{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,22]],"date-time":"2026-04-22T18:42:50Z","timestamp":1776883370945,"version":"3.51.2"},"reference-count":23,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","funder":[{"name":"Fundacion ICAR","award":["Presbysim"],"award-info":[{"award-number":["Presbysim"]}]}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,2]]},"abstract":"<jats:sec>\n                    <jats:title>Objectives:<\/jats:title>\n                    <jats:p>To compare the visual performance and subjective satisfaction of four daily disposable multifocal contact lenses (MCLs) in presbyopic subjects. Likewise, a comparative analysis of the performance of symmetrical and asymmetrical near addition designs was performed.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>Twenty presbyopic participants were enrolled in this randomized crossover study evaluating short-term visual performance. The assessed outcomes included distance, intermediate, and near visual acuity (VA), defocus curves, contrast sensitivity function (CSF), stereopsis, and patient satisfaction measured by a visual analogue scale (VAS).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Significantly better distance VA was found for BioTrue compared with MyDay (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      =0.018). By contrast, near VA was significantly more limited with BioTrue compared with the rest of contact lenses (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      \u22640.036). No significant differences in CSF were found between MCLs (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &gt;0.05). Asymmetrical designs showed better stereopsis than symmetrical designs (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      \u22640.018). VAS scale showed a nonsignificant trend to better scores for symmetrical designs for distance vision, and the opposite for near vision (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &gt;0.05).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>Daily disposable MCLs demonstrated satisfactory short-term performance, although design differences should guide individualized selection to optimize visual outcomes. Notably, asymmetrical lens designs did not compromise stereopsis and may offer superior near VA compared with symmetrical alternatives.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/icl.0000000000001237","type":"journal-article","created":{"date-parts":[[2025,11,12]],"date-time":"2025-11-12T18:03:07Z","timestamp":1762970587000},"page":"55-61","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["Comparative Analysis of Short-Term Visual Performance of Four Daily Simultaneous Vision Center-Near Multifocal Contact Lenses"],"prefix":"10.1097","volume":"52","author":[{"given":"Ainhoa","family":"Molina-Mart\u00edn","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Elena","family":"Mart\u00ednez-Plaza","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kevin","family":"Mena-Guevara","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dolores","family":"de Fez","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Violeta","family":"G\u00f3mez-Vicente","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David P.","family":"Pi\u00f1ero","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2025,11,12]]},"reference":[{"key":"R1-20260123","doi-asserted-by":"crossref","first-page":"323","DOI":"10.1016\/j.clae.2017.03.010","article-title":"Presbyopic and non-presbyopic contact lens opinions and vision correction preferences","volume":"40","author":"Rueff","year":"2017","journal-title":"Cont Lens Anterior Eye"},{"key":"R2-20260123","first-page":"22","article-title":"International contact lens prescribing in 2024","volume":"40","author":"Morgan","year":"2025","journal-title":"Contact Lens Spectr"},{"key":"R3-20260123","first-page":"26","article-title":"International contact lens prescribing in 2011","volume":"27","author":"Morgan","year":"2012","journal-title":"Contact Lens Spectr"},{"key":"R4-20260123","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1111\/j.1444-0938.2012.00773.x","article-title":"An international survey of daily disposable contact lens prescribing","volume":"96","author":"Efron","year":"2013","journal-title":"Clin Exp Optom"},{"key":"R5-20260123","doi-asserted-by":"crossref","first-page":"253","DOI":"10.1111\/j.1444-0938.2010.00488.x","article-title":"A 'cost-per-wear' model based on contact lens replacement frequency","volume":"93","author":"Efron","year":"2010","journal-title":"Clin Exp Optom"},{"key":"R6-20260123","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1016\/j.clae.2012.10.073","article-title":"Daily disposable lenses: The better alternative","volume":"36","author":"Cho","year":"2013","journal-title":"Cont Lens Anterior Eye"},{"key":"R7-20260123","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1016\/j.clae.2008.01.005","article-title":"Prescribing daily disposable contact lenses in the UK","volume":"31","author":"Efron","year":"2008","journal-title":"Cont Lens Anterior Eye"},{"key":"R8-20260123","doi-asserted-by":"crossref","first-page":"102158","DOI":"10.1016\/j.clae.2024.102158","article-title":"BCLA CLEAR presbyopia: Management with contact lenses and