{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T20:09:02Z","timestamp":1792786142580,"version":"4.5.0"},"reference-count":12,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","funder":[{"name":"UCSD Vision Research Center Core Grant","award":["P30EY022589"],"award-info":[{"award-number":["P30EY022589"]}]},{"name":"NIH","award":["R01EY033847"],"award-info":[{"award-number":["R01EY033847"]}]},{"name":"Research to Prevent Blindness","id":[{"id":"https:\/\/ror.org\/04drjs621","id-type":"ROR","asserted-by":"crossref"}]},{"name":"UCSD Jacobs Retina Center","id":[{"id":"https:\/\/ror.org\/02vxbm786","id-type":"ROR","asserted-by":"crossref"}]}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,5]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>Optical coherence tomography angiography is widely used to detect choroidal neovascularization in retinal diseases, but acquiring high-density raster scans can prolong acquisition time and increase motion artifacts due to patient fatigue. This study evaluates whether the 250 kHz ultrahigh-speed mode (3\u00d7 faster than baseline) reduces scan time and motion artifacts while maintaining image quality compared with the FDA-approved 125 kHz mode.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>Fifty-eight eyes underwent 10\u00b0\u00d710\u00b0 fovea-centered optical coherence tomography angiography imaging using both modes. In 38 choroidal neovascularization eyes, AngioTool was used to analyze vascular metrics. In 20 nonchoroidal neovascularization eyes, superficial foveal avascular zone area was measured using ImageJ. Two masked retina specialists graded paired images for image quality, motion artifacts, and clinical diagnosis. Acquisition time was recorded.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      The 250 kHz mode reduced acquisition time by 43% (17.5 \u00b1 9.0 seconds vs. 33.6 \u00b1 20.7 seconds,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.00001). Image quality and motion artifacts favored the 250 kHz mode. Clinical diagnosis was rated similarly across modes. Quantitative metrics, including vessel area, junctions, lacunarity, and foveal avascular zone area, showed no significant differences (all\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &gt; 0.1).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>This is the first intraindividual comparison of Heidelberg's 250 kHz and 125 kHz optical coherence tomography angiography modes. The findings demonstrate that ultrahigh-speed scanning can enhance efficiency and image quality without compromising diagnostic or quantitative utility, highlighting its potential clinical impact pending Food and Drug Administration approval.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/iae.0000000000004751","type":"journal-article","created":{"date-parts":[[2025,12,26]],"date-time":"2025-12-26T21:00:21Z","timestamp":1766782821000},"page":"829-835","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":2,"title":["COMPARISON OF ULTRAHIGH-SPEED 250 kHz OCTA WITH HIGH-SPEED 125 kHz MODE USING HEIDELBERG SPECTRALIS SHIFT"],"prefix":"10.1097","volume":"46","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8701-3917","authenticated-orcid":false,"given":"Mohamed Sherif","family":"Morsy","sequence":"first","affiliation":[{"name":"Department of Ophthalmology, Jacobs Retina Center, Shiley Eye Institute, University of California San Diego, La Jolla, CA; and"},{"name":"Viterbi Family Department of Ophthalmology and Shiley Eye Institute, University of California San Diego, La Jolla, CA."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nehal Nailesh","family":"Mehta","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Jacobs Retina Center, Shiley Eye Institute, University of California San Diego, La Jolla, CA; and"},{"name":"Viterbi Family Department of Ophthalmology and Shiley Eye Institute, University of California San Diego, La Jolla, CA."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amr L.","family":"Ali","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Jacobs Retina Center, Shiley Eye Institute, University of California San Diego, La Jolla, CA; and"},{"name":"Viterbi Family Department of Ophthalmology and Shiley Eye Institute, University of California San Diego, La Jolla, CA."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anna","family":"Heinke","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Jacobs Retina Center, Shiley Eye Institute, University of California San Diego, La Jolla, CA; and"},{"name":"Viterbi Family Department of Ophthalmology and Shiley Eye Institute, University of California San Diego, La Jolla, CA."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dirk-Uwe","family":"Bartsch","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Jacobs Retina Center, Shiley Eye Institute, University of California San Diego, La Jolla, CA; and"},{"name":"Viterbi Family Department of Ophthalmology and Shiley Eye Institute, University of California San Diego, La Jolla, CA."