{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,25]],"date-time":"2026-09-25T15:15:06Z","timestamp":1790349306078,"version":"4.1.0"},"reference-count":34,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"9","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2023,9]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>To investigate the effect of front surface eccentricity (FSE) of scleral lenses (SLs) on corrected distance visual acuity (CDVA), contrast sensitivity (CS), and higher-order aberrations (HOAs) in keratoconic eyes.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>Fifteen keratoconic eyes fitted with BostonSight SCLERAL lenses of different eccentricity values (FSE0=0, FSE1=0.30, and FSE2=0.60). CDVA, CS, and HOAs were measured at baseline and after 30 min of SL wear. CDVA and CS were measured with the Early Treatment Diabetic Retinopathy Study and Pelli\u2013Robson chart, respectively, and iTrace aberrometer was used to evaluate the HOAs.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>Baseline CDVA was 0.30\u00b10.29, which significantly improved to 0.10\u00b10.11, 0.05\u00b10.06, and 0.05\u00b10.08 logMAR with FSE0, FSE1, and FSE2, respectively (<jats:italic toggle=\"yes\">P<\/jats:italic>&lt;0.05). The post hoc showed no significant difference between eccentricities. Baseline CS was 1.19\u00b10.47, which improved to 1.54\u00b10.12, 1.59\u00b10.10, and 1.60\u00b10.11 with FSE0, FSE1, and FSE2, respectively (<jats:italic toggle=\"yes\">P<\/jats:italic>&lt;0.01), but post hoc showed no significant difference between eccentricities. A statistically significant reduction was found in HOAs when compared with baseline (<jats:italic toggle=\"yes\">P<\/jats:italic>&lt;0.01). Comparison between eccentricities showed a significant difference only between FSE0 and FSE1 for RMS coma (<jats:italic toggle=\"yes\">P<\/jats:italic>=0.01) and RMS spherical aberrations (<jats:italic toggle=\"yes\">P<\/jats:italic>=0.004) where FSE1 showed better performance in reducing HOAs compared with FSE0. HO-RMS, RMS secondary astigmatism, and RMS trefoil showed no significant difference between eccentricities, but FSE1 and FSE2 performed superior to FSE0.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion:<\/jats:title>\n            <jats:p>BostonSight SCLERAL lenses with varying eccentricities corrected a significant amount of HOAs and improved CDVA and CS in keratoconus patients. Practitioners should be aware of this distinct feature of SLs and use it as needed to improve visual performance.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/icl.0000000000001007","type":"journal-article","created":{"date-parts":[[2023,6,5]],"date-time":"2023-06-05T13:01:23Z","timestamp":1685970083000},"page":"374-378","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":11,"title":["Impact of Scleral Lens Front Surface Eccentricity on Visual Acuity, Contrast Sensitivity, and Higher-Order Aberrations in Eyes With Keratoconus"],"prefix":"10.1097","volume":"49","author":[{"given":"Aparna","family":"Badrinarayanan","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Akshaya C.","family":"Balakrishnan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ronit","family":"Dutta","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"R. Mahesh","family":"Kumar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Asif","family":"Iqbal","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2023,6,2]]},"reference":[{"key":"R1-20250528","doi-asserted-by":"crossref","first-page":"1540","DOI":"10.1097\/ICO.0b013e3182a73802","article-title":"Functional and visual improvement with prosthetic replacement of the ocular surface ecosystem scleral lenses for irregular corneas","volume":"32","author":"Lee","year":"2013","journal-title":"Cornea"},{"key":"R2-20250528","doi-asserted-by":"crossref","first-page":"e27","DOI":"10.1016\/j.clae.2019.10.091","article-title":"Prosthetic replacement of the ocular surface ecosystem for corneal irregularity: Visual improvement and optical device characteristics","volume":"42","author":"Kumar","year":"2019","journal-title":"Contact Lens Anterior Eye"},{"key":"R3-20250528","doi-asserted-by":"crossref","first-page":"664","DOI":"10.1111\/opo.12802","article-title":"The effect of scleral lenses on vision, refraction and aberrations in post-LASIK ectasia, keratoconus and pellucid marginal degeneration","volume":"41","author":"Kumar","year":"2021","journal-title":"Ophthalmic Physiol Opt"},{"key":"R4-20250528","doi-asserted-by":"crossref","first-page":"420","DOI":"10.1016\/j.clae.2016.06.010","article-title":"Clinical outcomes of scleral Misa lenses for visual rehabilitation in patients with pellucid marginal degeneration","volume":"39","author":"Asena","year":"2016","journal-title":"Contact