spectacles","volume":"47","author":"Morgan","year":"2024","journal-title":"Cont Lens Anterior Eye"},{"key":"R9-20260123","doi-asserted-by":"crossref","first-page":"102348","DOI":"10.1016\/j.clae.2024.102348","article-title":"International trends in prescribing multifocal and monovision soft contact lenses to correct presbyopia (2000-2023): An update","volume":"48","author":"Morgan","year":"2025","journal-title":"Cont Lens Anterior Eye"},{"key":"R10-20260123","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1111\/cxo.12488","article-title":"Soft multifocal simultaneous image contact lenses: A review","volume":"100","author":"P\u00e9rez-Prados","year":"2017","journal-title":"Clin Exp Optom"},{"key":"R11-20260123","doi-asserted-by":"crossref","first-page":"417","DOI":"10.1111\/j.1475-1313.2007.00488.x","article-title":"Monovision: A review","volume":"27","author":"Evans","year":"2007","journal-title":"Ophthalmic Physiol Opt"},{"key":"R12-20260123","doi-asserted-by":"crossref","first-page":"1096","DOI":"10.1097\/OPX.0000000000001311","article-title":"Visual performance of daily-disposable multifocal soft contact lenses: A randomized, double-blind clinical trial","volume":"95","author":"Sha","year":"2018","journal-title":"Optom Vis Sci"},{"issue":"Suppl 2","key":"R13-20260123","doi-asserted-by":"crossref","first-page":"S157","DOI":"10.1097\/ICL.0000000000000430","article-title":"Comparison of extended depth-of-focus prototype contact lenses with the 1-day Acuvue Moist multifocal after one week of wear","volume":"44","author":"Sha","year":"2018","journal-title":"Eye Contact Lens"},{"key":"R14-20260123","doi-asserted-by":"crossref","first-page":"157","DOI":"10.2147\/OPTO.S462723","article-title":"Relationships between success factors in daily disposable multifocal contact lenses","volume":"16","author":"Guthrie","year":"2024","journal-title":"Clin Optom (Auckl)"},{"key":"R15-20260123","doi-asserted-by":"crossref","first-page":"e40137","DOI":"10.1016\/j.heliyon.2024.e40137","article-title":"Randomised controlled trial of HOYA one-day multifocal contact lenses: The HOMCL trial","volume":"10","author":"Evans","year":"2024","journal-title":"Heliyon"},{"key":"R16-20260123","doi-asserted-by":"crossref","first-page":"102105","DOI":"10.1016\/j.clae.2023.102105","article-title":"Multifocal contact lens success predictability","volume":"47","author":"Lazon de la Jara","year":"2024","journal-title":"Cont Lens Anterior Eye"},{"key":"R17-20260123","doi-asserted-by":"crossref","first-page":"175","DOI":"10.1016\/j.clae.2017.10.002","article-title":"Disability glare in soft multifocal contact lenses","volume":"41","author":"Wahl","year":"2018","journal-title":"Cont Lens Anterior Eye"},{"key":"R18-20260123","doi-asserted-by":"crossref","first-page":"342","DOI":"10.1097\/OPX.0000000000001874","article-title":"Contrast sensitivity with center-distance multifocal soft contact lenses","volume":"99","author":"Nti","year":"2022","journal-title":"Optom Vis Sci"},{"key":"R19-20260123","doi-asserted-by":"crossref","first-page":"101440","DOI":"10.1016\/j.clae.2021.03.007","article-title":"Impact of the pupil size\u2014Central optical zone diameter relationship on visual performance in aspheric multifocal contact lenses","volume":"45","author":"Talens-Estarelles","year":"2022","journal-title":"Cont Lens Anterior Eye"},{"key":"R20-20260123","doi-asserted-by":"crossref","first-page":"e117","DOI":"10.1097\/ICL.0000000000001149","article-title":"Impact on distance and near contrast sensitivity of multifocal contact lenses: A systematic review","volume":"51","author":"Mena-Guevara","year":"2025","journal-title":"Eye Contact Lens"},{"key":"R21-20260123","doi-asserted-by":"crossref","first-page":"154","DOI":"10.1111\/aos.12487","article-title":"Contrast sensitivity measured by two different test methods in healthy, young adults with normal visual acuity","volume":"93","author":"Koefoed","year":"2015","journal-title":"Acta Ophthalmol"},{"key":"R22-20260123","doi-asserted-by":"crossref","first-page":"619","DOI":"10.1097\/00006324-198808000-00005","article-title":"Stereopsis in presbyopes wearing monovision and simultaneous vision bifocal contact lenses","volume":"65","author":"McGill","year":"1988","journal-title":"Am J Optom Physiol Opt"},{"key":"R23-20260123","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1016\/0141-7037(90)80012-Q","article-title":"Theoretical and practical factors influencing the optical performance of contact lenses for the presbyope","volume":"13","author":"Charman","year":"1990","journal-title":"J Br Contact Lens Assoc"}],"container-title":["Eye &amp; Contact Lens: Science &amp; Clinical Practice"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/ICL.0000000000001237","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,23]],"date-time":"2026-01-23T05:00:21Z","timestamp":1769144421000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/ICL.0000000000001237"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,11,12]]},"references-count":23,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/icl.0000000000001237","relation":{},"ISSN":["1542-233X"],"issn-type":[{"value":"1542-233X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,11,12]]},"assertion":[{"value":"2025-10-20","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}