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lingyun","family":"Cheng","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Jacobs Retina Center, Shiley Eye Institute, University of California San Diego, La Jolla, CA; and"},{"name":"Viterbi Family Department of Ophthalmology and Shiley Eye Institute, University of California San Diego, La Jolla, CA."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9979-2500","authenticated-orcid":false,"given":"William R.","family":"Freeman","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Jacobs Retina Center, Shiley Eye Institute, University of California San Diego, La Jolla, CA; and"},{"name":"Viterbi Family Department of Ophthalmology and Shiley Eye Institute, University of California San Diego, La Jolla, CA."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20260915","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1186\/s40942-015-0005-8","article-title":"A review of optical coherence tomography angiography (OCTA)","volume":"1","author":"de Carlo","year":"2015","journal-title":"Int J Retina Vitreous"},{"key":"R2-20260915","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1001\/jamaophthalmol.2014.3616","article-title":"Retinal vascular layers imaged by fluorescein angiography and optical coherence tomography angiography","volume":"133","author":"Spaide","year":"2015","journal-title":"JAMA Ophthalmol"},{"key":"R3-20260915","doi-asserted-by":"crossref","first-page":"496","DOI":"10.3928\/23258160-20141118-03","article-title":"Ultrahigh-speed swept-source OCT angiography in exudative AMD","volume":"45","author":"Moult","year":"2014","journal-title":"Ophthalmic Surg Lasers Imaging Retina"},{"key":"R4-20260915","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1038\/s41598-024-80562-4","article-title":"Scan speed affects quantitative optical coherence tomography angiography vascular metrics","volume":"14","author":"Vidal-Oliver","year":"2024","journal-title":"Sci Rep"},{"key":"R6-20260915","doi-asserted-by":"crossref","first-page":"973","DOI":"10.1080\/02713683.2023.2232957","article-title":"Impact of A-scan rate on image quality and acquisition time in OCT","volume":"48","author":"Bodenbender","year":"2023","journal-title":"Curr Eye Res"},{"key":"R7-20260915","doi-asserted-by":"crossref","first-page":"2637","DOI":"10.3390\/jcm12072637","article-title":"Quantitative and qualitative assessments of retinal structure with variable A-scan rate spectralis OCT: insights into IPL multilaminarity","volume":"12","author":"Lupidi","year":"2023","journal-title":"J Clin Med"},{"key":"R8-20260915","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1186\/s40942-025-00691-4","article-title":"Faricimab for treatment-resistant choroidal neovascularization (CNV) in neovascular age-related macular degeneration (nAMD): seven-months results using artificial intelligence and OCTA","volume":"11","author":"Heinke","year":"2025","journal-title":"Int J Retina Vitreous"},{"key":"R9-20260915","doi-asserted-by":"crossref","first-page":"108","DOI":"10.3928\/23258160-20230130-03","article-title":"Accuracy and time comparison between side-by-side and artificial intelligence overlayed images","volume":"54","author":"Cavichini","year":"2023","journal-title":"Ophthalmic Surg Lasers Imaging Retina"},{"key":"R10-20260915","doi-asserted-by":"crossref","first-page":"704823","DOI":"10.1155\/2014\/704823","article-title":"Retinal-image quality and night-vision performance after alcohol consumption","volume":"2014","author":"Castro","year":"2014","journal-title":"J Ophthalmol"},{"key":"R11-20260915","doi-asserted-by":"crossref","first-page":"100951","DOI":"10.1016\/j.preteyeres.2021.100951","article-title":"Retinal applications of swept source optical coherence tomography (OCT) and optical coherence tomography angiography (OCTA)","volume":"84","author":"La\u00edns","year":"2021","journal-title":"Prog Retin Eye Res"},{"key":"R12-20260915","doi-asserted-by":"crossref","first-page":"727","DOI":"10.1016\/j.ajo.2012.10.019","article-title":"Combined depth imaging technique on spectral-domain optical coherence tomography","volume":"155","author":"Barteselli","year":"2013","journal-title":"Am J Ophthalmol"},{"key":"R14-20260915","doi-asserted-by":"crossref","first-page":"1653","DOI":"10.1097\/IAE.0000000000003867","article-title":"The effect of increasing acquisition speed on optical coherence tomography angiography images: a qualitative and quantitative analysis","volume":"43","author":"Dolz-Marco","year":"2023","journal-title":"Retina"}],"container-title":["Retina"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1097\/IAE.0000000000004751","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,15]],"date-time":"2026-09-15T17:00:26Z","timestamp":1789491626000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1097\/IAE.0000000000004751"}},"subtitle":["A Paired-Eye Analysis"],"short-title":[],"issued":{"date-parts":[[2026,5]]},"references-count":12,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/iae.0000000000004751","relation":{},"ISSN":["0275-004X","1539-2864"],"issn-type":[{"value":"0275-004X","type":"print"},{"value":"1539-2864","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,5]]}}}