{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,20]],"date-time":"2026-10-20T21:38:53Z","timestamp":1792532333015,"version":"4.5.0"},"reference-count":17,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"11","license":[{"start":{"date-parts":[[2026,11,1]],"date-time":"2026-11-01T00:00:00Z","timestamp":1793491200000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"funder":[{"DOI":"10.13039\/spiyfsntwd9t","name":"Acusurgical","doi-asserted-by":"publisher","award":["N\/A"],"award-info":[{"award-number":["N\/A"]}],"id":[{"id":"10.13039\/spiyfsntwd9t","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,11]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>To evaluate the initial safety and feasibility of the Luca system, a telemanipulated robotic system with bimanual capabilities, used to perform a core vitrectomy during surgical treatment of epiretinal membrane or macular hole.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>This was a prospective, single-arm, first-in-human study conducted at Ghent University Hospital in Belgium. Seven patients (mean age 71.0 \u00b1 11.5 years) scheduled for vitreoretinal surgery for epiretinal membrane (n = 6) or macular hole (n = 1) were enrolled between February and June 2024. The Luca system was used to create a posterior vitreous detachment and to perform a core vitrectomy, after which the remainder of the surgery (e.g., membrane peeling) was completed manually. The primary safety end point was the incidence and severity of device-related adverse event (AEs). Secondary end points included the proportion of subjects with iatrogenic retinal tears and changes in best-corrected distance visual acuity and best-corrected near visual acuity.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>All surgeries were completed without serious safety incidents, and no device-related AEs or serious AEs were reported. No accidental retinal touches, hemorrhages, or iatrogenic retinal tears related to the robotic system occurred. In six of seven patients (85.7%), the robotic-assisted part of the procedure was successfully completed according to preoperative planning. At 3 months, five of seven patients (71.4%) had a best-corrected distance visual acuity gain.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>The initial clinical experience with the Luca robotic system demonstrates a favorable safety, feasibility, and performance profile for vitreoretinal surgery in patients with acquired maculopathies. The safety profile seems comparable with that of manual surgery.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/iae.0000000000004958","type":"journal-article","created":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T21:00:40Z","timestamp":1786136440000},"page":"1988-1995","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["TELEMANIPULATED ROBOT-ASSISTED VITREORETINAL SURGERY"],"prefix":"10.1097","volume":"46","author":[{"given":"Fanny","family":"Nerinckx","sequence":"first","affiliation":[{"name":"Department of Ophthalmology, Ghent University Hospital, Ghent, Belgium;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maxim","family":"Van Slycken","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Ghent University Hospital, Ghent, Belgium;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Julie","family":"Van Puyvelde","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Ghent University Hospital, Ghent, Belgium;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bart","family":"Leroy","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Ghent University Hospital, Ghent, Belgium;"},{"name":"Center for Medical Genetics, Ghent University Hospital, Ghent, Belgium; and"},{"name":"Department of Head & Skin, Ghent University, Ghent, Belgium."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20261020","doi-asserted-by":"crossref","first-page":"893","DOI":"10.1109\/JPROC.2022.3169466","article-title":"Robotic assistance for intraocular microsurgery: challenges and perspectives","volume":"110","author":"Iordachita","year":"2022","journal-title":"Proc IEEE Inst Electr Electron Eng"},{"key":"R2-20261020","first-page":"1","article-title":"Robot-assisted vitreoretinal surgery: current perspectives","volume":"5","author":"Roizenblatt","year":"2018","journal-title":"Robot Surg"},{"key":"R4-20261020","doi-asserted-by":"crossref","first-page":"2114","DOI":"10.1007\/s12325-021-01692-z","article-title":"A review of robotic and OCT-aided systems for vitreoretinal surgery","volume":"38","author":"Ahronovich","year":"2021","journal-title":"Adv Ther"},{"key":"R5-20261020","doi-asserted-by":"crossref","first-page":"1554","DOI":"10.1038\/s41433-020-0837-9","article-title":"Advanced