{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T23:40:22Z","timestamp":1787010022340,"version":"build-2736575974"},"reference-count":32,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"8","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019,8]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>To evaluate the changes in anterior corneal topography induced by short-time wear of scleral contact lenses (SLs) in keratoconic subjects with and without a history of corneal cross-linking (CXL).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>Nine keratoconic patients (14 eyes) were fitted with 18.5 mm SLs for optical rehabilitation. Subjects were divided into 2 groups: 7 eyes without a history of CXL (Non-CXL group) and 7 with a history of CXL (CXL group). Corneal topography was performed at baseline and after 2 and 5 hours of lens wear. The differences for simulated flat (Kflat), steep (Ksteep) and maximal (Kmax) corneal curvatures, central corneal astigmatism (CCA), and central cornea thickness were evaluated.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      No statistically significant difference was detected between Non-CXL and CXL groups in any of these measures. Statistically significant flattening was detected in Ksteep Repeated measures analysis of variance ([RM-ANOVA), F (2,24) = 11.32,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.0001], CCA [RM-ANOVA, F (2,24) = 15.34,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.0001], and Kmax [RM-ANOVA, F (2,24) = 19.10,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.0001). From baseline to 5 hours of SL wear, Ksteep decreased on average from 53.1 to 52.4 D, Kmax decreased from 56.7 to 55.8 D, and CCA decreased from 7.2 to 6.3 D. Kmax showed a trend toward more flattening in the Non-CXL group. Central cornea thickness showed significant thickening over time from baseline (451 \u03bcm) to 5 hours (458 \u03bcm) of SL wear [RM-ANOVA, F (1,12) = 319.3,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.0001].\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>Short-term scleral lens wear in keratoconic patients may cause flattening of the anterior cornea. A history of CXL treatment does not guarantee corneal shape stability after scleral lens wear. Practitioners should be aware of these changes because scleral lens wear may mask the signs of keratoconus progression.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/ico.0000000000002008","type":"journal-article","created":{"date-parts":[[2019,5,24]],"date-time":"2019-05-24T23:11:47Z","timestamp":1558739507000},"page":"986-991","source":"Crossref","is-referenced-by-count":14,"title":["Effect of Scleral Lenses on Corneal Topography in Keratoconus: A Case Series of Cross-Linked Versus Non\u2013Cross-Linked Eyes"],"prefix":"10.1097","volume":"38","author":[{"given":"Boris","family":"Severinsky","sequence":"first","affiliation":[{"name":"Emory Eye Center, Department of Ophthalmology, Emory University School of Medicine, Atlanta, GA;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daddi","family":"Fadel","sequence":"additional","affiliation":[{"name":"Il Punto di Vista, Private Practice, Rome, Italy;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jenya","family":"Davelman","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Hadassah Medical Center (HMC), Hebrew University, Jerusalem, Israel;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eric","family":"Moulton","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Boston Children's Hospital, Harvard Medical School, Boston, MA; and"},{"name":"Department of Anesthesiology, Critical Care and Pain Medicine, Boston, MA."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2019,5,21]]},"reference":[{"key":"R1-20230912","doi-asserted-by":"crossref","first-page":"158","DOI":"10.1016\/S0141-7037(83)80064-0","article-title":"Gas permeable haptic lenses","volume":"6","author":"Ezekiel","year":"1983","journal-title":"J Br Contact Lens Assoc."},{"key":"R2-20230912","doi-asserted-by":"crossref","first-page":"318","DOI":"10.1016\/S0002-9394(14)74558-1","article-title":"A gas-permeable scleral contact lens for visual rehabilitation","volume":"109","author":"Schein","year":"1990","journal-title":"Am J Ophthalmol."},{"key":"R3-20230912","doi-asserted-by":"crossref","first-page":"308","DOI":"10.1097\/00003226-200305000-00006","article-title":"Scleral contact lenses may help where other modalities fail","volume":"22","author":"Segal","year":"2003","journal-title":"Cornea"},{"key":"R4-20230912","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1097\/01.icl.0000233217.68379.d5","article-title":"Modern scleral lenses part I: clinical features","volume":"33","author":"Visser","year":"2007","journal-title":"Eye Contact Lens."