{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,3]],"date-time":"2026-08-03T23:47:28Z","timestamp":1785800848124,"version":"3.56.0"},"reference-count":16,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","funder":[{"DOI":"10.13039\/501100012166","name":"National Key R&D Program of China","doi-asserted-by":"crossref","award":["2022YFC2404203"],"award-info":[{"award-number":["2022YFC2404203"]}],"id":[{"id":"10.13039\/501100012166","id-type":"DOI","asserted-by":"crossref"}]},{"name":"Shanghai Sailing Program","award":["23YF1445400"],"award-info":[{"award-number":["23YF1445400"]}]}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,4]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>The aim of this study was to evaluate the feasibility and clinical utility of a commercially available microscope-integrated intraoperative optical coherence tomography (MI-OCT) system during scleral-sutured fixation of intraocular lenses (IOLs).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>Scleral-sutured IOL fixation was performed in 18 eyes using the Zeiss Rescan 700 MI-OCT system. Intraoperative optical coherence tomography images were captured, and the utility of MI-OCT in the procedure was assessed.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Eighteen eyes from 18 patients underwent scleral-sutured IOL fixation using the MI-OCT system. The system provided clear anterior segment images in all cases. In 15 cases, the captured images provided crucial information for evaluating IOL tilt in at least one meridian (0\u00b0 or 90\u00b0). In the remaining cases, failure to assess tilt was attributed to iris asymmetry (2 cases) or a very posteriorly positioned IOL (1 case) in both horizontal and vertical meridians. In 16 cases with at least 3 months of follow-up, spherical equivalent significantly improved (preoperative: +5.72 \u00b1 6.97 D; postoperative: \u22121.57 \u00b1 1.77 D;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.004), while corneal endothelial cell density, best-corrected visual acuity, and intraocular pressure remained stable. Postoperative Pentacam HR imaging demonstrated a mean IOL tilt of 0.98 \u00b1 0.93\u00b0 horizontally and 1.67 \u00b1 1.37\u00b0 vertically.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>The commercial MI-OCT system enabled intraoperative evaluation of IOL tilt during scleral-sutured IOL fixation, although its utility was limited in cases involving asymmetric iris or posteriorly located IOLs. Future systems with wider and deeper scanning ranges and the ability to reference the anterior chamber angle may enhance performance.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/iae.0000000000004741","type":"journal-article","created":{"date-parts":[[2025,11,24]],"date-time":"2025-11-24T22:00:12Z","timestamp":1764021612000},"page":"705-712","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["MICROSCOPE-INTEGRATED INTRAOPERATIVE OPTICAL COHERENCE TOMOGRAPHY FOR INTRAOCULAR LENS TILT EVALUATION DURING SCLERAL-SUTURE FIXATION"],"prefix":"10.1097","volume":"46","author":[{"given":"Sigeng","family":"Lin","sequence":"first","affiliation":[{"name":"Department of Ophthalmology and Vision Science, Eye and ENT Hospital, Fudan University, Shanghai, People's Republic of China;"},{"name":"Key Laboratory of Myopia of State Health Ministry, and Key Laboratory of Visual Impairment and Restoration of Shanghai, Shanghai, People's Republic of China; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kaicheng","family":"Wu","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology and Vision Science, Eye and ENT Hospital, Fudan University, Shanghai, People's Republic of China;"},{"name":"Key Laboratory of Myopia of State Health Ministry, and Key Laboratory of Visual Impairment and Restoration of Shanghai, Shanghai, People's Republic of China; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jiemei","family":"Shi","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology and Vision Science, Eye and ENT Hospital, Fudan University, Shanghai, People's Republic of China;"},{"name":"Key Laboratory of Myopia of State Health Ministry, and Key Laboratory of Visual Impairment and Restoration of Shanghai, Shanghai, People's Republic of China; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hongmei","family":"Zhao","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology and Vision Science, Eye and ENT Hospital, Fudan University, Shanghai, People's Republic of China;"},{"name":"Key Laboratory of Myopia of State Health Ministry, and Key Laboratory of Visual Impairment and Restoration of Shanghai, Shanghai, People's Republic of China; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaojing","family":"Huang","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology,Shanghai Pudong New Area Gongli Hospital, Shanghai, People's Republic of China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chunhui","family":"Jiang","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology and Vision Science, Eye and ENT Hospital, Fudan University, Shanghai, People's Republic of China;"},{"name":"Key Laboratory of Myopia of State Health Ministry, and Key Laboratory of Visual Impairment and Restoration of Shanghai, Shanghai, People's Republic of China; and"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20260324","doi-asserted-by":"crossref","first-page":"840","DOI":"10.1016\/S0161-6420(02)02000-6","article-title":"Intraocular lens