{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,24]],"date-time":"2026-03-24T19:25:21Z","timestamp":1774380321266,"version":"3.50.1"},"reference-count":15,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,4]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>To characterize intraocular lenses (IOL) position, IOL stability and iris dynamics in eyes with sutureless intrascleral haptic fixated intraocular lenses (SIS-IOLs).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>This nonconsecutive observational study used ultrasound biomicroscopy to better characterize SIS-IOLs. We included individuals who had SIS-IOL surgery between October 2014 and October 2018. We excluded individuals younger than18 years and those with active uveitis, advanced glaucoma, known ocular syndrome(s), and those with repeated SIS-IOL dislocations before the time of the ultrasound evaluation. Serial ultrasound biomicroscopy were performed in both the seated\/supine positions and IOL position and stability were described as our primary outcome. As a secondary outcome, iris mobility was evaluated through dynamic ultrasound biomicroscopy in both the SIS-IOL and posterior chamber IOL (surgery between 2001 and 2019) groups.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Analysis of ultrasound biomicroscopy of 22 SIS-IOLs and 10 posterior chamber IOLs, showed that on average, SIS-IOLs were positioned significantly more posteriorly than standard posterior chamber IOLs (aqueous depth = 0.59 vs. 0.48 mm;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.00006)). Over time, SIS-IOLs demonstrated a slight posterior displacement of the IOL (0.18 mm shift posteriorly). Finally, in eyes with SIS-IOLs there was a high degree of iris mobility when compared with the posterior chamber IOL group (Fleiss Kappa 0.887).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>This study provides ultrasound-based evidence demonstrating a more posterior IOL position with increased iris mobility in eyes with an SIS-IOL. These data provide valuable information which may inform surgeons as they consider IOL selection and surgical technique.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/iae.0000000000004740","type":"journal-article","created":{"date-parts":[[2026,3,24]],"date-time":"2026-03-24T16:07:30Z","timestamp":1774368450000},"page":"698-704","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["CHARACTERIZING INTRAOCULAR LENS POSITION, STABILITY, AND IRIS MOBILITY IN EYES THAT HAVE UNDERGONE SUTURELESS INTRASCLERAL HAPTIC FIXATION"],"prefix":"10.1097","volume":"46","author":[{"given":"Matthew G. J.","family":"Trese","sequence":"first","affiliation":[{"name":"Associated Retinal Consultants, Corewell Health, Department of Ophthalmology, Royal Oak, Michigan; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Laurie Lau-Sickon","family":"CDOS","sequence":"additional","affiliation":[{"name":"Associated Retinal Consultants, Corewell Health, Department of Ophthalmology, Royal Oak, Michigan; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nathan D.","family":"Farley","sequence":"additional","affiliation":[{"name":"Associated Retinal Consultants, Corewell Health, Department of Ophthalmology, Royal Oak, Michigan; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Maria A.","family":"Woodward","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Kellogg Eye Institute, University of Michigan, Ann Arbor, Michigan."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lisa J.","family":"Faia","sequence":"additional","affiliation":[{"name":"Associated Retinal Consultants, Corewell Health, Department of Ophthalmology, Royal Oak, Michigan; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sandeep","family":"Randhawa","sequence":"additional","affiliation":[{"name":"Associated Retinal Consultants, Corewell Health, Department of Ophthalmology, Royal Oak, Michigan; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tarek S.","family":"Hassan","sequence":"additional","affiliation":[{"name":"Associated Retinal Consultants, Corewell Health, Department of Ophthalmology, Royal Oak, Michigan; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"George A.","family":"Williams","sequence":"additional","affiliation":[{"name":"Associated Retinal Consultants, Corewell Health, Department of Ophthalmology, Royal Oak, Michigan; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2781-7152","authenticated-orcid":false,"given":"Jeremy D.","family":"Wolfe","sequence":"additional","affiliation":[{"name":"Associated Retinal Consultants, Corewell Health, Department of Ophthalmology, Royal Oak, Michigan; and"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20260324","doi-asserted-by":"crossref","first-page":"301","DOI":"10.1016\/S0886-3350(02)01526-2","article-title":"Comparison of secondary implantation of flexible open-loop anterior chamber and scleral-fixated posterior chamber intraocular lenses","volume":"29","author":"Evereklioglu","year":"2003","journal-title":"J