Lens Anterior Eye"},{"key":"R5-20250528","doi-asserted-by":"crossref","first-page":"670","DOI":"10.1016\/j.clae.2019.06.002","article-title":"Effects of a semi-scleral contact lens on refraction and higher order aberrations","volume":"42","author":"Kumar","year":"2019","journal-title":"Contact Lens Anterior Eye"},{"key":"R6-20250528","doi-asserted-by":"crossref","first-page":"475","DOI":"10.5935\/0004-2749.20180089","article-title":"Visual performance of scleral lenses and their impact on quality of life in patients with irregular corneas","volume":"81","author":"Ozek","year":"2018","journal-title":"Arquivos Brasileiros de Oftalmologia"},{"key":"R7-20250528","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1097\/ICL.0000000000000340","article-title":"Irregular corneas: Improve visual function with scleral contact lenses","volume":"44","author":"de Luis Eguileor","year":"2018","journal-title":"Eye Contact Lens: Sci Clin Pract"},{"key":"R8-20250528","doi-asserted-by":"crossref","first-page":"162","DOI":"10.1016\/j.clae.2017.07.002","article-title":"The temporal dynamics of miniscleral contact lenses: Central corneal clearance and centration","volume":"41","author":"Vincent","year":"2018","journal-title":"Contact Lens Anterior Eye"},{"key":"R9-20250528","doi-asserted-by":"crossref","first-page":"761","DOI":"10.1097\/OPX.0000000000001576","article-title":"Clinical outcomes of scleral lens fitting with a data-driven, quadrant-specific design: Multicenter review","volume":"97","author":"Barnett","year":"2020","journal-title":"Optom Vis Sci"},{"key":"R10-20250528","doi-asserted-by":"crossref","first-page":"2013","DOI":"10.1016\/j.ophtha.2007.01.008","article-title":"Characterizing the wave aberration in eyes with keratoconus or penetrating keratoplasty using a high\u2013dynamic range wave front sensor","volume":"114","author":"Pantanelli","year":"2007","journal-title":"Ophthalmology"},{"key":"R11-20250528","doi-asserted-by":"crossref","first-page":"620","DOI":"10.1364\/JOSAA.19.000620","article-title":"Calculated impact of higher-order monochromatic aberrations on retinal image quality in a population of human eyes: Erratum","volume":"19","author":"Guirao","year":"2002","journal-title":"J Opt Soc Am A"},{"key":"R12-20250528","doi-asserted-by":"crossref","first-page":"1328","DOI":"10.1016\/S0161-6420(00)00159-7","article-title":"Changes in anterior and posterior corneal curvatures in keratoconus","volume":"107","author":"Tomidokoro","year":"2000","journal-title":"Ophthalmology"},{"key":"R13-20250528","doi-asserted-by":"crossref","first-page":"5645","DOI":"10.1167\/iovs.08-1874","article-title":"Posterior corneal aberrations and their compensation effects on anterior corneal aberrations in keratoconic eyes","volume":"49","author":"Chen","year":"2008","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R14-20250528","doi-asserted-by":"crossref","first-page":"238","DOI":"10.1097\/OPX.0000000000001365","article-title":"Comparison of wavefront-guided and best conventional scleral lenses after habituation in eyes with corneal ectasia","volume":"96","author":"Hastings","year":"2019","journal-title":"Optom Vis Sci"},{"key":"R15-20250528","doi-asserted-by":"crossref","first-page":"108","DOI":"10.1016\/j.optom.2013.04.001","article-title":"Visual performance with changes in eccentricity in PROSE device: A case report","volume":"7","author":"Jagadeesh","year":"2014","journal-title":"J Optom"},{"key":"R16-20250528","doi-asserted-by":"crossref","first-page":"682","DOI":"10.1016\/j.ajo.2010.10.027","article-title":"The impact of the Boston ocular surface prosthesis on wavefront higher-order aberrations","volume":"151","author":"Gumus","year":"2011","journal-title":"Am J Ophthalmol"},{"key":"R17-20250528","first-page":"6349","article-title":"The effect of scleral lens eccentricity on vision in patients for corneal ectasia","volume":"50","author":"Hussoin","year":"2009","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R18-20250528","doi-asserted-by":"crossref","first-page":"300","DOI":"10.1097\/ICL.0b013e3182657da5","article-title":"The effect of optic asphericity on visual rehabilitation of corneal ectasia with a prosthetic device","volume":"38","author":"Hussoin","year":"2012","journal-title":"Eye Contact Lens: Sci Clin Pract"},{"key":"R19-20250528","doi-asserted-by":"crossref","first-page":"223","DOI":"10.1016\/j.clae.2007.03.001","article-title":"Collaborative longitudinal evaluation of keratoconus (CLEK) study: Methods and findings to date","volume":"30","author":"Wagner","year":"2007","journal-title":"Contact Lens Anterior Eye"},{"key":"R20-20250528","doi-asserted-by":"crossref","first-page":"178","DOI":"10.1111\/opo.12908","article-title":"Fluid reservoir thickness and aberration relationship