implantation in the absence of capsular support","volume":"110","author":"Wagoner","year":"2003","journal-title":"Ophthalmology"},{"key":"R2-20260324","doi-asserted-by":"crossref","first-page":"180","DOI":"10.1016\/j.ajoc.2018.02.025","article-title":"Adjustments of haptics length for tilted intraocular lens after intrascleral fixation","volume":"10","author":"Kurimori","year":"2018","journal-title":"Am J Ophthalmol Case Rep"},{"key":"R3-20260324","doi-asserted-by":"crossref","first-page":"406","DOI":"10.1016\/j.ajo.2010.09.013","article-title":"Evaluation of intraocular lens tilt with anterior segment optical coherence tomography","volume":"151","author":"Kumar","year":"2011","journal-title":"Am J Ophthalmol"},{"key":"R4-20260324","doi-asserted-by":"crossref","first-page":"48","DOI":"10.1016\/j.ophtha.2014.07.032","article-title":"Long-term assessment of tilt of glued intraocular lenses: an optical coherence tomography analysis 5 years after surgery","volume":"122","author":"Kumar","year":"2015","journal-title":"Ophthalmology"},{"key":"R5-20260324","doi-asserted-by":"crossref","first-page":"2089","DOI":"10.1097\/IAE.0000000000003799","article-title":"Scleral suture intraocular lens fixation under microscope\u2013intraoperative optical coherence tomography","volume":"43","author":"Shi","year":"2023","journal-title":"Retina"},{"key":"R6-20260324","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1016\/j.ajo.2021.10.006","article-title":"In-the-Bag versus ciliary sulcus secondary intraocular lens implantation for pediatric aphakia: a prospective comparative study","volume":"236","author":"Liu","year":"2022","journal-title":"Am J Ophthalmol"},{"key":"R7-20260324","doi-asserted-by":"crossref","first-page":"308","DOI":"10.1016\/j.survophthal.2020.07.001","article-title":"Intraoperative optical coherence tomography in anterior segment surgery","volume":"66","author":"Titiyal","year":"2021","journal-title":"Surv Ophthalmol"},{"key":"R8-20260324","doi-asserted-by":"crossref","first-page":"999","DOI":"10.1016\/j.ajo.2014.07.034","article-title":"The prospective intraoperative and perioperative ophthalmic ImagiNg with optical CoherEncE TomogRaphy (PIONEER) study: 2-year results","volume":"158","author":"Ehlers","year":"2014","journal-title":"Am J Ophthalmol"},{"key":"R9-20260324","doi-asserted-by":"crossref","first-page":"643","DOI":"10.3109\/02713683.2015.1050742","article-title":"Microscope integrated intraoperative spectral domain optical coherence tomography for cataract surgery: uses and applications","volume":"41","author":"Das","year":"2016","journal-title":"Curr Eye Res"},{"key":"R10-20260324","doi-asserted-by":"crossref","first-page":"5196","DOI":"10.1167\/iovs.13-11991","article-title":"Predicting the postoperative intraocular lens position using continuous intraoperative optical coherence tomography measurements","volume":"54","author":"Hirnschall","year":"2013","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R11-20260324","doi-asserted-by":"crossref","first-page":"1310","DOI":"10.1111\/ceo.13862","article-title":"Real-time optical coherence tomography-guided scleral flap creation for intrascleral haptic fixation of posterior chamber intraocular lens","volume":"48","author":"Agarwal","year":"2020","journal-title":"Clin Exp Ophthalmol"},{"key":"R12-20260324","doi-asserted-by":"crossref","first-page":"1308","DOI":"10.1097\/j.jcrs.0000000000000615","article-title":"Adjustment of intraocular lens tilt during intrascleral fixation assisted by intraoperative OCT","volume":"47","author":"Fukumoto","year":"2021","journal-title":"J Cataract Refract Surg"},{"key":"R13-20260324","doi-asserted-by":"crossref","first-page":"271","DOI":"10.1186\/s12886-023-03020-1","article-title":"Comparison of sutureless intrascleral fixation and sutured scleral fixation for the treatment of dislocated intraocular lenses","volume":"23","author":"Zhang","year":"2023","journal-title":"BMC Ophthalmol"},{"key":"R14-20260324","doi-asserted-by":"crossref","first-page":"473","DOI":"10.1111\/j.1442-9071.2005.01064.x","article-title":"Iris ischaemic changes and visual outcome after acute primary angle closure","volume":"33","author":"Loon","year":"2005","journal-title":"Clin Exp Ophthalmol"},{"key":"R15-20260324","doi-asserted-by":"crossref","first-page":"103541","DOI":"10.1016\/j.pdpdt.2023.103541","article-title":"Comparison of both eyes anterior segment structures of patients with unilateral blunt trauma","volume":"42","author":"Mesen","year":"2023","journal-title":"Photodiagnosis Photodyn Ther"},{"key":"R16-20260324","doi-asserted-by":"crossref","first-page":"846","DOI":"10.1364\/BOE.477386","article-title":"Surgical microscope integrated MHz SS-OCT with live volumetric visualization","volume":"14","author":"Britten","year":"2023","journal-title":"Biomed Opt Express"}],"container-title":["Retina"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/IAE.0000000000004741","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,24]],"date-time":"2026-03-24T16:07:20Z","timestamp":1774368440000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/IAE.0000000000004741"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4]]},"references-count":16,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/iae.0000000000004741","relation":{},"ISSN":["0275-004X","1539-2864"],"issn-type":[{"value":"0275-004X","type":"print"},{"value":"1539-2864","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4]]}}}