{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T16:21:00Z","timestamp":1786119660201,"version":"build-2736575974"},"reference-count":22,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"8","license":[{"start":{"date-parts":[[2026,8,1]],"date-time":"2026-08-01T00:00:00Z","timestamp":1785542400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,8]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>To evaluate comparative aspiration flow rates and core vitrectomy times of a reengineered 27-gauge (G) 20,000 cuts per minute (CPM) dual action cutting (two-dimensional cutting [TDC]) vitrectomy probe (TDC Veloce; DORC International B.V.) versus a standard 27-G 16,000 CPM TDC probe (DORC).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>In vitro investigations assessed comparative aspiration flow rates in Newtonian and non-Newtonian fluids using EVA Nexus system (DORC). In an accompanying single-surgeon randomized controlled clinical study, core vitrectomy duration in patients undergoing 27-G vitrectomy using either a TDC Veloce or regular TDC probe, both in combination with EVA Nexus (n = 42), was compared.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Significantly higher aspiration flow rates were achieved with the 27-G TDC Veloce probe compared with a 27-G TDC probe. The overall percentage increase in flow for TDC Veloce probe versus TDC probe was 31%, 69%, and 37% in water, artificial vitreous solution, and porcine vitreous, respectively (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001). Higher flow rates stabilized at cut speeds greater than 16,000 CPM. The mean (SD) core vitrectomy time (seconds) was 59.5 (6.1), 58.2 (3.3), and 98.6 (7.9) for the TDC Veloce 20,000 CPM, TDC Veloce 16,000 CPM, and TDC 16,000 CPM groups, respectively. The mean difference between the TDC Veloce 20,000 CPM and TDC 16,000 CPM groups was \u221239.1 seconds (95% CI: \u221244.57 to \u221233.63,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.0001).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Increased flow with the 27-G TDC Veloce probe resulted in a significantly shorter core vitrectomy time compared with a standard 27-G TDC probe, suggesting greater procedural efficiency during vitrectomy with the modified vitrectome.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/iae.0000000000004870","type":"journal-article","created":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T15:00:28Z","timestamp":1777388428000},"page":"1457-1464","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["COMPARATIVE FLOW AND OPERATING EFFICIENCY OF TWO-DIMENSIONAL CUTTING VELOCE 27-GAUGE VITRECTOME"],"prefix":"10.1097","volume":"46","author":[{"given":"Mitrofanis","family":"Pavlidis","sequence":"first","affiliation":[{"name":"Augencentrum K\u00f6ln, Cologne, Germany;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David H.","family":"Steel","sequence":"additional","affiliation":[{"name":"Sunderland Eye Infirmary, Sunderland, United Kingdom;"},{"name":"Biosciences Institute, Newcastle University, Newcastle Upon Tyne, United Kingdom; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hideyasu","family":"Oh","sequence":"additional","affiliation":[{"name":"Hyogo Prefectural Amagasaki General Medical Center, Hyogo, Japan."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20260717","doi-asserted-by":"crossref","first-page":"6428","DOI":"10.3390\/jcm11216428","article-title":"Advances in vitreoretinal surgery","volume":"11","author":"Ribeiro","year":"2022","journal-title":"J Clin Med"},{"key":"R2-20260717","doi-asserted-by":"crossref","first-page":"667","DOI":"10.1080\/17434440.2025.2507969","article-title":"Advances in high-speed vitrectomy\u2013surpassing the speed barrier in retinal surgery: a concise review","volume":"22","author":"Menia","year":"2025","journal-title":"Expert Rev Med Devices"},{"key":"R3-20260717","doi-asserted-by":"crossref","first-page":"3849316","DOI":"10.1155\/2016\/3849316","article-title":"Two-dimensional cutting (TDC) vitrectome: in vitro flow assessment and prospective clinical study evaluating core vitrectomy efficiency versus standard vitrectome","volume":"2016","author":"Pavlidis","year":"2016","journal-title":"J Ophthalmol"},{"key":"R4-20260717","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1167\/tvst.7.6.19","article-title":"Fluidics of single and double blade guillotine vitrectomy probes in balanced salt solution and artificial vitreous","volume":"7","author":"Romano","year":"2018","journal-title":"Transl Vis Sci Technol"},{"key":"R5-20260717","doi-asserted-by":"crossref","first-page":"2150","DOI":"10.1097\/IAE.0000000000003573","article-title":"Fluidic performance of a dual action vitrectomy probe compared with a single-action probe","volume":"42","author":"Steel","year":"2022","journal-title":"Retina"},{"key":"R6-20260717","doi-asserted-by":"crossref","first-page":"8","DOI":"10.1186\/s40942-020-00277-2","article-title":"Comparison of modern high-speed vitrectomy systems and the advantages of using dual-bladed probes","volume":"7","author":"Oravecz","year":"2021","journal-title":"Int J Retina