{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,13]],"date-time":"2026-02-13T10:56:21Z","timestamp":1770980181128,"version":"3.50.1"},"reference-count":33,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2015,1]]},"DOI":"10.1097\/icl.0000000000000060","type":"journal-article","created":{"date-parts":[[2014,9,17]],"date-time":"2014-09-17T13:24:23Z","timestamp":1410960263000},"page":"19-24","source":"Crossref","is-referenced-by-count":32,"title":["Visual Performance of Four Simultaneous-Image Multifocal Contact Lenses Under Dim and Glare Conditions"],"prefix":"10.1097","volume":"41","author":[{"given":"Santiago","family":"Garc\u00eda-L\u00e1zaro","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Teresa","family":"Ferrer-Blasco","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David","family":"Madrid-Costa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"C\u00e9sar","family":"Albarr\u00e1n-Diego","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Robert","family":"Mont\u00e9s-Mic\u00f3","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-4-20210128","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1111\/j.1444-0938.2010.00524.x","article-title":". An international survey of contact lens prescribing for presbyopia.","volume":"94","author":"Morgan","year":"2011","journal-title":"Clin Exp Optom"},{"key":"R2-4-20210128","first-page":"13","article-title":"Better designs improve success with soft toric multifocals.","volume":"22","author":"Jackson","year":"2007","journal-title":"Contact Lens Spectr"},{"key":"R3-4-20210128","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1016\/j.clae.2006.02.008","article-title":"A decade of contact lens prescribing trends in the United Kingdom (1996-2005).","volume":"29","author":"Morgan","year":"2006","journal-title":"Cont Lens Anterior Eye"},{"key":"R4-4-20210128","doi-asserted-by":"crossref","first-page":"181","DOI":"10.1097\/01.ICL.0000072827.42925.49","article-title":". Successful monovision contact lens wearers refitted with bifocal contact lenses.","volume":"29","author":"Situ","year":"2003","journal-title":"Eye Contact Lens"},{"key":"R5-4-20210128","first-page":"221","article-title":"Early symptomatic presbyopeswhat correction modality works best Eye Contact L","volume":"35","author":"Woods","year":"2009","journal-title":"ens"},{"key":"R6-4-20210128","first-page":"201","article-title":"Multifocal contact lenseslook again!","volume":"32","author":"Hutnik","year":"1997","journal-title":"Can J Ophthalmol"},{"key":"R7-4-20210128","first-page":"743","article-title":"Physiology of aging and its influence on the contact lens prescription.","volume":"62","author":"Benjamin","year":"1991","journal-title":"J Am Optom Assoc"},{"key":"R8-4-20210128","first-page":"482","article-title":"Does the presbyopic visual system adapt to contact lenses Optom Vis S","volume":"70","author":"Sheedy","year":"1993","journal-title":"ci"},{"key":"R10-4-20210128","first-page":"468","article-title":"A critical review of presbyopic add determination.","volume":"58","author":"Hanlon","year":"1987","journal-title":"J Am Optom Assoc"},{"key":"R11-4-20210128","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1097\/00006324-197902000-00002","article-title":"A comparison of three methods for determining the reading addition.","volume":"56","author":"Woo","year":"1979","journal-title":"Am J Optom Physiol Opt"},{"key":"R12-4-20210128","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1111\/opo.12008","article-title":". Visual performance of two simultaneous vision multifocal contact lenses.","volume":"33","author":"Madrid-Costa","year":"2013","journal-title":"Ophthalmic Physiol Opt"},{"key":"R13-4-20210128","first-page":"334","article-title":"Fluctuation in visual acuity during soft toric contact lens wear.","volume":"8","author":"Chamberlain","year":"2011","journal-title":"Optom Vis Sci"},{"key":"R14-4-20210128","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1111\/j.1444-0938.2002.tb03033.x","article-title":"Comparative clinical performance of two silicone hydrogel contact lenses for continuous wear.","volume":"83","author":"Morgan","year":"2002","journal-title":"Clin Exp Optom"},{"key":"R15-4-20210128","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1136\/bjo.88.1.11","article-title":". The usefulness of Vistech and FACT contrast sensitivity charts for cataract and refractive surgery outcomes research.","volume":"88","author":"Pesudovs","year":"2004","journal-title":"Br J Ophthalmol"},{"key":"R16-4-20210128","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1111\/j.1444-0938.2011.00666.x","article-title":". Visual performance with simultaneous vision multifocal contact lenses.","volume":"95","author":"Llorente-Guillemot","year":"2012","journal-title":"Clin Exp Optom"},{"key":"R17-4-20210128","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1111\/j.1444-0938.2012.00791.x","article-title":". Visual performance comparison between contact lens-based pinhole and simultaneous vision contact lenses.","volume":"96","author":"Garcia-Lazaro","year":"2013","journal-title":"Clin Exp Optom"},{"key":"R18-4-20210128","doi-asserted-by":"crossref","first-page":"266","DOI":"10.1097\/01.opx.0000216098.62165.34","article-title":"Comparison