robotic surgical systems in ophthalmology","volume":"34","author":"Gerber","year":"2020","journal-title":"Eye (Lond)"},{"key":"R6-20261020","doi-asserted-by":"crossref","first-page":"312","DOI":"10.3109\/10929080109146301","article-title":"State of the art in surgical robotics: clinical applications and technology challenges","volume":"6","author":"Cleary","year":"2001","journal-title":"Comput Aided Surg"},{"key":"R7-20261020","doi-asserted-by":"crossref","first-page":"672","DOI":"10.1111\/aos.14003","article-title":"Human\/robotic interaction: vision limits performance in simulated vitreoretinal surgery","volume":"97","author":"de Smet","year":"2019","journal-title":"Acta Ophthalmol"},{"key":"R8-20261020","doi-asserted-by":"crossref","first-page":"1040","DOI":"10.1038\/s41433-022-02125-z","article-title":"Robotic assisted orbital surgery (RAOS)-A novel approach to orbital oncology surgery","volume":"37","author":"Jeannon","year":"2023","journal-title":"Eye (Lond)"},{"key":"R9-20261020","doi-asserted-by":"crossref","first-page":"1329","DOI":"10.1097\/ICO.0000000000000561","article-title":"Robotically assisted pterygium surgery: first human case","volume":"34","author":"Bourcier","year":"2015","journal-title":"Cornea"},{"key":"R10-20261020","doi-asserted-by":"crossref","first-page":"248","DOI":"10.1097\/ICU.0000000000000476","article-title":"Robotic-assisted surgery in ophthalmology","volume":"29","author":"de Smet","year":"2018","journal-title":"Curr Opin Ophthalmol"},{"key":"R11-20261020","doi-asserted-by":"crossref","first-page":"405","DOI":"10.18502\/jovr.v18i4.14552","article-title":"High-speed beveled tip versus standard tip vitrectomy probe: a prospective randomized clinical trial","volume":"18","author":"Patel","year":"2023","journal-title":"J Ophthalmic Vis Res"},{"key":"R12-20261020","doi-asserted-by":"crossref","first-page":"249","DOI":"10.3341\/kjo.2009.23.4.249","article-title":"The clinical course of the idiopathic epiretinal membrane after surgery","volume":"23","author":"Kwon","year":"2009","journal-title":"Korean J Ophthalmol"},{"key":"R13-20261020","doi-asserted-by":"crossref","first-page":"1057","DOI":"10.1111\/ceo.14174","article-title":"Randomised controlled trial on robot-assisted versus manual surgery for pucker peeling","volume":"50","author":"Faridpooya","year":"2022","journal-title":"Clin Exp Ophthalmol"},{"key":"R14-20261020","doi-asserted-by":"crossref","first-page":"649","DOI":"10.1038\/s41551-018-0248-4","article-title":"First-in-human study of the safety and viability of intraocular robotic surgery","volume":"2","author":"Edwards","year":"2018","journal-title":"Nat Biomed Eng"},{"key":"R15-20261020","doi-asserted-by":"crossref","first-page":"244","DOI":"10.1016\/j.oret.2018.10.016","article-title":"Comparison of a three-dimensional Heads-Up display surgical platform with a standard operating microscope for macular surgery","volume":"3","author":"Talcott","year":"2019","journal-title":"Ophthalmol Retina"},{"key":"R16-20261020","doi-asserted-by":"crossref","first-page":"2768","DOI":"10.3390\/jcm12082768","article-title":"Robot-assisted epiretinal membrane peeling: a prospective assessment of Pre- and intra-operative times and of surgeons' subjective perceptions","volume":"12","author":"Turgut","year":"2023","journal-title":"J Clin Med"},{"key":"R17-20261020","first-page":"212","article-title":"Toward the art of robotic-assisted vitreoretinal surgery","volume":"12","author":"Molaei","year":"2017","journal-title":"J Ophthalmic Vis Res"},{"key":"R18-20261020","doi-asserted-by":"crossref","first-page":"100085","DOI":"10.1016\/j.xops.2021.100085","article-title":"Clinical evaluation of an instrument-integrated OCT-based distance sensor for robotic vitreoretinal surgery","volume":"1","author":"Cereda","year":"2021","journal-title":"Ophthalmol Sci"}],"container-title":["Retina"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1097\/IAE.0000000000004958","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,20]],"date-time":"2026-10-20T21:00:17Z","timestamp":1792530017000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1097\/IAE.0000000000004958"}},"subtitle":["Safety and Effectiveness of the Luca System in Robotically Performed Core Vitrectomy in ERM or Macular Hole Surgical Treatment"],"short-title":[],"issued":{"date-parts":[[2026,11]]},"references-count":17,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/iae.0000000000004958","relation":{},"ISSN":["0275-004X","1539-2864"],"issn-type":[{"value":"0275-004X","type":"print"},{"value":"1539-2864","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,11]]}}}