced astigmatisms after clear corneal incisions of different sizes","volume":"21","author":"Moon","year":"2007","journal-title":"Korean J Ophthalmol"},{"key":"R12-20251114","doi-asserted-by":"crossref","first-page":"295","DOI":"10.1097\/j.jcrs.0000000000001367","article-title":"Attaining the optimal flange technique for transscleral capsular bag stabilization using Iris hooks","volume":"50","author":"Schlatter","year":"2024","journal-title":"J Cataract Refract Surg"},{"key":"R13-20251114","doi-asserted-by":"crossref","first-page":"353","DOI":"10.1097\/IAE.0000000000004130","article-title":"A novel custom bent 27-gauge needle-guided suture snare technique for scleral fixation of posterior chamber intraocular lenses","volume":"45","author":"Chen","year":"2025","journal-title":"Retina"},{"key":"R14-20251114","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1016\/j.ajo.2018.01.034","article-title":"Long-term outcome of pars plana vitrectomy and sutured scleral-fixated posterior chamber intraocular lens implantation or repositioning","volume":"189","author":"Kokame","year":"2018","journal-title":"Am J Ophthalmol"}],"container-title":["Retina"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1097\/IAE.0000000000004600","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,6]],"date-time":"2026-08-06T18:32:49Z","timestamp":1786041169000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1097\/IAE.0000000000004600"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,12]]},"references-count":14,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/iae.0000000000004600","relation":{},"ISSN":["0275-004X","1539-2864"],"issn-type":[{"value":"0275-004X","type":"print"},{"value":"1539-2864","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,12]]}}}