in keratoconic eyes with scleral lenses","volume":"42","author":"Balakrishnan","year":"2022","journal-title":"Ophthalmic Physiol Opt"},{"key":"R22-20250528","doi-asserted-by":"crossref","first-page":"S951","DOI":"10.3928\/1081597X-20090915-10","article-title":"Total, corneal, and internal ocular optical aberrations in patients with keratoconus","volume":"25","author":"Schlegel","year":"2009","journal-title":"J Refractive Surg"},{"key":"R23-20250528","first-page":"423","article-title":"Derivation of corneal flattening factor, p\u2010value","volume":"14","author":"Lam","year":"1994","journal-title":"Ophthalmic Physiol Opt"},{"key":"R24-20250528","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1046\/j.1475-1313.2003.00100.x","article-title":"The asphericity, curvature and tilt of the human cornea measured using a videokeratoscope","volume":"23","author":"Douthwaite","year":"2003","journal-title":"Ophthalmic Physiol Opt"},{"key":"R25-20250528","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1111\/j.1475-1313.1993.tb00428.x","article-title":"Mathematical models of the general corneal surface","volume":"13","author":"Burek","year":"1993","journal-title":"Ophthalmic Physiol Opt"},{"key":"R26-20250528","doi-asserted-by":"crossref","first-page":"209","DOI":"10.1016\/S0886-3350(97)80344-6","article-title":"Corneal topography using the Holladay diagnostic summary","volume":"23","author":"Holladay","year":"1997","journal-title":"J Cataract Refractive Surg"},{"key":"R27-20250528","doi-asserted-by":"crossref","first-page":"377","DOI":"10.1111\/j.1475-1313.1993.tb00494.x","article-title":"Measurement of corneal topography in keratoconus","volume":"13","author":"Cunha","year":"1993","journal-title":"Ophthalmic Physiol Opt"},{"key":"R28-20250528","doi-asserted-by":"crossref","first-page":"1488","DOI":"10.1038\/sj.eye.6702902","article-title":"Higher-order wavefront aberration and letter-contrast sensitivity in keratoconus","volume":"22","author":"Okamoto","year":"2008","journal-title":"Eye"},{"key":"R29-20250528","doi-asserted-by":"crossref","first-page":"653","DOI":"10.1136\/bjo.2003.027029","article-title":"Contrast and glare testing in keratoconus and after penetrating keratoplasty","volume":"88","author":"Pesudovs","year":"2004","journal-title":"Br J Ophthalmol"},{"key":"R30-20250528","doi-asserted-by":"crossref","first-page":"6850","DOI":"10.1167\/iovs.10-5188","article-title":"Peripheral ocular aberrations in mild and moderate keratoconus","volume":"51","author":"Atchison","year":"2010","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R31-20250528","doi-asserted-by":"crossref","first-page":"1996","DOI":"10.1016\/S0161-6420(02)01279-4","article-title":"Wavefront aberrations measured with Hartmann-Shack sensor in patients with keratoconus","volume":"109","author":"Maeda","year":"2002","journal-title":"Ophthalmology"},{"key":"R32-20250528","doi-asserted-by":"crossref","first-page":"568","DOI":"10.1016\/j.clae.2020.03.009","article-title":"Do visual performance and optical quality vary across different contact lens correction modalities in keratoconus?","volume":"43","author":"Kumar","year":"2020","journal-title":"Contact Lens Anterior Eye"},{"key":"R33-20250528","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1016\/j.ophtha.2009.06.039","article-title":"Shifting of the line of sight in keratoconus measured by a Hartmann-Shack sensor","volume":"117","author":"Mihaltz","year":"2010","journal-title":"Ophthalmology"},{"key":"R34-20250528","doi-asserted-by":"crossref","first-page":"598","DOI":"10.1016\/j.clae.2019.04.012","article-title":"Optical considerations for scleral contact lenses: A review","volume":"42","author":"Vincent","year":"2019","journal-title":"Contact Lens Anterior Eye"},{"key":"R35-20250528","doi-asserted-by":"crossref","first-page":"314","DOI":"10.1097\/OPX.0b013e318288d19c","article-title":"Wavefront guided scleral lens prosthetic device for keratoconus","volume":"90","author":"Sabesan","year":"2013","journal-title":"Optom Vis Sci"}],"container-title":["Eye &amp; Contact Lens: Science &amp; Clinical Practice"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/ICL.0000000000001007","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,28]],"date-time":"2025-05-28T16:15:25Z","timestamp":1748448925000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/ICL.0000000000001007"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,6,2]]},"references-count":34,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.1097\/icl.0000000000001007","relation":{},"ISSN":["1542-2321"],"issn-type":[{"value":"1542-2321","type":"print"}],"subject":[],"published":{"date-parts":[[2023,6,2]]},"assertion":[{"value":"2023-04-30","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}