of multifocal and monovision soft contact lens corrections in subjects with low-astigmatic presbyopia.","volume":"83","author":"Richdale","year":"2006","journal-title":"Optom Vis Sci"},{"key":"R19-4-20210128","doi-asserted-by":"crossref","first-page":"476","DOI":"10.1097\/00006324-199306000-00005","article-title":". Effects of target distance and pupil size on letter contrast sensitivity with simultaneous vision bifocal contact lenses.","volume":"70","author":"Bradley","year":"1993","journal-title":"Optom Vis Sci"},{"key":"R20-4-20210128","doi-asserted-by":"crossref","first-page":"733","DOI":"10.1097\/00006324-199612000-00003","article-title":". Infrared pupillometry in presbyopes fitted with soft contact lenses.","volume":"73","author":"Chateau","year":"1996","journal-title":"Optom Vis Sci"},{"key":"R21-4-20210128","doi-asserted-by":"crossref","first-page":"702","DOI":"10.1097\/00006324-198510000-00006","article-title":"Performance characteristics of a hydrophilic concentric bifocal contact lens.","volume":"62","author":"Erickson","year":"1985","journal-title":"Am J Optom Physiol Opt"},{"key":"R22-4-20210128","first-page":"198","article-title":". Optical design considerations for contact lens bifocals.","volume":"59","author":"Erickson","year":"1988","journal-title":"J Am Optom Assoc"},{"key":"R23-4-20210128","doi-asserted-by":"crossref","first-page":"417","DOI":"10.1097\/00006324-198805000-00019","article-title":"Pupil dependency of bifocal contact lenses.","volume":"65","author":"Borish","year":"1988","journal-title":"Am J Optom Physiol Opt"},{"key":"R24-4-20210128","doi-asserted-by":"crossref","first-page":"611","DOI":"10.1097\/01.opx.0000232185.00091.45","article-title":"Visual performance of subjects wearing presbyopic contact lenses.","volume":"83","author":"Rajagopalan","year":"2006","journal-title":"Optom Vis Sci"},{"key":"R25-4-20210128","doi-asserted-by":"crossref","first-page":"1520","DOI":"10.1038\/1821520a0","article-title":"Dependence on age of the diameter of the pupil in the dark.","volume":"182","author":"Kadlecova","year":"1958","journal-title":"Nature"},{"key":"R26-4-20210128","first-page":"401","article-title":"Contrast sensitivity in the presence of glare light.","volume":"19","author":"Paulson","year":"1980","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R27-4-20210128","doi-asserted-by":"crossref","first-page":"327","DOI":"10.1007\/BF00142360","article-title":"Importance of pathological light scatter for visual disability.","volume":"61","author":"Van den Berg","year":"1986","journal-title":"Doc Ophthalmol"},{"key":"R28-4-20210128","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1097\/00061198-200304000-00009","article-title":". Quality of life in glaucoma and its relationship with visual function.","volume":"12","author":"Nelson","year":"2003","journal-title":"J Glaucoma"},{"key":"R29-4-20210128","doi-asserted-by":"crossref","first-page":"941","DOI":"10.1016\/S0886-3350(02)01846-1","article-title":". Impact of cataract surgery on self-reported visual difficulties: Comparison with a no-surgery reference group.","volume":"29","author":"McGwin","year":"2003","journal-title":"J Cataract Refract Surg"},{"key":"R30-4-20210128","doi-asserted-by":"crossref","first-page":"774","DOI":"10.1001\/archopht.120.6.774","article-title":". How does visual impairment affect performance on tasks of everyday life the SEE project.","volume":"120","author":"West","year":"2002","journal-title":"Arch Ophthalmol"},{"key":"R31-4-20210128","first-page":"207","article-title":". The SKILL Card. An acuity test of reduced luminance and contrast.","volume":"38","author":"Haegerstrom-Portnoy","year":"1999","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R32-4-20210128","doi-asserted-by":"crossref","first-page":"305","DOI":"10.1007\/BF00915735","article-title":"Good subjective presbyopic correction with newly designed aspheric multifocal contact lens.","volume":"17","author":"Zandvoort","year":"1993","journal-title":"Int Ophthalmol"},{"key":"R33-4-20210128","doi-asserted-by":"crossref","first-page":"1325","DOI":"10.1080\/09500340600855452","article-title":"Contrast sensitivity with presbyopic contact lenses.","volume":"54","author":"Rajagopalan","year":"2007","journal-title":"J Mod Opt"},{"key":"R34-4-20210128","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1097\/ICL.0b013e3181a20361","article-title":". Utility of short-term evaluation of presbyopic contact lens performance.","volume":"35","author":"Papas","year":"2009","journal-title":"Eye Contact Lens"}],"container-title":["Eye &amp; Contact Lens: Science &amp; Clinical Practice"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/ICL.0000000000000060","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,5,14]],"date-time":"2021-05-14T00:59:39Z","timestamp":1620953979000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00140068-201501000-00004"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,1]]},"references-count":33,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2015]]}},"URL":"https:\/\/doi.org\/10.1097\/icl.0000000000000060","relation":{},"ISSN":["1542-2321"],"issn-type":[{"value":"1542-2321","type":"print"}],"subject":[],"published":{"date-parts":[[2015,1]]}}}