},{"key":"R5-20230912","doi-asserted-by":"crossref","first-page":"518","DOI":"10.1097\/00003226-199211000-00006","article-title":"Treatment of ocular surface disorders and dry eyes with high gas-permeable scleral lenses","volume":"11","author":"Otten","year":"1992","journal-title":"Cornea"},{"key":"R6-20230912","doi-asserted-by":"crossref","first-page":"501","DOI":"10.1097\/00003226-200007000-00020","article-title":"Factors associated with corneal scarring in the collaborative longitudinal evaluation of keratoconus (CLEK) study","volume":"19","author":"Barr","year":"2000","journal-title":"Cornea"},{"key":"R7-20230912","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1016\/S0161-6420(99)00027-5","article-title":"The effects of long-term contact lens wear on corneal thickness, curvature, and surface regularity","volume":"107","author":"Liu","year":"2000","journal-title":"Ophthalmology"},{"key":"R8-20230912","doi-asserted-by":"crossref","first-page":"236","DOI":"10.1046\/j.1475-1313.2001.00556.x","article-title":"Rigid gas permeable contact lens and corneal topography","volume":"21","author":"Yebra-Pimentel","year":"2001","journal-title":"Ophthalmic Physiol Opt."},{"key":"R9-20230912","doi-asserted-by":"crossref","first-page":"2290","DOI":"10.1016\/j.jcrs.2004.05.021","article-title":"Predicting time to refractive stability after discontinuation of rigid contact lens wear before refractive surgery","volume":"30","author":"Tsai","year":"2004","journal-title":"J Cataract Refract Surg."},{"key":"R10-20230912","doi-asserted-by":"crossref","first-page":"461","DOI":"10.1016\/j.clae.2014.08.002","article-title":"Corneal changes following short-term miniscleral contact lens wear","volume":"37","author":"McLeod","year":"2014","journal-title":"Cont Lens Anterior Eye"},{"key":"R11-20230912","doi-asserted-by":"crossref","first-page":"100","DOI":"10.1111\/opo.12270","article-title":"Miniscleral lens wear influences corneal curvature and optics","volume":"36","author":"Vincent","year":"2016","journal-title":"Ophth Physiol Opt."},{"key":"R12-20230912","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1097\/OPX.0000000000000803","article-title":"Hypoxic corneal changes following eight hours of scleral contact lens wear","volume":"93","author":"Vincent","year":"2016","journal-title":"Optom Vis Sci."},{"key":"R13-20230912","doi-asserted-by":"crossref","first-page":"70","DOI":"10.1016\/j.clae.2018.06.005","article-title":"Anterior eye surface changes following miniscleral contact lens wear","volume":"42","author":"Consejo","year":"2019","journal-title":"Cont Lens Anterior Eye"},{"key":"R14-20230912","doi-asserted-by":"crossref","first-page":"294","DOI":"10.1016\/j.clae.2015.03.006","article-title":"Scleral lens influence on corneal curvature and pachymetry in keratoconus patients","volume":"38","author":"Soeters","year":"2015","journal-title":"Cont Lens Anterior Eye"},{"key":"R15-20230912","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1016\/j.clae.2018.04.200","article-title":"Posterior cornea and thickness changes after scleral lens wear in keratoconus patients","volume":"42","author":"Serramito","year":"2019","journal-title":"Cont Lens Anterior Eye"},{"key":"R16-20230912","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1097\/ICL.0000000000000534","article-title":"Anterior corneal curvature and aberration changes after scleral lens wear in keratoconus patients with and without ring segments","volume":"45","author":"Serramito-Blanco","year":"2019","journal-title":"Eye Contact Lens."},{"key":"R17-20230912","doi-asserted-by":"crossref","first-page":"620","DOI":"10.1016\/S0002-9394(02)02220-1","article-title":"Riboflavin\/ultraviolet-A\u2013induced collagen crosslinking for the treatment of keratoconus","volume":"135","author":"Wollensak","year":"2003","journal-title":"Am J Ophthalmol."},{"key":"R18-20230912","doi-asserted-by":"crossref","first-page":"691","DOI":"10.1016\/j.jcrs.2010.10.052","article-title":"Corneal thickness changes after corneal collagen crosslinking for keratoconus and corneal ectasia: one-year results","volume":"37","author":"Greenstein","year":"2011","journal-title":"J Cataract Refract Surg."},{"key":"R19-20230912","doi-asserted-by":"crossref","first-page":"456","DOI":"10.1016\/S0886-3350(98)80284-8","article-title":"Live-epikeratophakia for keratoconus","volume":"24","author":"Krumeich","year":"1998","journal-title":"J Cataract Refract Surg."