Vitreous"},{"key":"R7-20260717","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1186\/s40942-024-00613-w","article-title":"Performance, safety and efficiency comparison between a 25G 20,000 and a 10,000 cuts per minute vitrectomy: a prospective randomized control study","volume":"11","author":"Chow","year":"2025","journal-title":"Int J Retina Vitreous"},{"key":"R8-20260717","doi-asserted-by":"crossref","first-page":"2309","DOI":"10.1097\/IAE.0000000000001882","article-title":"In vitro flow analysis of novel double-cutting, open-port, ultrahigh-speed vitrectomy systems","volume":"38","author":"Zehetner","year":"2018","journal-title":"Retina"},{"key":"R9-20260717","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1186\/s40942-024-00563-3","article-title":"Clinical trial to test the safety of the EVA nexus surgical platform","volume":"10","author":"Stalmans","year":"2024","journal-title":"Int J Retina Vitreous"},{"key":"R10-20260717","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1167\/tvst.14.8.26","article-title":"The influence of fluids with varying rheological properties on the field of fluidic effect during vitrectomy","volume":"14","author":"Vedeniapina","year":"2025","journal-title":"Transl Vis Sci Technol"},{"key":"R11-20260717","doi-asserted-by":"crossref","first-page":"1113","DOI":"10.1007\/s00417-020-05061-4","article-title":"Experimental assessment of the performance of vitreous cutters with fluids with different rheological properties","volume":"259","author":"Nepita","year":"2021","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"R12-20260717","doi-asserted-by":"crossref","first-page":"1896","DOI":"10.1097\/IAE.0000000000000143","article-title":"Introducing new vitreous cutter blade shapes: a fluid dynamics study","volume":"34","author":"Rossi","year":"2014","journal-title":"Retina"},{"key":"R13-20260717","doi-asserted-by":"crossref","first-page":"8289","DOI":"10.1167\/iovs.14-15467","article-title":"Instantaneous flow rate of vitreous cutter probes","volume":"55","author":"Rossi","year":"2014","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R14-20260717","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1167\/tvst.5.4.1","article-title":"Hydraulic resistance of vitreous cutters: the impact of blade design and cut rate","volume":"5","author":"Rossi","year":"2016","journal-title":"Transl Vis Sci Technol"},{"key":"R15-20260717","doi-asserted-by":"crossref","first-page":"216","DOI":"10.1159\/000521468","article-title":"Comparisons of flow dynamics of dual-blade to single-blade beveled-tip vitreous cutters","volume":"65","author":"Inoue","year":"2022","journal-title":"Ophthalmic Res"},{"key":"R16-20260717","first-page":"1234","article-title":"Fluidic performance of a dual-action vitrectomy probe compared with a single-action probe","volume":"42","author":"Beischel","year":"2022","journal-title":"Retina"},{"key":"R17-20260717","doi-asserted-by":"crossref","first-page":"928","DOI":"10.1097\/IAE.0b013e31826f069e","article-title":"Performance analysis of ultrahigh-speed vitreous cutter system","volume":"33","author":"Ribeiro","year":"2013","journal-title":"Retina"},{"key":"R18-20260717","doi-asserted-by":"crossref","first-page":"933","DOI":"10.1097\/IAE.0b013e3182733f38","article-title":"Analysis of a 23-gauge ultra high-speed cutter with duty cycle control","volume":"33","author":"Diniz","year":"2013","journal-title":"Retina"},{"key":"R19-20260717","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1167\/tvst.9.8.46","article-title":"Simulation of vitreous traction force and flow rate of high speed dual-pneumatic 7500 cuts per minute vitrectomy probes","volume":"9","author":"Missel","year":"2020","journal-title":"Transl Vis Sci Technol"},{"key":"R20-20260717","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1167\/tvst.11.3.29","article-title":"Human vitreous collagen fragments dimension as a function of vitrectomy cut rate","volume":"11","author":"Rossi","year":"2022","journal-title":"Transl Vis Sci Technol"},{"key":"R21-20260717","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1016\/j.ajo.2016.01.012","article-title":"Outcomes of 27 gauge microincision vitrectomy surgery for posterior segment disease","volume":"164","author":"Masri","year":"2016","journal-title":"Am J Ophthalmol"},{"key":"R22-20260717","doi-asserted-by":"crossref","first-page":"991","DOI":"10.1097\/IAE.0000000000004048","article-title":"25-gauge versus 27-gauge vitrectomy for management of vitreoretinal diseases: a large prospective randomized trial","volume":"44","author":"Benzerroug","year":"2024","journal-title":"Retina"}],"container-title":["Retina"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1097\/IAE.0000000000004870","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,6]],"date-time":"2026-08-06T18:41:30Z","timestamp":1786041690000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1097\/IAE.0000000000004870"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8]]},"references-count":22,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/iae.0000000000004870","relation":{},"ISSN":["0275-004X","1539-2864"],"issn-type":[{"value":"0275-004X","type":"print"},{"value":"1539-2864","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8]]}}}