Cataract Refract Surg"},{"key":"R2-20260324","doi-asserted-by":"crossref","first-page":"965","DOI":"10.1016\/j.oret.2023.07.008","article-title":"Trends in secondary intraocular lens surgery among vitreoretinal surgeons","volume":"7","author":"Kaufmann","year":"2023","journal-title":"Ophthalmol Retina"},{"key":"R3-20260324","doi-asserted-by":"crossref","first-page":"1234","DOI":"10.1016\/j.ophtha.2020.03.005","article-title":"Intraocular lens implantation in the absence of zonular support: an outcomes and safety update: a report by the American academy of ophthalmology","volume":"127","author":"Shen","year":"2020","journal-title":"Ophthalmology"},{"key":"R4-20260324","doi-asserted-by":"crossref","first-page":"1851","DOI":"10.1016\/j.jcrs.2007.07.013","article-title":"Sutureless intrascleral posterior chamber intraocular lens fixation","volume":"33","author":"Gabor","year":"2007","journal-title":"J Cataract Refract Surg"},{"key":"R5-20260324","doi-asserted-by":"crossref","first-page":"210","DOI":"10.1097\/ICU.0000000000000474","article-title":"Sutureless transscleral fixation of secondary intraocular lenses","volume":"29","author":"Nudleman","year":"2018","journal-title":"Curr Opin Ophthalmol"},{"key":"R6-20260324","doi-asserted-by":"crossref","first-page":"50","DOI":"10.1097\/ICU.0000000000000632","article-title":"Scleral fixation of intraocular lenses","volume":"31","author":"Jacob","year":"2020","journal-title":"Curr Opin Ophthalmol"},{"key":"R7-20260324","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/s00417-014-2834-9","article-title":"Sutureless scleral fixation of intraocular lenses: outcomes of two approaches. The 2014 yasuo tano memorial lecture","volume":"253","author":"Abbey","year":"2015","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"R8-20260324","doi-asserted-by":"crossref","first-page":"368","DOI":"10.1016\/j.jcrs.2007.10.031","article-title":"Sources of error in intraocular lens power calculation","volume":"34","author":"Norrby","year":"2008","journal-title":"J Cataract Refract Surg"},{"key":"R9-20260324","doi-asserted-by":"crossref","first-page":"822","DOI":"10.1097\/IAE.0000000000002916","article-title":"Refractive outcomes after sutureless intrascleral fixation of intraocular lens with pars plana vitrectomy","volume":"41","author":"Lee","year":"2021","journal-title":"Retina"},{"key":"R10-20260324","doi-asserted-by":"crossref","first-page":"664","DOI":"10.1016\/j.jcrs.2005.02.027","article-title":"Intraoperative floppy iris syndrome associated with tamsulosin","volume":"31","author":"Chang","year":"2005","journal-title":"J Cataract Refract Surg"},{"key":"R11-20260324","doi-asserted-by":"crossref","first-page":"839","DOI":"10.1016\/S0002-9394(02)01386-7","article-title":"Ultrasound biomicroscopy in uveitis-glaucoma-hyphema syndrome","volume":"133","author":"Piette","year":"2002","journal-title":"Am J Ophthalmol"},{"key":"R12-20260324","doi-asserted-by":"crossref","first-page":"S31","DOI":"10.1097\/IAE.0000000000001941","article-title":"Structural analysis and comprehensive surgical outcomes of the sutureless intrascleral fixation of secondary intraocular lenses in human eyes","volume":"38","author":"Todorich","year":"2018","journal-title":"Retina"},{"key":"R13-20260324","doi-asserted-by":"crossref","first-page":"1445","DOI":"10.1016\/j.jcrs.2009.04.027","article-title":"Complications of sulcus placement of single-piece acrylic intraocular lenses: recommendations for backup IOL implantation following posterior capsule rupture","volume":"35","author":"Chang","year":"2009","journal-title":"J Cataract Refract Surg"},{"key":"R14-20260324","doi-asserted-by":"crossref","first-page":"1459","DOI":"10.1016\/j.jcrs.2009.05.005","article-title":"Solving intraocular lens-related pigment dispersion syndrome with repositioning of primary sulcus implanted single-piece IOL in the capsular bag","volume":"35","author":"Kohnen","year":"2009","journal-title":"J Cataract Refract Surg"},{"key":"R15-20260324","doi-asserted-by":"crossref","first-page":"2215","DOI":"10.1016\/j.jcrs.2015.10.057","article-title":"Laser iridotomy to treat uveitis-glaucoma-hyphema syndrome secondary to reverse pupillary block in sulcus-placed intraocular lenses: case series","volume":"41","author":"Singh","year":"2015","journal-title":"J Cataract Refract Surg"}],"container-title":["Retina"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/IAE.0000000000004740","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,24]],"date-time":"2026-03-24T16:07:32Z","timestamp":1774368452000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/IAE.0000000000004740"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4]]},"references-count":15,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/iae.0000000000004740","relation":{},"ISSN":["0275-004X","1539-2864"],"issn-type":[{"value":"0275-004X","type":"print"},{"value":"1539-2864","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4]]}}}