{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,14]],"date-time":"2025-11-14T15:04:17Z","timestamp":1763132657474,"version":"3.45.0"},"reference-count":30,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"12","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,12]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>To report outcomes of a novel technique involving the injection of a dispersive viscoelastic device on to inverted temporal internal limiting membrane flap under air for macular hole (MH) closure, without requiring postoperative head positioning.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>A temporal internal limiting membrane flap was created in all patients and inverted over the MH with perfluorocarbon liquid. After a fluid\u2013air exchange, a perfluorocarbon liquid\u2013air exchange was done. Afterward, a dispersive viscoelastic agent was applied around the inverted flap under air, covering an area of two-to-three\u2013disk diameters. An air\u2013sulfur hexafluoride exchange was then performed, and the sclerotomies were closed. No head positioning was advised postoperatively. Data on preoperative MH size, best-corrected visual acuity, MH closure rate, and closure pattern were collected.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      The study included 114 eyes from 106 patients. Initial MH closure was achieved in 112 eyes (98.2%), with two cases closed after a second surgery. U-shaped closure occurred in 71.9%, V-shaped in 20.1%, and W-shaped in 8%. Significant best-corrected visual acuity improvement was observed (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001), with no significant change in intraocular pressure (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.881).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>This technique enhances flap stabilization, facilitates MH closure, and eliminates the need for postoperative head positioning, leading to favorable anatomical and functional outcomes with improved patient comfort.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/iae.0000000000004609","type":"journal-article","created":{"date-parts":[[2025,7,23]],"date-time":"2025-07-23T20:00:25Z","timestamp":1753300825000},"page":"2344-2352","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["OUTCOMES OF A NOVEL TECHNIQUE THAT DOES NOT REQUIRE HEAD POSITION IN MACULAR HOLE SURGERY"],"prefix":"10.1097","volume":"45","author":[{"given":"Sevim Ay\u00e7a","family":"Seyyar","sequence":"first","affiliation":[{"name":"Department of Ophthalmology, Gaziantep University School of Medicine, Gaziantep, Turkey; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"O\u011fuzhan","family":"Sayg\u0131l\u0131","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Gaziantep University School of Medicine, Gaziantep, Turkey; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ay\u015feg\u00fcl","family":"\u00c7\u00f6mez","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Kahramanmara\u015f S\u00fct\u00e7\u00fc \u0130mam University School of Medicine, Kahramanmara\u015f, Turkey."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Erhan","family":"Kanat","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Gaziantep University School of Medicine, Gaziantep, Turkey; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Veysel","family":"Do\u011fru","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Gaziantep University School of Medicine, Gaziantep, Turkey; and"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20251114","doi-asserted-by":"crossref","first-page":"654","DOI":"10.1001\/archopht.1991.01080050068031","article-title":"Vitreous surgery for idiopathic macular holes. Results of a pilot study","volume":"109","author":"Kelly","year":"1991","journal-title":"Arch Ophthalmol"},{"key":"R2-20251114","doi-asserted-by":"crossref","first-page":"S9","DOI":"10.1097\/01.iae.0000236463.38888.e1","article-title":"Macular holes: the latest in current management","volume":"26","author":"Williams","year":"2006","journal-title":"Retina"},{"key":"R3-20251114","doi-asserted-by":"crossref","first-page":"179","DOI":"10.1016\/j.ajo.2016.06.041","article-title":"Extent of internal limiting membrane peeling and its impact on macular hole surgery outcomes: a randomized trial","volume":"169","author":"Bae","year":"2016","journal-title":"Am J Ophthalmol"},{"key":"R4-20251114","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1001\/archopht.120.1.29","article-title":"Anatomical