},{"key":"R20-20230912","doi-asserted-by":"crossref","first-page":"321","DOI":"10.1016\/j.clae.2018.02.003","article-title":"The influence of limbal and scleral shape on scleral lens design","volume":"41","author":"Fadel","year":"2018","journal-title":"Cont Lens Anterior Eye."},{"key":"R21-20230912","doi-asserted-by":"crossref","first-page":"233","DOI":"10.3109\/08820538.2010.518873","article-title":"Technological advances shaping scleral lenses: the Boston ocular surface prosthesis in patients with glaucoma tubes and trabeculectomies","volume":"25","author":"Tanhehco","year":"2010","journal-title":"Semin Ophthalmol."},{"key":"R22-20230912","doi-asserted-by":"crossref","first-page":"452","DOI":"10.3928\/1081597X-20110106-01","article-title":"Detection of biomechanical changes after corneal cross-linking using Ocular Response Analyzer software","volume":"27","author":"Spoerl","year":"2011","journal-title":"J Refract Surg."},{"key":"R23-20230912","doi-asserted-by":"crossref","first-page":"1780","DOI":"10.1016\/S0886-3350(03)00407-3","article-title":"Stress-strain measurements of human and porcine corneas after riboflavin-ultraviolet-A-induced cross-linking","volume":"29","author":"Wollensak","year":"2003","journal-title":"J Cataract Refract Surg."},{"key":"R24-20230912","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1016\/S0141-7037(88)80006-5","article-title":"Corneal response to gas-permeable impression scleral lenses","volume":"11","author":"Bleshoy","year":"1988","journal-title":"J Br Contact Lens Assoc."},{"key":"R25-20230912","doi-asserted-by":"crossref","first-page":"475","DOI":"10.1046\/j.1475-1313.1999.00470.x","article-title":"The cornea swells in the posterior direction under hydrogel contact lenses","volume":"19","author":"Erickson","year":"1999","journal-title":"Ophthalmic Physiol Opt."},{"key":"R26-20230912","doi-asserted-by":"crossref","first-page":"457","DOI":"10.3109\/02713688109019986","article-title":"Non-uniform swelling properties of the corneal stroma","volume":"1","author":"Lee","year":"1981","journal-title":"Curr Eye Res."},{"key":"R27-20230912","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1097\/00006324-200403000-00011","article-title":"Contact lens-induced corneal swelling and surface changes measured with the Orbscan II corneal topographer","volume":"81","author":"Moezzi","year":"2004","journal-title":"Optom Vis Sci."},{"key":"R28-20230912","doi-asserted-by":"crossref","first-page":"803","DOI":"10.3928\/1081597X-20160629-01","article-title":"Detection of keratoconus with a new biomechanical index","volume":"32","author":"Vinciguerra","year":"2016","journal-title":"J Refract Surg."},{"key":"R29-20230912","doi-asserted-by":"crossref","first-page":"1213","DOI":"10.1016\/j.jcrs.2017.07.021","article-title":"New perspectives on the detection and progression of keratoconus","volume":"43","author":"Martinez-Abad","year":"2017","journal-title":"J Cataract Refract Surg."},{"key":"R30-20230912","doi-asserted-by":"crossref","first-page":"152","DOI":"10.1097\/ICL.0000000000000523","article-title":"Scleral lens issues and complications related to a nonoptimal fitting relationship between the lens and ocular surface","volume":"45","author":"Fadel","year":"2019","journal-title":"Eye Contact Lens"},{"key":"R31-20230912","doi-asserted-by":"crossref","first-page":"230","DOI":"10.1097\/ICL.0000000000000266","article-title":"Influence of apical clearance on mini-scleral lens settling, clinical performance, and corneal thickness changes","volume":"43","author":"Esen","year":"2017","journal-title":"Eye Contact Lens."},{"key":"R32-20230912","doi-asserted-by":"crossref","first-page":"150","DOI":"10.1016\/S1888-4296(10)70022-4","article-title":"Current applications and efficacy of scleral contact lenses\u2013a retrospective study","volume":"3","author":"Severinsky","year":"2010","journal-title":"J Optom."}],"container-title":["Cornea"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00003226-201908000-00012","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,12]],"date-time":"2023-09-12T14:56:22Z","timestamp":1694530582000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00003226-201908000-00012"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,5,21]]},"references-count":32,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2019]]}},"URL":"https:\/\/doi.org\/10.1097\/ico.0000000000002008","relation":{},"ISSN":["0277-3740"],"issn-type":[{"value":"0277-3740","type":"print"}],"subject":[],"published":{"date-parts":[[2019,5,21]]}}}