outcomes of surgery for idiopathic macular hole as determined by optical coherence tomography","volume":"120","author":"Ip","year":"2002","journal-title":"Arch Ophthalmol"},{"key":"R5-20251114","doi-asserted-by":"crossref","first-page":"2018","DOI":"10.1016\/j.ophtha.2010.02.011","article-title":"Inverted internal limiting membrane flap technique for large macular holes","volume":"117","author":"Michalewska","year":"2010","journal-title":"Ophthalmology"},{"key":"R6-20251114","doi-asserted-by":"crossref","first-page":"S73","DOI":"10.1097\/IAE.0000000000001985","article-title":"Internal limiting membrane peeling versus inverted flap technique for treatment of full-thickness macular holes: a comparative study in a large series of patients","volume":"38","author":"Rizzo","year":"2018","journal-title":"Retina"},{"key":"R7-20251114","doi-asserted-by":"crossref","first-page":"236","DOI":"10.3928\/23258160-20180329-04","article-title":"Comparative evaluation of standard ILM peel with inverted ILM flap technique in large macular holes: a prospective, randomized study","volume":"49","author":"Manasa","year":"2018","journal-title":"Ophthalmic Surg Lasers Imaging Retina"},{"key":"R8-20251114","doi-asserted-by":"crossref","first-page":"2206","DOI":"10.1038\/s41433-020-01228-9","article-title":"Silicone oil tamponade for persistent macular holes","volume":"35","author":"Li","year":"2021","journal-title":"Eye (Lond)."},{"key":"R9-20251114","doi-asserted-by":"crossref","first-page":"200","DOI":"10.1097\/IAE.0000000000003657","article-title":"Excessive gliosis after vitrectomy for the highly myopic macular hole: a spectral domain optical coherence tomography study","volume":"43","author":"Ye","year":"2023","journal-title":"Retina"},{"key":"R10-20251114","doi-asserted-by":"crossref","first-page":"317","DOI":"10.1097\/IAE.0000000000002853","article-title":"Perfluorocarbon liquid-assisted inverted internal limiting membrane flap technique versus internal limiting membrane peeling for highly myopic macular hole retinal detachment","volume":"41","author":"Gu","year":"2021","journal-title":"Retina"},{"key":"R11-20251114","doi-asserted-by":"crossref","first-page":"373","DOI":"10.1097\/00006982-199616050-00002","article-title":"Intraocular tamponade duration and success of macular hole surgery","volume":"16","author":"Thompson","year":"1996","journal-title":"Retina"},{"key":"R12-20251114","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1038\/eye.2000.78","article-title":"Surgery for full-thickness macular holes with short-duration prone posturing: results of a pilot study","volume":"14","author":"Ellis","year":"2000","journal-title":"Eye (Lond)."},{"key":"R13-20251114","doi-asserted-by":"crossref","first-page":"289","DOI":"10.1111\/j.1600-0420.2005.00462.x","article-title":"Duration of face-down positioning after macular hole surgery: a comparison between 1 week and 3 days","volume":"83","author":"Krohn","year":"2005","journal-title":"Acta Ophthalmol Scand"},{"key":"R14-20251114","doi-asserted-by":"crossref","first-page":"609","DOI":"10.1097\/IAE.0b013e318207ce93","article-title":"Surgical outcomes of idiopathic macular hole repair with limited postoperative positioning","volume":"31","author":"Wu","year":"2011","journal-title":"Retina"},{"key":"R15-20251114","doi-asserted-by":"crossref","first-page":"1320","DOI":"10.1136\/bjo.85.11.1320","article-title":"Macular hole surgery using silicone oil tamponade","volume":"85","author":"Karia","year":"2001","journal-title":"Br J Ophthalmol"},{"key":"R16-20251114","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1016\/S0002-9394(03)00094-1","article-title":"Observation of idiopathic full-thickness macular hole closure in early postoperative period as evaluated by optical coherence tomography","volume":"136","author":"Sato","year":"2003","journal-title":"Am J Ophthalmol"},{"key":"R17-20251114","doi-asserted-by":"crossref","first-page":"1069","DOI":"10.2147\/OPTH.S284620","article-title":"Spotlight on the internal limiting membrane technique for macular holes: current perspectives","volume":"16","author":"Caporossi","year":"2022","journal-title":"Clin Ophthalmol"},{"key":"R18-20251114","doi-asserted-by":"crossref","first-page":"120","DOI":"10.3928\/23258160-20241015-01","article-title":"Macular hole surgery without postoperative head positioning: a technique of viscoelastic device injection covering the temporal internal limiting membrane flap","volume":"56","author":"Sayg\u0131l\u0131","year":"2025","journal-title":"Ophthalmic Surg Lasers Imaging Retina"},{"key":"R19-20251114","doi-asserted-by":"crossref","first-page":"1844","DOI":"10.1097\/IAE.0000000000000555","article-title":"Temporal inverted internal limiting membrane flap technique versus classic inverted internal limiting membrane flap technique: a comparative study","volume":"35","author":"Michalewska","year":"2015","journal-title":"Retina"},{"key":"R20-20251114","doi-asserted-by":"crossref","first-page":"1045","DOI":"10.3928\/23258160-20151027-10","article-title":"Pedicle internal limiting membrane transposition flap technique for refractory macular hole","volume":"46","author":"Gekka","year":"2015","journal-title":"Ophthalmic Surg Lasers Imaging Retina"},{"key":"R21-20251114","doi-asserted-by":"crossref","first-page":"834","DOI":"10.1097\/IAE.0000000000000931","article-title":"Modification of the inverted internal limiting membrane flap technique for the treatment of chronic and large macular holes","volume":"36","author":"Andrew","year":"2016","journal-title":"Retina"},{"key":"R22-20251114","doi-asserted-by":"crossref","first-page":"e402","DOI":"10.1111\/aos.15717","article-title":"Internal limiting membrane flap made easy: flap manipulation on viscoelastic-coated retinal surface","volume":"102","author":"Kwak","year":"2024","journal-title":"Acta Ophthalmol"},{"key":"R23-20251114","doi-asserted-by":"crossref","first-page":"296","DOI":"10.1016\/j.ajo.2020.09.023","article-title":"Nasal or temporal internal limiting membrane flap assisted by sub-perfluorocarbon viscoelastic injection for macular hole repair","volume":"223","author":"Chou","year":"2021","journal-title":"Am J Ophthalmol"},{"key":"R24-20251114","doi-asserted-by":"crossref","first-page":"861","DOI":"10.1016\/j.ajo.2013.12.028","article-title":"Autologous transplantation of the internal limiting membrane for refractory macular holes","volume":"157","author":"Morizane","year":"2014","journal-title":"Am J Ophthalmol"},{"key":"R25-20251114","first-page":"11206721211016976","article-title":"Viscoelastic-assisted inverted cover and free ILM flap techniques","author":"Romano","year":"2021","journal-title":"Eur J Ophthalmol"},{"key":"R26-20251114","doi-asserted-by":"crossref","first-page":"3395","DOI":"10.1007\/s00417-023-06196-w","article-title":"Internal limiting membrane flap with viscoelastic device for lamellar hole surgery with no postoperative positioning","volume":"261","author":"Berco","year":"2023","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"R27-20251114","doi-asserted-by":"crossref","first-page":"688","DOI":"10.1097\/IAE.0000000000002850","article-title":"Macular hole closure without endotamponade application","volume":"43","author":"Stopa","year":"2023","journal-title":"Retina"},{"key":"R28-20251114","doi-asserted-by":"crossref","first-page":"548","DOI":"10.1097\/IAE.0000000000003350","article-title":"Inverted internal limiting membrane flap technique without postoperative face-down positioning for macular hole repair","volume":"42","author":"Ruparelia","year":"2022","journal-title":"Retina"},{"key":"R29-20251114","doi-asserted-by":"crossref","first-page":"621","DOI":"10.1016\/S0002-9394(99)00200-7","article-title":"Optical coherence tomography of successfully repaired idiopathic macular holes","volume":"128","author":"Imai","year":"1999","journal-title":"Am J Ophthalmol"},{"key":"R30-20251114","doi-asserted-by":"crossref","first-page":"1015","DOI":"10.1136\/bjo.87.8.1015","article-title":"Types of macular hole closure and their clinical implications","volume":"87","author":"Kang","year":"2003","journal-title":"Br J Ophthalmol"}],"container-title":["Retina"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/IAE.0000000000004609","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,11,14]],"date-time":"2025-11-14T15:00:42Z","timestamp":1763132442000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/IAE.0000000000004609"}},"subtitle":["Application of Viscoelastic on an Inverted Internal Limiting Membrane Flap Under Air"],"short-title":[],"issued":{"date-parts":[[2025,12]]},"references-count":30,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/iae.0000000000004609","relation":{},"ISSN":["0275-004X","1539-2864"],"issn-type":[{"type":"print","value":"0275-004X"},{"type":"electronic","value":"1539-2864"}],"subject":[],"published":{"date-parts":[[2025,12]]}}}